The inspection, testing, certification, and repair of aboveground and underground storage tanks
Closed Pre-Solicitation Posted
- Solicitation number
- PR00001
- Agency
-
Air Mobility Command
Air Force, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 561210 Facilities Support Services
- PSC
- J042 Maint/Repair/Rebuild Of Equip- Fire Fighting/Rescue/Safety Equip; Environ Protect Equip/Matls
- Place of performance
- Joint Base MDL, New Jersey 08641, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Mobility Command is seeking contractor services for the inspection, testing, certification, and repair of aboveground storage tanks (ASTs) and underground storage tanks (USTs) at Joint Base McGuire-Dix-Lakehurst. The contractor must provide comprehensive management and maintenance services, including serving as the central point of contact for compliance inspections, maintaining state certifications and licenses, and ensuring environmental regulatory compliance with federal, state, and local requirements. Key qualifications include maintaining New Jersey state certification for UST work, conducting inspections per 40 CFR Part 280 and industry standards (PEI RP900, PEI RP600, and STI SP001), and responding to emergency service calls within one business day of notification. The contractor must also register and maintain accounts in APIMS and STAR systems, obtain DoD Common Access Cards, and submit a quality control plan prior to contract start. The pre-solicitation notice was posted on March 6, 2026, with a question deadline of March 20, 2026, allowing potential offerors two weeks to submit inquiries before the formal solicitation is released.
This contract opportunity carries no set-aside designation and is open to all qualified contractors. The scope includes management of 12 underground storage tanks and 7 aboveground storage tanks located on the Dix/McGuire areas of the joint base. The contract establishes specific repair approval thresholds based on cost: the contractor absorbs labor costs for minor repairs under $100 per tank, repairs from $100 to $2,500 require Contracting Officer Representative approval, and repairs exceeding $2,500 require full Contract Officer approval. Repairs must commence within two days of approval and be completed within eight days, with completion reports submitted within 72 hours. While the pre-solicitation notice does not disclose the total contract value or award amount, the specific performance requirements and compliance obligations indicate a substantial scope of work covering environmental protection and equipment maintenance services.
Notice text
SEE THE ATTACHED PERFORMANCE WORK STATEMENT (pws)
Files
| File | Type | Posted |
|---|---|---|
| PWS (UST and AST) 13 JAN 26.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J045--RFQ - FY 27 - Petroleum Bulk Storage Tank Maintenance (B+4) | Veterans Integrated Service Network 2 | Total Small Business | |
| Fort Leavenworth Underground Fuel Tank Testing and Repair Services | MICC Fort Eustis | Total Small Business | |
| J091--Aboveground Fuel Tank Inspection Services - Kansas City VAMC | Veterans Integrated Service Network 15 | No set-aside |