USSPACECOM Headquarters (HQ) Command and Control Facility (C2F) Informational Industry Day

Closed Special Notice Posted

Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Huntsville, Alabama, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This Special Notice announces an Industry Day for the U.S. Space Command (USSPACECOM) Headquarters Command and Control Facility (C2F) project located on Redstone Arsenal in Huntsville, Alabama. Published by Army Contracting Command - Rock Island (ACC-RI) on behalf of the Air Force Civil Engineer Center (AFCEC) and USSPACECOM, this market research initiative seeks to engage qualified industry partners for a significant federal construction and management project. The facility will accommodate approximately 1,800 personnel across 700,000 square feet and will serve as a permanent warfighting headquarters supporting critical national security operations. The event represents the government's effort to identify capable firms before formal acquisition proceedings commence and is classified under NAICS Code 236220 (Commercial and Institutional Building Construction).

The Industry Day is scheduled for May 6, 2026, from 8:00 AM to 1:00 PM Central Time at the Alabama Space and Rocket Center in Huntsville, with virtual attendance via Zoom also available; the RSVP deadline is April 24, 2026 at 4:00 PM Central Time through the GoColosseum Marketplace portal. The government seeks qualified partners for two distinct roles: Owner's Representative Project Management and Design and Construction execution, with both acquisitions to be conducted using Other Transaction Authority (OTA) through the One Nation Innovation (ONI) Exchange GoColosseum Marketplace following Design-Build Institute of America (DBIA) best practices. Interested parties must demonstrate extensive expertise in technology-driven operations centers, resilient and redundant infrastructure, integrated IT systems, ICD 705 secure space standards, High-Altitude Electromagnetic Pulse (HEMP) hardening, and Radio Frequency (RF) shielding, with prime construction firms required to provide documentation of progressive design-build projects exceeding $500 million completed within the last five years. Registration requires submission of company information, CAGE Code, UEI, business classification, attendance preference, and primary area of interest through the GoColosseum Marketplace, with in-person attendance limited to three representatives per company.

Notice text

2 versions

Update #2 · Latest ·

Agency: Army Contracting Command - Rock Island (ACC-RI), on behalf of the Air Force Civil Engineer Center (AFCEC) and U.S. Space Command (USSPACECOM)

Location: Alabama Space and Rocket Center

U.S. Space & Rocket Center

One Tranquility Base

Huntsville, AL 35805

USSPACECOM requires a new, permanent warfighting HQ C2F on Redstone Arsenal to support its critical national security mission. A clean, 64-acre site on the installation has been designated for the USSPACECOM C2F. The operational HQ facility is expected to accommodate approximately 1800 personnel. Key facility components will include a Visitor Control Center, vehicle inspection area, and secure data center. The estimated total square footage (SF) for these primary facilities is 700,000 SF. The HQ facility will have stringent security features supporting 24/7 operations. Interested parties should be highly experienced in the design and construction of technology-driven operations centers, resilient and redundant infrastructure, integrated information technology (IT) systems, secure space (ICD 705) standards, High-Altitude Electromagnetic Pulse (HEMP) hardening, and Radio Frequency (RF) Shielding.


The Government intends to utilize a progressive design-build project delivery method following Design-Build Institute of America (DBIA) best practices. The acquisition for both the Owner's Representative and the design-build performance contractor will be executed using Other Transaction Authority (OTA) through the One Nation Innovation (ONI) Exchange GoColosseum Marketplace.

Update #1 ·

Agency: Army Contracting Command - Rock Island (ACC-RI), on behalf of the Air Force Civil Engineer Center (AFCEC) and U.S. Space Command (USSPACECOM)

Location: Specific location TBD. Huntsville, Alabama local commuting area.

USSPACECOM requires a new, permanent warfighting HQ C2F on Redstone Arsenal to support its critical national security mission. A clean, 64-acre site on the installation has been designated for the USSPACECOM C2F. The operational HQ facility is expected to accommodate approximately 1800 personnel. Key facility components will include a Visitor Control Center, vehicle inspection area, and secure data center. The estimated total square footage (SF) for these primary facilities is 700,000 SF. The HQ facility will have stringent security features supporting 24/7operations. Interested parties should be highly experienced in the design and construction of technology-driven operations centers, resilient and redundant infrastructure, integrated information technology (IT) systems, secure space (ICD 705) standards, High-Altitude Electromagnetic Pulse (HEMP) hardening, and Radio Frequency (RF) Shielding.


The Government intends to utilize a progressive design-build project delivery method following Design-Build Institute of America (DBIA) best practices. The acquisition for both the Owner's Representative and the design-build performance contractor will be executed using Other Transaction Authority (OTA) through the One Nation Innovation (ONI) Exchange GoColosseum Marketplace.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Industry Day: A Government-Industry Exchange on Construction Contracting - An Invitation for Industry Partners to Collaborate with the United States Space Force Operational Contracting Enterprise Colorado Springs, Colorado, United States · NAICS 23 Air Force Space Command No set-aside
Industry Day - Sentinel Utility Infrastructure Improvements at MAFB Malmstrom AFB, Montana, United States · NAICS 237130 ENDIST Seattle No set-aside
Global Aircrew Strategic Network Terminal Increment 2, Block 2 (GASNTi2b2) Industry Day - Initial Notice Hanscom AFB, Massachusetts 01731, United States · NAICS 541715 Nuclear Weapons Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity