Safety Air Monitoring Replacement Gas Chromatograph (GC)

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W911S6-23-Q-0033
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Dugway, Utah 84022, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Materiel Command Mission and Installation Contracting Command Fort Hood is seeking to procure two Gas Chromatograph (GC) instruments for air monitoring at the Dugway Proving Ground in Utah. The key requirements include a Flame Photometric Detector with phosphorous and sulfur optical filters, specific chromatographic columns, air sampling pre-concentrator trap capability, electronic pressure control, and compact size and weight. The solicitation has a response due date of April 30, 2024 and requires delivery within 30 days of contract award.

This is a sole source procurement set aside for Teledyne Instruments Incorporated under NAICS code 334516 with a size standard of 1,000 employees. The estimated value is between the simplified acquisition threshold and $750,000. The existing MINICAMS instruments used for this purpose are being discontinued, necessitating the replacement with the Teledyne Falcon GC, which is the only commercially available instrument that meets the government's specific requirements based on market research.

Notice text

A Gas Chromatograph (GC) instrument is needed for air monitoring in replacement of MINICAMS instruments.  

Procure two GC instruments with the following specifications:

    • Flame Photometric Detector (DFPD); one instrument with phosphorous optical filter, one instrument with sulfur optical filter
    • Chromatographic columns: one instrument DB-1 phase and one instrument DB-210 phase column; one DB-1701 column that can be installed at a later date by the user
    • Air sampling pre-concentrator trap capability with flow rate through the trap of at least 500mL/min
    • Capability to add mass flow controller and collect flow date
    • Cycle time from injection to injection of 15 minutes or less
    • Electronic pressure control (EPC) of gases
    • Displayed control zones, valve status, temperature, pressure, and voltage.
    • Built in data acquisition system
    • GC dimensions - 17” x 11” x 8.5” (width x height x depth)
    • Instrument weight approximately 25 pounds
    • Alarm capability based on analyte response

Shipping: Shall be shipped within 30 days of contract award.

Files

File Type Posted
JA Samars FAR 13.5.pdf PDF
SAMARS Combined Synopsis Solicitation SoleSource.pdf PDF

Notice history

Notice Type Posted
Safety Air Monitoring Replacement Gas Chromatograph (GC) Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Single Purchase of an Agilent 8890 GC System Custom with dual ECD detectors NAICS 221310 EPA Region 4 No set-aside
ICP-OES for Oil Analysis Yuma Proving Ground301 C Street Bldg 2410Yuma, Az 85365 85365 · NAICS 334516 MICC Fort Drum Total Small Business
Upgrade to the FTIR Microscope, Raman Microscope and Ion Chromatograph equipment Indian Head, Maryland 20640, United States · NAICS 334516 Naval Sea Systems Command No set-aside
Detector, Gas NAICS 334511 Land and Maritime Total Small Business
Measuring tube, gas an and 1 more item Medical Supply Chain No set-aside