The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum is soliciting bids for explosion-proof rigid conduit and fittings designed for hazardous environments. The procurement includes various sizes of explosion-proof junction boxes (J Boxes) in T and X configurations ranging from 1/2 inch to 1 1/2 inch trade sizes, along with rigid conduit measuring 3/4 inch by 10 feet in length with threaded connections. All explosion-proof components must meet Class II, Division 1 and 2 specifications for Groups E, F, and G hazardous classifications, with female thread connections and covers included for the junction boxes. The solicitation was posted on August 11, 2025, with responses due by August 19, 2025, providing bidders with an eight-day response window. The procurement falls under NAICS code 331210 for Iron and Steel Pipe and Tube Manufacturing and PSC code 5630 for Pipe and Conduit, Nonmetallic.

This opportunity is designated as a Total Small Business set-aside, restricting competition to qualified small business entities. The quantities are substantial, including 100 units each of 1/2 inch and 3/4 inch junction boxes in both T and X configurations, 100 units of 1 inch X-shaped junction boxes, 50 units each of 1 1/4 inch junction boxes in both configurations, 50 units each of 1 1/2 inch junction boxes in both T and X shapes, and 200 units of 3/4 inch rigid conduit. The place of performance is located on Unnamed Road in McAlester, Oklahoma 74501, suggesting the materials will be delivered to a military installation or depot facility in that area. No incumbent contractor information or budget ranges were specified in the solicitation notice.

Notice text

GUAT16, 1/2 inch XP J Box, T with lid, Qty 100 1/2 inch trade size, Female thread gender, 3 hubs, Cover included, T shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GGUAX16, 1/2 inch XP J Box, X with lid, Qty 100 1/2 inch trade size, Female thread gender, 4 hubs, Cover included, X shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GGUAT26, 3/4 inch XP J Box, T with lid, Qty 100 3/4 inch trade size, Female thread gender, 3 hubs, Cover included, T shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GGUAX26, 3/4 inch XP J Box, X with lid, Qty 100 3/4 inch trade size, Female thread gender, 4 hubs, Cover included, X shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GRMC, 3/4 inch Rigid conduit, Qty 200 3/4 inch trade size, 10 ft length, Male threaded end and threaded female connector.GECXT-3M, 1 inch XP J Box, X with lid, Qty 1001 inch trade size, Female thread gender, 4 hubs, Cover included, X shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GGRT125, 1 1/4 inch XP J Box, T with lid, Qty 501 1/4 inch trade size, Female thread gender, 3 hubs, Cover included, T shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GGRX125, 1 1/4 inch XP J Box, X with lid, Qty 501 1/4 inch trade size, Female thread gender, 4 hubs, Cover included, X shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GGEJXT-5M, 1 1/2 inch XP J Box, X with lid, Qty 501 1/2 inch trade size, Female thread gender, 4 hubs, Cover included, X shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GGEJTT-5M, 1 1/2 inch XP J Box, T with lid, Qty 501 1/2 inch trade size, Female thread gender, 3 hubs, Cover included, T shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GUNF505, 1 1/2 inch Union, Female to female, Qty 1001 1/2 inch trade size, Female threads, Must be Class II, Div. 1 and 2, Groups E, F, GGEJTT -6M, 2 inch XP J Box, T with lid, Qty 502 inch trade size, Female thread gender, 3 hubs, Cover included, T shape, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, GRMC, 4 inch Rigid conduit, Qty 404 inch trade size, 10 ft length, Male threaded end and threaded female connector ELBD400, 4 inch XP Pulling elbow with lid, Qty 104 inch trade size, Female thread gender, 2 hubs, Cover included, Explosion proof, Conduit outlet body with cover. Must be Class II, Div. 1 and 2, Groups E, F, G

Similar open opportunities

Opportunity Agency Set-aside Responses due
Coupling assembly Rock Island, Illinois 61299 · NAICS 331210 MICC Fort Drum Total Small Business
Sch. 80 A53B Seamless, Pipe 1 C Tree Rd McAlester Ok Mcaap 74501 · NAICS 331210 MICC Fort Drum Total Small Business
Coupling assembly Rock Island, Illinois 61299 · NAICS 331210 MICC Fort Drum Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity