DB PJKK Modernize Halekauwila Elevators

Forecast New Requirement Updated

Agency
Solicitation expected
Not on record
Estimated value
Up to $5,000,000
Set-aside
Total Small Business

Forecast facts

Anticipated award
Not on record
Acquisition strategy
Pre-existing Contract Vehicle - Order - Indefinite Delivery Indefinite Quantity (IDIQ) or BPA
NAICS code
236220 Commercial and Institutional Building Construction
Place of performance
Honolulu, HI
Forecast number
22820
Points of contact

Forecast details come from the GSA Acquisition Gateway. Agencies' dates and values are estimates.

About this forecast

The General Services Administration (GSA) Public Buildings Service is seeking a contractor to modernize the elevators at the Halekauwila Building in Honolulu, Hawaii. The key requirements include installing new gearless AC VVVF Traction systems, new door operators and associated components, and providing new car finishes and features. The contractor must also weigh the car and counterweight of elevator #1 prior to the work.

The contract is set aside for small businesses and the work is expected to include a range of installation, replacement, and modernization tasks. The place of performance is Honolulu, Hawaii, but details on the estimated contract value or duration were not provided in the forecast.

Forecast text

The Contractor shall provide all supervision, labor, materials and equipment required to:

 • Install new gearless AC VVVF Traction with new secondary and deflector sheaves, as necessary. Locate deflector sheaves in the elevator machine room and provide Machine Beams and Blocking Beams as required. Paint pinch points in bright color. Provide guards per ASME A17.1. Remove existing hoist machines. Provide “Stop” switches on new hoist machine if there is no line of sight to the main line disconnect switches.

* Provide Emergency Brake incorporated in and integral with the new hoist machine to protect against ascending car overspeed and unintended motion.

* Provide new Closed-Loop GAL or MAC door operators, new interlocks, heat resistant interlock wiring, new door restrictors, new car and hoistway door hangers and tracks, and new door closers.

* Retain existing finishes and car enclosure. Provide new 48" toe guard, standard railing for car tops when required by ASME A17.1. Also, provide Elevator Identification Number on car crosshead per code. Replace car fan with new 3-speed exhaust blower. Install mounting provisions and wiring for future installations of card readers and surveillance cameras.

Weigh car and counterweight of elevator #1 prior to field work, document weight to GSA.

On GovTribe

Work this forecast

  • Track it in your pipeline
  • Find teaming partners
  • Similar forecasts
  • Ask GovTribe AI about this forecast