Safety Air Monitoring Replacement Gas Chromatograph (GC)
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W911S6-23-Q-0033
- Agency
-
MICC Fort Hood
Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6630 Chemical Analysis Instruments
- Place of performance
- Dugway, Utah 84022, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Materiel Command Mission and Installation Contracting Command Fort Hood is seeking to procure two Gas Chromatograph (GC) instruments for air monitoring at the Dugway Proving Ground in Utah. The key requirements include a Flame Photometric Detector with phosphorous and sulfur optical filters, specific chromatographic columns, air sampling pre-concentrator trap capability, electronic pressure control, and compact size and weight. The solicitation has a response due date of April 30, 2024 and requires delivery within 30 days of contract award.
This is a sole source procurement set aside for Teledyne Instruments Incorporated under NAICS code 334516 with a size standard of 1,000 employees. The estimated value is between the simplified acquisition threshold and $750,000. The existing MINICAMS instruments used for this purpose are being discontinued, necessitating the replacement with the Teledyne Falcon GC, which is the only commercially available instrument that meets the government's specific requirements based on market research.
Notice text
A Gas Chromatograph (GC) instrument is needed for air monitoring in replacement of MINICAMS instruments.
Procure two GC instruments with the following specifications:
-
- Flame Photometric Detector (DFPD); one instrument with phosphorous optical filter, one instrument with sulfur optical filter
- Chromatographic columns: one instrument DB-1 phase and one instrument DB-210 phase column; one DB-1701 column that can be installed at a later date by the user
- Air sampling pre-concentrator trap capability with flow rate through the trap of at least 500mL/min
- Capability to add mass flow controller and collect flow date
- Cycle time from injection to injection of 15 minutes or less
- Electronic pressure control (EPC) of gases
- Displayed control zones, valve status, temperature, pressure, and voltage.
- Built in data acquisition system
- GC dimensions - 17” x 11” x 8.5” (width x height x depth)
- Instrument weight approximately 25 pounds
- Alarm capability based on analyte response
Shipping: Shall be shipped within 30 days of contract award.
Files
| File | Type | Posted |
|---|---|---|
| JA Samars FAR 13.5.pdf | ||
| SAMARS Combined Synopsis Solicitation SoleSource.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Safety Air Monitoring Replacement Gas Chromatograph (GC) | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Single Purchase of an Agilent 8890 GC System Custom with dual ECD detectors | EPA Region 4 | No set-aside | |
| ICP-OES for Oil Analysis | MICC Fort Drum | Total Small Business | |
| Upgrade to the FTIR Microscope, Raman Microscope and Ion Chromatograph equipment | Naval Sea Systems Command | No set-aside | |
| Detector, Gas | Land and Maritime | Total Small Business | |
| Measuring tube, gas an and 1 more item | Medical Supply Chain | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity