Trench Shield Equipment

Closed Solicitation Posted

Solicitation number
W911WN25QA012
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
333120 Construction Machinery Manufacturing
PSC
3895 Miscellaneous Construction Equipment
Place of performance
Saltsburg, Pennsylvania 15681, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Corps of Engineers Engineering District Pittsburgh is seeking a two-sided aluminum buildable panel trench shielding system for delivery to their Conemaugh River Lake location in Saltsburg, PA. The trench box system must include specific technical requirements, such as tongue and groove panels, corner posts, and an adjustable strut system with telescoping spreaders ranging from 36 to 48 inches. The equipment must be stackable up to eight feet in total height, weigh no more than 3,000 lbs, and include lifting lugs for movement. Vendors are required to submit an Operation and Maintenance Manual, Owner's Manual, and Spare Parts List with their proposal. The solicitation is open from March 26, 2025, with quotes due by April 7, 2025, and technical questions can be directed to Scott Bartholomew or William Andree during normal business hours.

This procurement is designated as a Total Small Business set-aside within the Construction Machinery Manufacturing (NAICS 333120) category. The contract requires delivery of the trench shielding system within 60 days of award, with the equipment to be delivered F.O.B. destination to 1665 Auen Road in Saltsburg, PA. The manufacturer must provide a one-year warranty covering materials and workmanship, and be responsible for any transportation-related damages. The system must include specific components such as panel box pins, keepers, 96" aluminum corner posts, and aluminum box panels measuring 2' x 10'. Quotes will only be accepted through the UNISON platform, and the equipment is intended for use by the US Army Corps of Engineers, with training from the manufacturer on proper use and construction of the trench shielding system being a mandatory requirement.

Notice text

QUOTES WILL ONLY BE ACCEPTED THROUGH UNISON

Specification for Buildable Trench shielding System

  1. GENERAL REQUIREMENTS.  These specifications establish the requirements to furnish a two-sided aluminum buildable panel trench shielding system. The shielding system, also known as a trench box, must be comprised of tongue and grove panels, corner posts, and an adjustable strut system. The system needs to be held together by pin and keeper system for easy set up and break down.

The buildable panel box system must have panels two foot in height by ten foot long and be stackable up to eight foot in total height. The panel box requires four eight-foot-long corner posts, four telescoping spreaders having an adjustable range between 36 inches to 48 inches. The buildable panel box system must be secured by easily removable pins and keepers rated for use in the requested application.  The trench box must have the ability to add panels to the open ends of the trench shoring system.

The total weight of the buildable panel box system must not exceed 3,000 lbs. and must be movable using securely installed lifting lugs at the corners of the system. Training from the manufacturer on the proper use and construction of the trench shielding system is required.

1.1 The trench shielding system will be delivered to US Army Corps of Engineers 1665 Auen Road Saltsburg, PA 15681-8127 with the following salient characteristics:

  1. Panel Box Pins – multiple required for box assembly
  2. Panel Box Keepers (used to keep pins in place)
  3. Telescoping spreaders - 36 inches to 48 inches
  4. Panel Box Lifting Lugs – Mounted on top of box corners
  5. 96” Aluminum Corner Posts
  6. Aluminum Box Panels (2’X10’)

2.0 SUBMITTALS.  The vendor is required to submit one (1) copy of the Operation and Maintenance Manual, Owner’s Manual, and Spare Parts List to the delivery location.

3.0 TECHNICAL QUESTIONS.  Technical questions may be directed to Scott Bartholomew at 724-301-4294 or William Andree at 724-541-8635 during normal business hours of operation.

4.0 WARRANTY.  The two-sided aluminum buildable panel trench shielding system shall have a manufacturer’s warranty for material and/or workmanship for a period of one year from date of delivery.     

5.0 DELIVERY.  The two-sided aluminum buildable panel trench shielding system shall be crated, boxed, or otherwise packaged to the extent necessary to prevent damage during shipment. All costs for repair and or replacement of damaged parts during transportation and delivery is the responsibility of the vendor.  

5.1 TIME OF DELIVERY.  The Government requires delivery of the two-sided aluminum buildable panel trench shielding system within 60 days after the date of a written notice of contract award.

5.2 PLACE OF DELIVERY.  The two-sided aluminum buildable panel trench shielding system supplied under this contract as specified in section 1.1 shall be delivered F.O.B. destination, transportation charges prepaid, to the following location:

   

William Andree – Conemaugh River Lake

1665 Auen Road

Saltsburg, PA 15681-8127

Telephone 724-541-8635

QUOTES WILL ONLY BE ACCEPTED THROUGH UNISON

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity