Rydberg Rb with Difference Frequency Comb Lock Laser System

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
N00173-20-Q-CY01
Agency
Office of Naval Research Secretary of the Navy, Department of Defense
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
334516 Analytical Laboratory Instrument Manufacturing
PSC
H158 Quality Control- Communication, Detection, And Coherent Radiation Equipment
Place of performance
Washington DC 20375 USA

Notice details come from SAM.gov. Updated .

About this opportunity

The Naval Research Laboratory seeks to procure a complete, turn-key laser system to support quantum memory experiments using Rydberg states. The system must include a continuous wave frequency doubled laser at 480nm with 800mW output power and linewidth less than 100kHz, as well as an intrinsically stable difference frequency comb with 4 CEO-free outputs at 1560nm and bandwidth over 20nm. Control electronics and central control software are required to integrate and remotely operate all system components. Proposals will be evaluated for technical acceptability and the award will be made to the offer representing the lowest price technically acceptable solution, with submissions due by April 24, 2020.

No set-aside designation was used for this procurement. The solicitation is anticipated to result in a firm fixed price contract to acquire one laser system with key components including a frequency doubled laser, difference frequency comb, and control electronics. The place of performance will be the Naval Research Laboratory in Washington, D.C. and the system must be delivered, installed, and training provided by August 31, 2020.

Notice text

2 versions

Update #2 · Latest ·

REVISED SPECS UNDERLINED IN BOLD

I. Description of Requirement

NRL Quantum Electro-Optics Section 5613 requires a complete, turn-key, stabilized laser system to transition recent quantum memory experiments towards a more scalable and versatile configuration with the use of Rydberg states. A turn-key system meaning laser, comb and all accessories are controlled from a central system or computer GUI where the laser parameters and locks can be implemented and diagnosed. The system has to be capable of 24h/7d operation within laboratory environment. The user interface has to feature an automatic lock of the comb to RF reference, remote locking of 480 nm laser and extension CW laser.


The system will be assembled and characterized at the factory to verify specifications of the complete system. It will be shipped and reassembled to working order at NRL site and include on-site training. The complete unit will provide controls for all locks, system parameters and diagnostics from a computer GUI and the parameters must be accessible with external commands so that the system can be utilized in an experimental sequence suitable to operate a quantum memory. 

II. Performance Requirements

Laser specification (CW frequency doubled laser at 480nm), QNTY: 1

CW frequency doubled (SHG) laser with 800 mW output power at the wavelengths of 473-481 nm

• Output power at least 800 mW

• Coarse tuning of 8 nm over 473—481 nm, with mode hop-free tuning greater than 15 GHz

• Linewidth less than 100 kHz

• Output power stabilization

• Probe beam output at fundamental wavelength

• High quality digital Pound-Drever-Hall stabilization of SHG resonator length with automatic relocking

• Ability for fast frequency modulation of master laser (with protective circuit for laser diode)

Frequency Comb Specification (Difference Frequency Comb), QNTY: 1 (with extension modules)

Intrinsically stable frequency comb with passive, all-optical phase-lock, which inherently stabilizes fCEO and the carrier envelope phase.

• 4 fCEO-free (offset-free) outputs at 1560 nm with power greater than 10 mW at each output

• Bandwidth greater than 20 nm at each output

• Stability (locked to RF reference): short-term at least 1x10-13 in 1 s

• Stability (locked to Optical reference): short-term at least 8x10-18 in 1 s, long-term 5×10-20 in 1000 s

• Wavelength extensions for non-linear conversion:

o Supercontinuum output centered at 1475 nm with at least 200 nm bandwidth

o NIR output at 780 nm with bandwidth >35 nm and output power at least 50 mW (to include 795 nm)

o Output centered at (or to include) 960 nm with bandwidth at least 40 nm

• Live frequency measurement of CW laser

• Wavelength meter with measurement range 330 to 1180 nm and absolute accuracy sufficient for unambiguous determination of comb line order number. The wavelength meter must be capable of CW and pulsed laser measurement and must be fiber coupled. It must have an input for calibration laser and a stabilized HeNe-Laser must be included for calibration of the wavelength meter. Wavelength meter must have a computer interface and must be fully integrated into comb control software

Control Electronics

Control and locking electronics for the laser and frequency comb with beat-note detectors, counter and oscilloscope with spectrum analyzer

Integrated specification

Central control unit from a computerized central system or control GUI must:

• allow control of the optical frequency comb operation and provide diagnostics and status

• allow the full control of the laser, incl. locks, parameters and status

• allow control of the wavelength meter

• be capable of providing live frequency measurements of cw lasers

• provide automatic calculation and plotting of Allan deviation from logged data

The laser system must be capable of working with lasers currently in possession of Code 5613, namely Toptica DL Pro and Toptica TA Pro lasers. This means that the frequency comb part of the system will be able to lock those lasers, operating at 780 nm, 795 nm and 1474 nm, and set the absolute frequency of those lasers.

See complete RFQ attached for additional details. Revised specs are highlighted.

Update #1 ·

I. Description of Requirement

NRL Quantum Electro-Optics Section 5613 requires a complete, turn-key, stabilized laser system to transition recent quantum memory experiments towards a more scalable and versatile configuration with the use of Rydberg states. A turn-key system meaning laser, comb and all accessories are controlled from a central system or computer GUI where the laser parameters and locks can be implemented and diagnosed. The system has to be capable of 24h/7d operation within laboratory environment. The user interface has to feature an automatic lock of the comb to RF reference, remote locking of 480 nm laser and extension CW laser.


The system will be assembled and characterized at the factory to verify specifications of the complete system. It will be shipped and reassembled to working order at NRL site and include on-site training. The complete unit will provide controls for all locks, system parameters and diagnostics from a computer GUI and the parameters must be accessible with external commands so that the system can be utilized in an experimental sequence suitable to operate a quantum memory. 

II. Performance Requirements

Laser specification (CW frequency doubled laser at 480nm), QNTY: 1

CW frequency doubled (SHG) laser with 800 mW output power at the wavelengths of 473-481 nm

• Output power at least 800 mW

• Coarse tuning of 8 nm over 473—481 nm, with mode hop-free tuning greater than 15 GHz

• Linewidth less than 100 kHz

• Output power stabilization

• Probe beam output at fundamental wavelength

• High quality digital Pound-Drever-Hall stabilization of SHG resonator length with automatic relocking

• Ability for fast frequency modulation of master laser (with protective circuit for laser diode)

Frequency Comb Specification (Difference Frequency Comb), QNTY: 1 (with extension modules)

Intrinsically stable frequency comb with passive, all-optical phase-lock, which inherently stabilizes fCEO and the carrier envelope phase.

• 4 fCEO-free (offset-free) outputs at 1560 nm with power greater than 10 mW at each output

• Bandwidth greater than 20 nm at each output

• Stability (locked to RF reference): short-term at least 10-16 in 1 s, long-term 3×10-18 in 1000 s

• Wavelength extensions for non-linear conversion:

o Supercontinuum output centered at 1475 nm with at least 200 nm bandwidth

o NIR output at 780 nm with bandwidth >35 nm and output power at least 50 mW (to include 795 nm)

o Output centered at (or to include) 960 nm with bandwidth at least 40 nm

• Live frequency measurement of CW laser

• Wavelength meter with measurement range 330 to 1180 nm and absolute accuracy sufficient for unambiguous determination of comb line order number. The wavelength meter must be capable of CW and pulsed laser measurement and must be fiber coupled. It must have an input for calibration laser and a stabilized HeNe-Laser must be included for calibration of the wavelength meter. Wavelength meter must have a computer interface and must be fully integrated into comb control software

Control Electronics

Control and locking electronics for the laser and frequency comb with beat-note detectors, counter and oscilloscope with spectrum analyzer

Integrated specification

Central control unit from a computerized central system or control GUI must:

• allow control of the optical frequency comb operation and provide diagnostics and status

• allow the full control of the laser, incl. locks, parameters and status

• allow control of the wavelength meter

• be capable of providing live frequency measurements of cw lasers

• provide automatic calculation and plotting of Allan deviation from logged data

The laser system must be capable of working with lasers currently in possession of Code 5613, namely Toptica DL Pro and Toptica TA Pro lasers. This means that the frequency comb part of the system will be able to lock those lasers, operating at 780 nm, 795 nm and 1474 nm, and set the absolute frequency of those lasers.

See complete RFQ attached for additional details.

Attachments

Files attached to this notice, newest first
File Type Posted
REVISED RFQ N0017320QCY01 Amendment 1 - Attachment 1 Spec Attachment 2 Eval criteria.pdf PDF
1-13 RFQ N0017320QCY01.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Rydberg Rb with Difference Frequency Comb Lock Laser System Award Award Notice
Rydberg Rb with Difference Frequency Comb Lock Laser System This notice · Latest solicitation Solicitation
Rydberg Rb with Difference Frequency Comb Lock Laser System Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity