The Dalles Unwatering Pump Pipe Rehab
Closed Solicitation Posted
- Solicitation number
- W9127N22R0010
- Agency
-
ENDIST Portland
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 332996 Fabricated Pipe and Pipe Fitting Manufacturing
- PSC
- 4710 Pipe, Tube And Rigid Tubing
- Place of performance
- The Dalles, Oregon 97058, United States
Notice details come from SAM.gov. Updated .
Notice text
Navigation Lock Unwatering Pumps Rebuild Requirements
Drawings:
Attachment 1: Navlock Unwatering Assembly Prelim drawing is for general pump overview and
if for information only.
Attachment 2: As-built drawing, DDN-20928-69-15, is only for reference. All dimensions are to
be pulled from the NL Unwatering Pump Assembly and NAVLOCK UNWATERING PUMP
ASSEMBLY - TYPICAL FLANGE drawing.
Attachment 3: NL Unwatering Pump Assembly hand sketch drawing provides assembly
dimensions and layout.
Attachment 4: NAVLOCK UNWATERING PUMP ASSEMBLY - TYPICAL FLANGE drawing provides
the layout and dimensions for to match bolt patterns for pump and discharge casing flange.
The Contractor shall field verify all measurements and layout prior to starting fabrication.
All provided quantities below are per pump. There are two pumps. Contractor to provide material for
two pump systems as described.
1. Pump shaft
a. Refer to Attachment 3 NL Unwater Pump Assembly Drawing for dimensions.
b. Refer to DDN-20928-69-15 for overall layout.
c. Material: 416 SS and pump shaft quality.
d. Three sections per pump @ 9’-11 ¾.
e. 2-7/16" x 9' 1-3/4" Headshaft: One section per pump @ 9’-1 ¾ . Contractor to provide
shaft adjusting nut that matches thread pitch for the Jump Coupling on the 2 7/16 side
of the shaft. Government will cut threads and keyway on motor adjustment end.
f. Thread length is to accommodate 2-3/16" Standard Shaft Couplings.
g. Acceptable runout: 2 Thou per foot
2. Casing
a. 18" x 9' 11-3/4" Flanged Columns Coated OD & ID
b. Refer to Attachment 4 NAVLOCK UNWATERING PUMP ASSEMBLY - TYPICAL FLANGE
drawing for layout and dimensions for to match bolt patterns for pump and discharge
casing flange.
c. 3 sections per pump @ 9’-11 ¾,
d. Material: Steel meeting pump industry standards.
e. Coating is the be epoxy to prevent erosion and corrosion. Coating to be applied inside
and outside.
3. Shaft couplers
a. Refer to Attachment 3 NL Unwater Pump Assembly Drawing for sketch of location on
assembly.
b. Three 2-3/16" Standard Shaft Couplings
c. One 2-3/16" x 2-7/16" Jump Coupling (aka Reducer
Coupler)
d. Match shaft threads
4. Bearing Retainer (aka Spiders) with rubber bearing insert, Open Line Shaft
a. Sandwiched between casing sections as shown in example Figure 1.
b. Complete bearing assembly including rubber bearing and keepers.
c. Material: Bearing Retainer is to be Bronze; the rubber bearing is to have properties like
Nitrile Butadiene Rubber (NBR)
Figure 1 Desired Retainer Bearing Configuration