The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Hood seeks a vapor generator for the SMART SEED Innovation Award project, with proposals due June 8, 2026.
The procurement is unrestricted (no set-aside). Place of performance is Dugway, Utah. The vapor generator must generate agent vapor at ultra-low concentrations down to 10 parts per billion to test and validate the sensitivity and response time of NDSI electronic vapor sensors across variable temperature and humidity conditions. The vendor must demonstrate ability to meet a defined testing matrix; this capability is mission-critical to validating sensor algorithms and performance data.
The generator must include a corrosive gas upgrade to protect internal components from corrosive chemical agents and simulants, a diffusion tube with membranes and gaskets, and a permeation tube kit. The NAICS code is 334516, Analytical Laboratory Instrument Manufacturing. The PSC code is 6630, Chemical Analysis Instruments.
Notice text
This procurement is mission-critical for the SMART SEED Innovation Award project, Vendor must demonstrat the ability to meet the requirements for this testing matrix. The testing threshold is agent vapor, with an objective to test at ultra-low concentrations (10 ppb).
The vapor generator is uniquely required because it provides the highly regulated, low concentration chemical vapor output necessary to accurately characterize the sensitivity and response time of the NDSI electronic vapor sensors under variable temperature and humidity conditions. Without this specific generation capability, DPG cannot confidently validate the
sensor algorithms or performance data.
To meet the specific demands of chemical agent testing and precisely control vapor generator output across the targeted ranges, the procurement must include the following specific components and upgrades:
A corrosive gas upgrade to prevent damage to internal components from corrosive chemical agents and chemical agent simulants.
A diffusion tube, diffusion tube membranes and gaskets, and a permeation tube kit.