DB PJKK USMS Modernize Prisoner Elevator, Prince Jonah Kalanianaole Kuhio (PJKK) Federal Building, 300 Ala Moana Blvd. , Honolulu, HI 96850-4118

Forecast New Requirement Updated

Agency
Solicitation expected
Not on record
Estimated value
$251,000 to $500,000
Set-aside
Total Small Business

Forecast facts

Anticipated award
Not on record
Acquisition strategy
Pre-existing Contract Vehicle - Order - Indefinite Delivery Indefinite Quantity (IDIQ) or BPA
NAICS code
236220 Commercial and Institutional Building Construction
Place of performance
Honolulu, HI
Forecast number
17515
Points of contact

Forecast details come from the GSA Acquisition Gateway. Agencies' dates and values are estimates.

About this forecast

The General Services Administration (GSA) Public Buildings Service is seeking an elevator contractor to provide a turnkey and code-compliant elevator replacement for the Prince Jonah Kalanianaole Kuhio (PJKK) Federal Building in Honolulu, Hawaii. The contract will require the contractor to design and install a custom elevator, including new surveillance camera, scramble pad, and intercom with duress features, while retaining the existing car enclosure and finishes.

The contract is set aside for small businesses and will require the contractor to field verify all existing conditions and ensure the new elevator design is compatible with the building's existing electrical and structural constraints. The scope of work includes all necessary supervision, professional design services, labor, materials, and equipment to complete the project as outlined in the Statement of Work.

Forecast text

Elevator Contractor shall provide a turn-key and Code compliant elevator replacement.  The new elevator requires custom design and may require building modifications.  Include all required work.

Retain existing finishes and car enclosure.  Provide new surveillance camera in front portion of car. Provide scramble pad required to activate car buttons. Provide intercom with duress feature. Surveillance camera shall operate during normal mode and security mode.  Intercom and duress shall operate during normal mode and security mode.  Scramble pad shall be operative on normal mode only.

Design equipment to fit within existing hoistway, pit, machine room, overhead dimensions and other existing constraints.

Design for compatibility with existing electrical provisions. Field verify prior to bid date. Contractor is responsible for existing power supply including power feeders and all modifications for compatibility with new equipment, retained equipment and code compliance.

The Contractor shall provide all supervision, professional design services, labor, material and equipment necessary to perform the specified tasks as described on the Statement of Work (SOW).