Wolf Creek, Cordell Hull, & Old Hickory Power Plants: VCB Repair
Closed Pre-Solicitation Posted
- Solicitation number
- W912p526TKDB4
- Agency
-
ENDIST Nashville
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- Jamestown, Kentucky 42629, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Corps of Engineers, Nashville District, is conducting market research through a Request for Information to establish a competitive basis for refurbishing and delivering three Eaton 150VCP-WG-50-3000A Vacuum Circuit Breakers (VCBs) to Cordell Hull, Wolf Creek, and Old Hickory Power Plants, with RFI responses due by 1:00 PM Central Time on June 24, 2026. No set-aside is anticipated.
The work requires furnishing all labor, tools, materials, and Eaton-approved test equipment necessary to refurbish government-owned VCBs that have been provided to Eaton for evaluation and recommended refurbishment. Following refurbishment, the contractor shall return the three breakers to their respective power plants. The breakers must be compatible with existing USACE switchgear. The contractor must be a Certified Eaton Repair Facility.
Performance occurs at three locations: Cordell Hull Power Plant, Wolf Creek Power Plant, and Old Hickory Power Plant. The procurement is classified under PSC Z1MD (Maintenance of EPG Facilities - Hydro) and NAICS 238210 (Electrical Contractors and Other Wiring Installation Contractors), with a $19 million size standard.
Responses should include firm name, CAGE code, point of contact with phone and email, and certification status as a Certified Eaton Repair Facility. Submit responses to Kerri Broglin at Kerri.D.Broglin@usace.army.mil. This is market research only; the requirement is subject to change or elimination.
Notice text
REQUEST FOR INFORMATION
The Government is issuing this Request for Information to determine a competitive basis for the procurement described. This is not a solicitation. No reimbursement will be made for any costs associated with providing information in response to this survey.
This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.
Requirement: The work shall consist of furnishing all labor, tools, materials, and Eaton approved test equipment necessary torefurbish and deliver a total of three (3) total Eaton 150VCP-WG-50-3000A Vacuum Circuit Breakers (VCB), property of the US Government, to Cordell Hull, Wolf Creek, and Old Hickory respectively. The VCBs have been provided to Eaton for evaluation and recommended refurbishment. Following final refurbishment, the contractor shall return three (3) Eaton 150VCP-WG50-3000A VCB to Cordell Hull Power Plant, Wolf Creek Power Plant, and Old Hickory Power Plant as described below. The breaker must be compatible with existing USACE switchgear.
The contractor will be required to provide all plant, labor and materials to complete the project.
- PSC Z1MD Maintenance of EPG Facilities - Hydro NAICS 238210 Electrical Contractors and Other Wiring Installation Contractors, Size Standard $19M.
Survey: The Government is issuing this notice to determine a competitive basis. This is not a solicitation and the items listed herein are subject to change or eliminated from the requirement. This survey is for market research purposes only. Only contractors capable of performing this type of work should respond to this Request for Information.
Your response to this survey is requested by 1:00 PM Central Time Wednesday, June 24, 2026. Please send by email to Kerri Broglin at Kerri.D.Broglin@usace.army.mil
- Name of your firm:
- CAGE:
- Point of Contact, Phone number and EMAIL address:
- Are you a Certified Eaton Repair Facility:
- Please provide responses to the following:
1) List three (3) projects completed within ten (10) years of the date of this notice that demonstrates experience, as a prime contractor or subcontractor, constructing gantry cranes with capacities exceeding 100 tons.
(a) Project Name:
Contract Number (if applicable):
Year Completed:
Prime Contractor or Sub-Contractor:
Type and percentage of work self-performed (based on contract value):
Dollar Amount:
General Description of project:
(b) Project Name:
Contract Number (if applicable):
Year Completed:
Prime Contractor or Sub-Contractor:
Type and percentage of work self-performed (based on contract value):
Dollar Amount:
General Description of project:
(c) Project Name:
Contract Number (if applicable):
Year Completed:
Prime Contractor or Sub-Contractor:
Type and percentage of work self-performed (based on contract value):
Dollar Amount:
General Description of project:
- Are you a Small Business classified under the above NAICS code? If so, do you fall into a sub-category (e.g. HubZone, 8(a), SDVOSB, WOSB, etc.)?
- If this requirement is advertised, do you anticipate submitting a quote?
Please provide any additional information you feel is necessary:
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| High Voltage Power Supplies (HVPS) for Electronic Fish Barriers | ENDIST Chicago | No set-aside | |
| Tenkiller Hydropower Excitation System Replacement | ENDIST Tulsa | No set-aside | |
| Eufaula Powerhouse Hydroelectric Generator Rewind | ENDIST Tulsa | No set-aside | |
| Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT | ENDIST New England | Total Small Business | |
| J061--intent to sole source award to eaton corp - base year maintenance and service contract for 8 UPS hershel woody williams VAMC | Veterans Integrated Service Network 5 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity