Vertical lineshaft pumps
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- W9127N26QA080
- Agency
-
ENDIST Portland
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 333914 Measuring, Dispensing, and Other Pumping Equipment Manufacturing
- PSC
- 4320 Power And Hand Pumps
- Place of performance
- Mill City, Oregon 97360, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers, Portland Engineering District, is conducting market research for vertical lineshaft pumps (PSC 4320, NAICS 333914) with a sources-sought response due May 13, 2026. This is not a formal solicitation but an informational canvass to assess industry capability and inform future procurement decisions.
USACE requires two identical vertical lineshaft pumps to replace a 30+ year-old drainage system at Big Cliff Powerhouse on the Santiam River, Oregon. The facility, which has operated since 1953, experienced recent pump failures that compromised automated drainage capability. Delivery is required to Detroit Dam in Mill City, Oregon, with restrictions to Monday–Thursday, 0700–1600 hours.
Technical specifications include 4-inch 150# ANSI 16.5 flange outlet, 75 GPM flow at 70 feet of head, continuously rising pump curve, 45-foot height from inlet to outlet centerline, 1-inch diameter stainless steel lineshaft in 5-foot sections, water-lubricated lineshaft bearings, bronze impellers, cast iron bowl, and basket strainers. Motors must be rated up to 3.0 horsepower with service factor of 1.15 or greater, powered by 3-phase 480V 60Hz supply at 1800 rpm or less. Pumped media consists of potentially silty water at temperatures ranging from 39 degrees Fahrenheit to 65 degrees Fahrenheit.
Vendors must submit capability statements and shop drawings with performance data sheets and pump curves. All business types are encouraged to respond, including small businesses, 8(a) firms, HUBZone, WOSB, EDWOSB, SDVOSB, and VOSB firms. No set-aside is anticipated. Estimated project cost is not disclosed.
Notice text
Sources Sought Number: W9127N26QA080
Subject: Sources Sought for vertical lineshaft pumps
PSC: 4320 - Power and Hand Pumps
NAICS: 333914 - Measuring, Dispensing, and Other Pumping Equipment Manufacturing
General. This Sources Sought is issued for informational and market research purposes only. It is not a Request for Proposal (RFP), Request for Quotation (RFQ), Invitation for Bid (IFB), or a solicitation under FAR Subpart 5.2.
The purpose of this Sources Sought is to obtain information regarding industry interest, capabilities, and qualifications so the Government can make informed acquisition decisions. We encourage responses from both large and small businesses, including Small Business, Small Disadvantaged Business, 8(a) firms, HUBZone firms, Woman-Owned Small Business (WOSB), Economically Disadvantaged Woman-Owned Small Business (EDWOSB), Service-Disabled Veteran-Owned Small Business (SDVOSB), and Veteran-Owned Small Business (VOSB). All interested parties are strongly encouraged to respond.
Responses to this Sources Sought will be used by the Government to support market research, assess available sources, and inform any future solicitation.
Please provide a capability statement demonstrating your ability to supply the requirement identified in the Performance Work Schedule (PWS). If you are unable to supply all of the listed items, please clearly identify any limitations in your capability statement.
This will help us accurately assess your qualifications for the full requirement.
Formal Sources Sought Response Due: 13 May 2026 at 12:00 PM PDT.
Project Background:
The U.S. Army Corps of Engineers (USACE) requires two (2) vertical lineshaft pumps for Big Cliff Powerhouse.
Outlet: 4” 150# ANSI 16.5 Flange compatible
Flow: 75 GPM at 70ft head
Static Head: 70 ft
Pump Curve: Continuously rising
Pump Formfactor: Vertical lineshaft with multistage impellers at inlet
Pump Height: 45’ from inlet to centerline of outlet flange
Lineshaft: 1” diameter, 5’ sections, 400 series stainless steel
Lineshaft Couplings: Coupling design capacity shall be the published manufacturer service rating divided by 1.5
Lineshaft Bearings: Water lubricated except for motor base bearing which may use oil or grease
Impeller Material: Bronze
Bowl Material: Cast Iron
Prelubrication: If needed, a prelubrication water line will be provided
Column Pipe: 5’ sections with flanged connections, 400 series stainless steel
Pumped Media: Potentially silty water, temperature ranging 39°-65° F
Filtering: Inlets must have basket strainers
Motors: Up to 3.0 hp with a service factor of 1.15 or greater
Motor Power Supply: 3 phase, 480 V, 60 hz circuit
Pump Speed: 1800 rpm or less
- Please read the PWS in its entirety to ensure a complete understanding of the requirement before responding to this Sources Sought.
Files
| File | Type | Posted |
|---|---|---|
| BCL Drainage Pumps Replacement - PWS.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Vertical lineshaft pumps | Award Notice | |
| Vertical lineshaft pumps | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Pump, centrifugal | Land and Maritime | No set-aside | |
| Pump unit, centrifug | Aviation | No set-aside | |
| Pump, MSW | Naval Supply Systems Command | No set-aside | |
| Pump unit, centrifugal | Land and Maritime | Total Small Business | |
| Pump, centrifugal | Land and Maritime | Total Small Business |
On GovTribe