SEQUOIA Dual Point Davit Repair
Closed Special Notice Posted
- Solicitation number
- 70Z085Q250019226
- Agency
-
Coast Guard
Department of Homeland Security
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 336611 Ship Building and Repairing
- Place of performance
- Port Huron, Michigan 48060, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Coast Guard (USCG) has issued a Special Notice for a sole-source Statement of Work (SOW) to repair the Welin Lambie Davit Twin PIV 5.0B System on the USCGC Sequoia following a small Charlie Fire in a control panel. The incident caused damage to several terminals, wires, and components, necessitating certified technical representatives from Wellin Lambie to conduct onsite troubleshooting, repairs, and function tests. The contract opportunity is published by the Department of Homeland Security's U.S. Coast Guard and is categorized under Ship Building and Repairing (NAICS 336611) and Marine Equipment Maintenance (PSC J020). The solicitation is classified as a Special Notice without a specific set-aside and was posted on May 27, 2025, with a response deadline of June 6, 2025.
The primary objective of this Special Notice is to secure a qualified contractor to provide a senior service field technician to perform comprehensive inspection, repair, and testing of the damaged davit system. The contract requires the technician to work 8 hours per day for 5 weekdays from June 9-13, 2025, with the specific repair facility yet to be determined. Contractors must provide qualified personnel who can professionally comply with all government regulations, avoid conflicts of interest, and possess a valid Real I.D. for facility access. The SOW includes a detailed list of required replacement parts, such as DIN rail components, relays, terminal blocks, and protection modules. Contractor personnel must maintain professional conduct, adhere to government policies, and ensure their work does not reflect discredit upon the U.S. Government. The primary point of contact for this opportunity is CWO Albert (Lee) Lowery, Engineer Officer at USCGC Sequoia in Port Huron, Michigan.
Notice text
THIS IS TO BE AWARDED SOLE SOURCE
STATEMENT OF WORK (SOW)
- BACKGROUND
CGC SEQUOIA suffered a small Charlie Fire within a control panel for the Wellin Lambie Davit System. Several terminals, wires, and other components were damaged, and the DISCREP requires certified technical representatives from Wellin Lambie to conduct onsite troubleshooting, repairs, and function tests. At the request of the vendor, pictures can be sent for preliminary part requirement inquiry. Ship’s force were able to identify where the fire could have originated.
- REFERENCE
N/A
- REQUIREMENTS
-
-
-
- TO PROVIDE (1) SENIOR SERVICE FIELD TECHNICIAN WORKING (8) HRS PER DAY FOR (5) WEEKDAYS ON BOARD USCGC SEQUOIA TO ACCOMPLISH WELIN LAMBIE DAVIT TWIN PIV 5.0B SYSTEM INSPECTION, REPAIR, AND TEST.
- PARTS:
- 1000-8 DIN RAIL COMPLETE ASSEMBLED -1
- 859-02697 HYGROSTAT -1
- 859-03030 RELAY -7
- 859-03031 RELAY BASE -7
- 859-03032 RELAY RETAINING CLIP -7
- 859-02640 TOP HAT DIN RAIL -1
- 859-02400 MODULAR TERMINAL -33
- 859-02401 MODULAR TERMINAL -18
- 859-02405 END CLAMP -5
- 859-02410 PARTITION -12
- 859-02437 JUMPER BAR INSULATED -5
- 859-02439 JUMPER BAR INSULATED -1
- 859-02443 JUMPER BAR INSULATED -1
- 859-02685 ANGLE BRACKETS -4
- 859-03135 PROTECTION MODULE -7
- 9999 FERRULES & NUMBERING -1
- 1000-8 DIN RAIL COMPLETE ASSEMBLED -1
-
-
- 4.0 ADMINISTRATION.
4.1 CONTRACTOR PERSONELL
4.1.1 Qualified Personnel.
The Contractor shall provide qualified personnel and subject matter experts to perform all required tasks specified in this SOW.
4.1.2 Employee Conduct.
Contractor employees shall present a professional appearance, and their conduct shall not reflect discredit upon the U.S. Government, and any involved Departments or Agencies. Contractor employees shall comply with all applicable Government regulations, policies, and procedures (e.g., fire, safety, sanitation, environmental protection, security, “off limits” areas, wearing of parts of military uniforms, and possession of weapons) when visiting or working at Government facilities.
4.1.3 Conflict of Interest.
The Contractor shall not employ any person who is an employee of the U.S. Government if that employment would, or would appear to cause, a conflict of interest. The Contractor shall take appropriate precautions as delineated in the Federal Acquisition Regulation (FAR) to preclude actual or apparent conflicts of interest.
4.1.4 Facility Access
The contractor must provide a valid Real I.D.
4.2 PERIOD OF PERFORMANCE.
09JUN2025-13JUN2025
4.3 PLACE OF PERFORMANCE.
Repair facility to be determined.
5.0 USCG POC’S
CGC SEQUOIA
2700 Omar Street
Port Huron, MI 48060
POC CWO Albert (Lee) Lowery, Engineer Officer
(907) 487-5344
Email: Albert.L.Lowery@uscg.mil
Product Line Support:
ENS Marcos Saldarriaga
667-419-5729
Marcos.A.Saldarriaga@uscg.mil
Files
| File | Type | Posted |
|---|---|---|
| Smart Matrix Acquisition.GOV-SERVICE.pdf | ||
| SAM.gov SERVICE WAGE ST CLAIR COUNTY MI.pdf | ||
| Scope of Work - Sequoia.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Dock-side (DS): USCGC WAESCHE Quarter 2 FY27 Repair | — | No set-aside | |
| Drydock: USCGC cobia dry dock availability FY2026 | Coast Guard | No set-aside | |
| USCGC maria bray (WLM 562) dockside repair FY27 | — | No set-aside | |
| CGC sangamon drydock repairs | — | No set-aside | |
| Drydock Repairs USCGC HATCHET (WLIC-75309) | — | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity