Fire alarm replacement
Forecast New Requirement Updated
- Agency
-
Federal Law Enforcement Training Center
Department of Homeland Security
- Solicitation expected
- Estimated value
- $2,000,000 to $5,000,000
- Set-aside
- Total Small Business
Forecast facts
- Anticipated award
- Through
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- charleston, SC
- Forecast number
- F2026074090
- Points of contact
Forecast details come from DHS's Acquisition Planning Forecast System. Agencies' dates and values are estimates.
About this forecast
The Department of Homeland Security Federal Law Enforcement Training Center is procuring labor, materials, equipment, and supervision to replace existing fire alarm systems and install new Notifier systems across multiple buildings at its Charleston, South Carolina campus in compliance with NFPA 101 life safety occupancy standards. The scope includes abandoning old SLC/NAC wiring in place where noted, installing new SLC and NAC communication cabling, and connecting all systems to Notifier CLSS (Connected Life Safety Services) and Central Station Monitoring Software with Gateway/Pathway communication devices to meet building-specific compatibility requirements. Solicitation release is estimated for November 2, 2026, with award anticipated January 8, 2027.
The estimated award value ranges from $2 million to $5 million under a Firm Fixed Price contract vehicle set aside for Total Small Business, with performance of work at the Federal Law Enforcement Training Center in Charleston, South Carolina and an estimated period of performance running from January 8, 2027 through January 7, 2028. Contracting Officer Aubreigh Sumner (aubreigh.b.sumner@fletc.dhs.gov, 843-745-2761), Lead Project Manager Matt Hernandez (matthew.j.hernandez@fletc.dhs.gov, 843-566-8557), and Small Business Specialist Allan Gray (allan.w.gray@fletc.dhs.gov, 912-531-7038) serve as primary points of contact.
Forecast text
Provide all labor, materials, equipment, and supervision to replace existing fire alarm systems and associated devices/wiring, and commission new Notifier systems in accordance with NFPA 101 life safety occupancy standards. Abandon old SLC/NAC wiring in place where noted and install new SLC and NAC communication cabling/wiring. Connect all systems to the Notifier CLSS (Connected Life Safety Services) and Central Station Monitoring Software utilizing Gateway/Pathway communication devices, meeting building-specific compatibility requirements. This work will include several buildings at the Federal law Enforcement Training Center (FLETC) Charleston, SC.