Sewage Ejector and Line Assessment

Cancelled Solicitation Posted

Solicitation number
W912BV26QA069
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army Corps of Engineers Engineering District Tulsa seeks assessment, inspection, and modification of an unmapped 700 to 800 foot concrete-encased four inch cast iron sewer line and associated distribution box, with proposals due October 28. The solicitation reopened from August 18 to September 11, with a mandatory site visit on September 3 at Robert S. Kerr Powerhouse, 29759 Powerhouse Road, Keota, Oklahoma at 10 a.m.

Place of performance is Keota, Oklahoma. The contractor must locate and inspect the existing line, install concrete-encased Schedule 40 PVC double-Y clean-outs every 300 feet, expose and inspect the distribution box and its 2009 leach field connections, and extend the box cover using a riser and structural cover rated for three ton vehicle traffic protected by four concrete-encased steel safety-yellow bollards. Government presence is mandatory during all site inspections. All physical, material, and dimensional adjustments must be documented as Red Line As-Builts on the reference drawing. The contractor must deliver a detailed findings report that includes recommended corrective actions for the lateral lines along with comprehensive labor and material cost estimates. The NAICS code is 237110, Water and Sewer Line and Related Structures Construction; PSC code is J045, Maint/Repair/Rebuild of Equipment—Plumbing, Heating, and Waste Disposal Equipment.

Notice text

4 versions

Update #4 · Latest ·

This scope of work requires the contractor to locate, inspect, and modify an unmapped 700 to 800 foot concrete-encased four inch cast iron sewer line and its associated distribution box, with mandatory Government presence during all site inspections. Key tasks include installing concrete-encased Schedule 40 PVC double-Y clean-outs every 300 feet, exposing and inspecting the distribution box and its 2009 leach field connections, and extending the box cover using a riser and structural cover rated for three ton vehicle traffic protected by four concrete-encased steel safety-yellow bollards. All physical, material, and dimensional adjustments must be documented as Red Line As-Builts on the reference drawing, and any recommended corrective actions for the lateral lines must be delivered via a detailed findings report with comprehensive labor and material cost estimates.

Update #3 ·

Changes site visit date to 3 September 2026. (Robert S. Kerr Powerhouse 29759 Powerhouse Road Keota, Oklahoma, 74941 @10am

Update #2 ·

Sewage Ejector and Line Assessment:Reopens Solicitation from 18 August 2026 to 11 September 2026.Adds site visit information 27 August 2026.

Update #1 ·

Sewage Ejector and Line Assessment

Similar open opportunities

Opportunity Agency Set-aside Responses due
Arcadia Wet Well Rehabilitation NAICS 237990 ENDIST Tulsa No set-aside
Fall River Lake and Dam Damsite Park Lagoon Repair U.S. Army Corps of Engineers Fall River Lake Project Office2453 Lake RdFall River, KS 67047 67407 · NAICS 237990 ENDIST Tulsa Total Small Business
Kelly Pierson OSS Shelton, Washington, United States · NAICS 237110 Indian Health Service Total Small Business
DCDO Septic Tank and Sewage Treatment Maintenance 96367 Japan · NAICS 221320 Pacific Air Forces No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity