Submit a quote to: 1. Provide, install, and maintain 20MB mpls layer 2 ethernet circuit between bldg 308 RM 203, FLR: 0, 5450 carlisle pike, mechanicsburg, PA 17050 and bldg 490 RM: demarc room, FLR: 0, 490 sussex drive ottawa, ontrio canada.

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
HC101324QA147
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Defense Information Systems Agency (DISA) is soliciting quotes to provide, install, and maintain a 20Mb MPLS Layer 2 Ethernet circuit between a location in Mechanicsburg, PA and a location in Ottawa, Ontario, Canada. The key requirements include establishing a Telecommunications Service Priority (TSP), maintaining 99.5% or better service availability with 30-minute response and 2-hour restoration times, and adhering to specific repair and reporting requirements. Quotes must comply with all standard provisions, clauses, and address specific sections to be deemed technically acceptable. No terms, conditions, or assumptions will be entertained, and the government personnel will make the final determination of technical acceptability.

This opportunity is not set aside for any specific business type. The NAICS code is likely 517311 (Wired Telecommunications Carriers) and the PSC code is D304 (ADP Telecommunications Services). The current contractor is Level 3 Communications, LLC under a separate contract. The estimated contract value is not specified, and the period of performance is not explicitly stated. The two locations identified serve as the place of performance.

Notice text

SUBMIT A QUOTE TO: 1. PROVIDE, INSTALL, AND MAINTAIN 20MB MPLS LAYER 2 ETHERNET CIRCUIT BETWEEN BLDG 308 RM 203, FLR: 0, 5450 CARLISLE PIKE, MECHANICSBURG, PA 17050 (CCI ) AND BLDG 490 RM: DEMARC ROOM, FLR: 0, 490 SUSSEX DRIVE OTTAWA, ONTRIO CANADA (CCI). 2. ESTABLISH TSP FOR THIS SERVICE. 3. CIRCUIT ID: TBD ***REMARKS*** 1. CONTRACTOR MUST CONTACT THE SITE POC(S) AT LEAST 72 HRS PRIOR TO INSTALLATION. 2. CONTRACTOR MUST CALL AT LEAST 72 HRS PRIOR TO MAINTENANCE. 3. CUSTOMER WILL ACCEPT EARLIEST POSSIBLE INSTALL DATE. (SIP) 4. THIS IS A CANDIDATE FOR RESTORAL TELECOMMUNICATIONS SERVICE PRIORITY (TSP). 5. SERVICE AVAILABILITY 99.5% OR BETTER, WITH 30 MINUTE RESPONSE; 2 HOUR RESTORAL; UPDATES PROVIDED EVERY 60 MINUTES UNTIL CIRCUIT IS FULLY TESTED AND OPERATIONAL. VENDOR MUST HAVE 24 HOUR MONITORING FACILITIES AND EQUIPMENT TO TROUBLESHOOT PATH AND ASSOCIATED EQUIPMENT AFTER INSTALLATION. 6. COMPLETE OUTAGE: INTERFACE OR PROTOCOL NON-OPERATIONAL RESPONSE TIME FROM INITIAL REPORT OR DETECTION OF CIRCUIT DOWN WILL BE 30 MINUTES AND THE MEAN RESTORE TIME TO REPAIR (MTTR) MUST BE 120 MINUTES. 7. IMPAIRMENT: IMPAIRED THROUGHPUT OR IMPAIRED CIRCUIT OPERTION (EG. LATENCY ISSUES, INTERMITTENTLY FLAPPING/BOUNCING, INTERMITTENT ISSUES) RESPONSE TIME FROM INITIAL REPORT OR DETECTION OF CIRCUIT IMPAIRMENT WILL BE 30 MINUTES AND THE MEAN RESTORE TIME TO REPAIR (MTTR) MUST BE 240 MINUTES. 8. CIRCUIT MUST AVOID SATELLITE LINKS. 9. CONTRACTOR MUST CONTACT THE BELOW LISTED POC AT LEAST 2 WEEKS PRIOR TO INSTALLATION, ACCESS WILL NOT BE GRANTED WITHOUT THE 2 WEEK PRIOR APPROVAL, TECHS WILL BE TURNED AWAY WITHOUT THE APPROVAL 10. JURISDICTIONAL CLASS: INTERSTATE USE, 100 PERCENT 11. CURRENT CONTRACTOR IS LEVEL 3 COMMUNICATIONS, LLC. UNDER CSA LEVC000161EBM AS A 10MPS MPLS LAYER 2 CIRCUIT. ***NOTE: THE CONTRACTOR MUST PROVIDE TSR, CCSD OR CSA IN ALL CORRESPONDENCE INCLUDING WHEN DELIVERING CIRCUIT TO SITE POC*** TECHNICAL ACCEPTABILITY EVALUATION CRITERIA: A QUOTE MUST COMPLY WITH ALL STANDARD PROVISIONS, PROVISIONS, CLAUSES, AND ADDRESS SECTIONS F-M OF THE SOLICITATION TO BE DEEMED TECHNICALLY ACCEPTABLE. ALL PORTIONS OF THE SOLICITATION SHOULD BE CAREFULLY REVIEWED FOR ALL MANDATED REQUIREMENTS OUTLINED WITHIN THE STANDARD PROVISIONS AND DOCUMENTATION REQUESTED AS FOUND IN SECTION M AND AFFILIATED ATTACHMENTS. QUOTATIONS MUST INCLUDE ALL REQUIRED DOCUMENTS AND RESPONSES INDICATED FROM THESE STANDARD PROVISIONS, PROVISIONS, CLAUSES, SECTION M, AND AFFILIATED ATTACHMENTS TO BE CONSIDERED TECHNICALLY ACCEPTABLE AND/OR ELIGIBLE FOR AWARD. IN RESPONSE TO THIS IQO SOLICITATION, NO TERMS, CONDITIONS, OR ASSUMPTIONS WILL BE ENTERTAINED. IF TERMS, CONDITIONS, AND/OR ASSUMPTIONS ARE INCLUDED IN A QUOTATION, THE QUOTATION MAY BE EXCLUDED ON GROUNDS THAT IT FAILED TO COMPLY WITH THE IQO SOLICITATION INSTRUCTIONS. EVALUATION CRITERIA: IN ADDITION TO THE PROCEDURES OUTLINED IN STANDARD PROVISION 23, TECHNICAL EVALUATION TEAM MEMBERS WILL INCLUDE GOVERNMENT PERSONNEL AND MAY INCLUDE GOVERNMENT'S CONTRACTED ADVISORS. GOVERNMENT PERSONNEL WILL MAKE THE FINAL DETERMINATION OF TECHNICAL ACCEPTABILITY. IF THERE ARE QUESTIONS REGARDING SITE SURVEYS OR SITE INFORMATION PLEASE CONTACT THE CONTRACT SPECIALIST LISTED ON THIS SOLICITATION PRIOR TO THE QUOTE DUE DATE.

Files

File Type Posted
HC101324QA147_v2.zip ZIP file

Notice history

Notice Type Posted
Award notice Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors