The Department of the Navy's Naval Sea Systems Command (NAVSEA) is conducting market research for the Naval Foundry & Propeller Center (NFPC) to identify alternative binder systems that can be utilized during their daily operations. NFPC currently uses Lino-Cure, an alkyd-oil three-part binder system, and is seeking information on other binder systems that may meet their needs. Respondents are asked to provide safety data sheets, details on the number of parts in their binder system, the workable time and cure time, and information on product expansion/contraction during curing. Respondents should also indicate whether their binder requires gas purging, contains any combustible constituents or environmental concerns, and if the current mixing machine setup would need to be replaced.

This is a pre-solicitation notice, and there is no set-aside designation. The main NAICS code is likely 325510 (Paint and Coating Manufacturing) and the PSC code is likely 6850 (Miscellaneous Chemical Specialties). There is no information provided on potential incumbents, award values, or budget ranges. The key dates are the response due date of April 19, 2024.

Notice text

The Naval Foundry & Propeller Center (NFPC) requires chemical products to be utilized during their daily operations. NFPC is currently utilizing Lino-Cure, an alkyd-oil three-part binder system. NSWCPD is conducting market research on behalf of NFPC to determine if there are alternative binder systems that meet NFPC’s needs.

Please respond to the following:

  1. Please provide the safety data sheets for your binder system.
  2. How many parts are in your binder system?
  3. What is the amount of time the binder and sand can be worked to shape the mold? Can the cure time be controlled?
  4. Do you have written or visual demonstration of product expansion/contracting during the cure time? If so, please provide.
  5. Can the resultant mold be easily modified or repaired, if necessary?
  6. Does your binder require gas purging to set?
  7. Are there combustible constituents in your binder system?  
  8. Do you utilize phenol, formaldehyde or any other environmental concern within your binder system?
  9. Would the current mixing machine setup require replacement of tanks, pipes, and tubes if switching over to your binder system?