About this opportunity
The Department of Homeland Security US Coast Guard seeks repairs and renovations to male and female staff locker rooms at Sector New York, Staten Island, with proposals due May 22. No set-aside applies.
Place of performance is 216 Coast Guard Drive, Staten Island, NY 10305. Work must be completed within 30 days of contract award, performed Monday through Friday from 0700 to 1530 hours. All contractor employees must obtain REAL ID clearance. SCA prevailing wage requirements apply; workers' compensation pay and benefits must comply with the most current prevailing wage rates for the period and place of performance.
The scope includes floor tile replacement (approximately 170 square feet of industrial linoleum tiles with 2.5mm minimum thickness and 50 linear feet of 4-inch rubber cove base in each locker room), vanity and sink fixture replacements (new industrial solid surface counters with 2 sinks each), toilet and urinal replacements (2 toilets and 2 urinals in the male locker room; 3 toilets in the female locker room), bathroom stall replacements with high-density polyethylene partitions, wall painting and patching (minimum two coats in contractor-selected colors approved by the Contracting Officer's Representative), locker replacement (8 existing lockers replaced with 10 new lockers in each locker room, approximately 72 inches height by 15 inches width by 24 inches depth), and bench installation (stainless steel legs, 17 inches height by 72 inches width by 10 inches depth in the male locker room; 17 inches height by 54 inches width by 10 inches depth in the female locker room). Licensed plumber requirements apply. All material submittals require Contracting Officer's Representative approval prior to ordering. The NAICS code is 236220, Commercial and Institutional Building Construction; PSC is Z2JZ, Repair Or Alteration Of Miscellaneous Buildings.
Notice text
This project consists of repairs and renovations to the male and female staff locker rooms to address interior and exterior deficiencies, improve functionality, and restore aesthetic quality. The work will include, but is not limited to floor tile replacement, vanity and sink fixture replacements, toilet and urinal replacements, bathroom stall replacements, wall painting and patching, and locker replacement
In accordance wityh the attached Statement Of Work (SOW).
SCA regulations appy.
workers compensations (pay and benefits) must be in accordance with the most current Previeling wage rate fo rthe period of preformance and place of preformance .
Files
| File | Type | Posted |
|---|---|---|
| PROJ SECNYHAB01 - Renew Galley Staff Locker Rooms.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| USCG sector new york – renew galley staff locker rooms SECNYHAB01 | Solicitation | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| MDC brooklyn - remove and replace shower partitions | Metropolitan Detention Center Brooklyn | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity