Water-cooler condensator and pre-assem evaporator brand name or equal to change RFQ due date 16 september 2014 1200 noon EST and questions pertaining to the solicitation due 12 september 2014 1200 noon EST
Award Notice Posted
- Solicitation number
- W81XWH14T0512
- Agency
-
Medical Command
Department of the Army, Department of Defense
- Awarded
- to United Refrigeration Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- W81XWH14P0641 Federal contract award
- NAICS code
- 333415 Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
- PSC
- Not on record
- Place of performance
- US Army Medical Research Acquisition Activity Attn: Mcmr-AAA, 820 Chandler Street Frederick MD 21702 US
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Solicitation No: W81XWH-14-T-0512 will be issued on 11 September 2014 and quotes will be due on 16 September 2014 @ 12:00 PM EST. The Government requirement is to provide quantity of 1 Unit of Water Cooler Evaporator Cond Compressor Circuit Breaker, Suction Accumulator with Heat Exchanger, Suction Filted (Sealed Type) Water Regulating Valve. Manufacturer Keeprite Refrigeration W0075L6ISSA/208-230/1/60. Equipment Walk-in Measurement 4' x 4' with holding temperature of +4 Degrees. Trenton Pre-Assem Evap W/PSC L/T R404A 230V TPLP105LES2BBR6 for use with R404A Only. Please follow what the requirement will be according to the Minimal Essential Characteristics (MEC). This requirement will be lowest price technically accepted (LPTA) for a Keeprite and Trenton brand name or equal. The establish Purchase Order (NAICS) code for this procurement is 333415 with a size standard of 750. Delivery is to be made U. S. Army Medical Research Institute of Infectious Diseases, Fort Detrick, MD 21702. There will not be any hard copies of the solicitation are issued by this contracting office. All interested parties can view, download and print a copy of the solicitation, attachments (MECS), and any resulting amendments. View Additional Solicitation on the ASFI website. All responsible sources may submit a quote, which shall be considered by the agency. The competitive solicitation, solicitation amendments and all questions and answers relating to this procurement shall be made available via the Internet at http://www.fedbizops.gov. In accordance with FARS 13.5, all contractors wishing to do business with the Department of Defense must be registered in the System for Award Management registration (SAM) can be accomplished at the following website: www.sam.gov. This procurement is for unrestricted. Quotes will be evaluated on a Commercial Firm Fixed Price and any resulting contract will be issued as a Firm Fixed Price Award. All questions relating to this procurement shall be submitted NTL: 12 September 2014 @ 12:00 PM EST for answer/s. Telephone request will not be honored and bidder lists will not be maintained. POC for this action is Wanda King at wanda.d.king@us.army.mil.
MEC PRE- ASSEM- EVAPORATOR
The unit should be compatible or equivalent to the following nomenclatures
Must use R 404 refrigerant.
Must include mounted & wired TXV, Liquid line Solenoid and defrost heater.
Must include a Thermostat.
Unit must operate at 208-230 volts single phase at 60 Hz.
Must have dimensions not exceeding 30 1/4 quote mark Wide , 15 quote mark Depth and 15-7/8 quote mark Height
Must be ratted to maintain a 4 degree C. box temperature with a capacity of 4,800 British thermal unit (BTU) and 950 CFM (Cubic Feet per Minute)
MEC WATER- COOLER CONDENSATOR
The unit should be compatible or equivalent to the following nomenclatures
Condensing unit must be water cooled and include the water regulating valve.
Must include a compressor, circuit breaker, suction accumulator, filter dryer and water cooled Heat Exchanger.
Unit must operate at 208-230 volts single phase at 60 Hz.
Must use R 404 refrigerant.
Must be ratted at 5,060 British thermal unit (BTU)
Update #1 ·
Solicitation No: W81XWH-14-T-0512 will be issued on 09 September 2014 and quotes will be due on 12 September 2014 @ 10:00 AM EST. The Government requirement is to provide quantity of 1 Unit of Water Cooler Evaporator Cond Compressor Circuit Breaker, Suction Accumulator with Heat Exchanger, Suction Filted (Sealed Type) Water Regulating Valve. Manufacturer Keeprite Refrigeration W0075L6ISSA/208-230/1/60. Equipment Walk-in Measurement 4' x 4' with holding temperature of +4 Degrees. Trenton Pre-Assem Evap W/PSC L/T R404A 230V TPLP105LES2BBR6 for use with R404A Only. Please follow what the requirement will be according to the Minimal Essential Characteristics (MEC). This requirement will be lowest price technically accepted (LPTA) for a Keeprite and Trenton brand name or equal. The establish Purchase Order (NAICS) code for this procurement is 333415 with a size standard of 750. Delivery is to be made U. S. Army Medical Research Institute of Infectious Diseases, Fort Detrick, MD 21702. There will not be any hard copies of the solicitation are issued by this contracting office. All interested parties can view, download and print a copy of the solicitation, attachments (MECS), and any resulting amendments. View Additional Solicitation on the ASFI website. All responsible sources may submit a quote, which shall be considered by the agency. The competitive solicitation, solicitation amendments and all questions and answers relating to this procurement shall be made available via the Internet at http://www.fedbizops.gov. In accordance with FARS 13.5, all contractors wishing to do business with the Department of Defense must be registered in the System for Award Management registration (SAM) can be accomplished at the following website: www.sam.gov. This procurement is for unrestricted. Quotes will be evaluated on a Commercial Firm Fixed Price and any resulting contract will be issued as a Firm Fixed Price Award. All questions relating to this procurement shall be submitted NTL: 10 September 2014 @ 10:00 AM EST for answer/s. Telephone request will not be honored and bidder lists will not be maintained. POC for this action is Wanda King at wanda.d.king@us.army.mil.
MEC PRE- ASSEM- EVAPORATOR
The unit should be compatible or equivalent to the following nomenclatures
Must use R 404 refrigerant.
Must include mounted & wired TXV, Liquid line Solenoid and defrost heater.
Must include a Thermostat.
Unit must operate at 208-230 volts single phase at 60 Hz.
Must have dimensions not exceeding 30 1/4 quote mark Wide , 15 quote mark Depth and 15-7/8 quote mark Height
Must be ratted to maintain a 4 degree C. box temperature with a capacity of 4,800 British thermal unit (BTU) and 950 CFM (Cubic Feet per Minute)
MEC WATER- COOLER CONDENSATOR
The unit should be compatible or equivalent to the following nomenclatures
Condensing unit must be water cooled and include the water regulating valve.
Must include a compressor, circuit breaker, suction accumulator, filter dryer and water cooled Heat Exchanger.
Unit must operate at 208-230 volts single phase at 60 Hz.
Must use R 404 refrigerant.
Must be ratted at 5,060 British thermal unit (BTU)