The Department of the Army Medical Command seeks to procure a PR-745 SpectraScan spectroradiometer system manufactured by Photo Research Inc. and distributed by Novanta Corporation. The system must provide spectral measurements from 380 to 1080 nm and include specific instrumentation and accessories. Proposals are due by July 13, 2022. The agency will evaluate offers based on the offeror's ability to provide the required instrumentation and support to expand the organization's visual sciences research capabilities.

The opportunity is partially set aside for small businesses. The predominate NAICS code is 334510 and PSC code is 6625. The incumbent contractor is Photo Research Inc. The value of the contract is estimated at $250,000 for one unit of the spectroradiometer system and two years of support services. The agency requires delivery and installation within 90 days of award.

Notice text

USAARL requires the capabilities of the PR-745 SpectraScan®, Sprectroradiometer and instrumentation and support accessories, manufactured by Photo Research Inc., and distributed by Novanta Corporation. This Spectroradiometer provides spectral measurements from 380 to 1080 nm (ideal for near IR testing). The instrument, exhibits virtually no polarization error or stray light, the instrument can be equipped with up to 8 measuring apertures, the instrument can be equipped with twice as many detectors as other instruments in their class, the instrument can communicate and provides a full-color touch screen display and SD card measurement storage for menu navigation and measured data presentations.  This system will include the following instrumentation and support accessories:

1). PR-745,Spectrascan, North America; P/N: 6745-0001-00, 2). Pro Geared Tripod; P/N: 6000-0019-01, 3). PR-730 SDK (WINDOWS .DLL); P/N: 6730-0002-03, 4). USC-730,User Self Calibration Software; P/N: 6730-0002-04, 5). SW-730,Upgrade SW-2 Lite to Pro; P/N: 6730-0002-07, 6). Aperture,2° Round; P/N: 6730-0004-00, 7). Aperture,1° Round; P/N: 6730-0004-01, 8). Aperture, 0.1° Round; P/N: 6730-0004-06, 9). LA-730,Luminance Adapter; P/N: 6730-0008-09, 10). LR-730, LED Receptor, PR-730; P/N: 6730-0008-13, 11). SL-1X, Supplementary Lens; P/N: 6730-0008-17, 12). FP-730, 10 Ft. Flexible Fiber Probe; P/N: 6730-0008-28, 13). CR-730, Cosine Receptor – Straight; P/N: 6730-0008-34, 14). BP-730 LI-ION Rechargeable BAT.; P/N: 6730-0009-02, 15). USB-10, 10 Ft., USB Cable; P/N: 6730-0009-10, and 16). CC-730, Wheeled Molded Hard Carrying Case With Telescoping Handle; P/N: 6730-0009-15, 17). 2-Year Service Contract, PR-745; P/N: 6730-0011-00, 18). VBW-PR-745 4, 8, and 14; P/N: 6745-0003-00, and 19). Virtual Reality Measurement Adapter - 4mm pupil; P/N: 6740-0008-02. The addition of this system will expand USAARL’s visual sciences research capabilities and support the organizations research protocols.

USAARL requires the capabilities of the PR-745 SpectraScan®, Sprectroradiometer and instrumentation and support accessories, manufactured by Photo Research Inc., and distributed by Novanta Corporation. This Spectroradiometer provides spectral measurements from 380 to 1080 nm (ideal for near IR testing). The instrument, exhibits virtually no polarization error or stray light, the instrument can be equipped with up to 8 measuring apertures, the instrument can be equipped with twice as many detectors as other instruments in their class, the instrument can communicate and provides a full-color touch screen display and SD card measurement storage for menu navigation and measured data presentations.  This system will include the following instrumentation and support accessories:

1). PR-745,Spectrascan, North America; P/N: 6745-0001-00, 2). Pro Geared Tripod; P/N: 6000-0019-01, 3). PR-730 SDK (WINDOWS .DLL); P/N: 6730-0002-03, 4). USC-730,User Self Calibration Software; P/N: 6730-0002-04, 5). SW-730,Upgrade SW-2 Lite to Pro; P/N: 6730-0002-07, 6). Aperture,2° Round; P/N: 6730-0004-00, 7). Aperture,1° Round; P/N: 6730-0004-01, 8). Aperture, 0.1° Round; P/N: 6730-0004-06, 9). LA-730,Luminance Adapter; P/N: 6730-0008-09, 10). LR-730, LED Receptor, PR-730; P/N: 6730-0008-13, 11). SL-1X, Supplementary Lens; P/N: 6730-0008-17, 12). FP-730, 10 Ft. Flexible Fiber Probe; P/N: 6730-0008-28, 13). CR-730, Cosine Receptor – Straight; P/N: 6730-0008-34, 14). BP-730 LI-ION Rechargeable BAT.; P/N: 6730-0009-02, 15). USB-10, 10 Ft., USB Cable; P/N: 6730-0009-10, and 16). CC-730, Wheeled Molded Hard Carrying Case With Telescoping Handle; P/N: 6730-0009-15, 17). 2-Year Service Contract, PR-745; P/N: 6730-0011-00, 18). VBW-PR-745 4, 8, and 14; P/N: 6745-0003-00, and 19). Virtual Reality Measurement Adapter - 4mm pupil; P/N: 6740-0008-02. The addition of this system will expand USAARL’s visual sciences research capabilities and support the organizations research protocols.

Files

File Type Posted
Market research specialist.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Scintillometer BLS900 Neo, Path Reduction Aperture, Power Supply, Standard and Tall Tripods White Sands Missile Range, N.M. 88002 88002 · NAICS 334519 MICC Fort Drum Total Small Business
Handheld Spectrometer Corpus Christi, Texas 78419, United States · NAICS 334516 ACC Redstone No set-aside
Sources Sought for (ICP-OES) Spectrometer System with an Autosampler Annapolis, Maryland 21402, United States · NAICS 334516 Naval Supply Systems Command No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors