Replace Door Control Unit
Open Pre-Solicitation Posted
- Solicitation number
- FA462027QC002
- Agency
-
Air Mobility Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 334519 Other Measuring and Controlling Device Manufacturing
- PSC
- 6110 Electrical Control Equipment
- Place of performance
- Fairchild AFB, Washington 99011, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Air Force, through the 92d Contracting Squadron at Fairchild AFB, Washington, under Air Mobility Command, is seeking sources sought responses from Total Small Business firms to replace a Door Control Unit, with responses due November 20, 2026. This sources sought notice is for planning only. It does not constitute a solicitation, pricing is not requested, and it is not a government commitment. Responses are not considered for award, and interested parties must respond separately to the resulting solicitation.
The requirement covers purchasing, removing, replacing, programming, and testing the primary internal logic controller for an Albany UltraFast high-speed commercial roll-up door in Building 1009 at Fairchild AFB. The contractor furnishes all labor, tools, equipment, and materials, including controls, hardware, and electrical connections. Per the draft SOW (FA462027QC002), the replacement controller requires anodized aluminum housing with IP55 protection, 3-phase 220-480V at 50-60 Hz supply, 24V DC control voltage, support for motors up to 3.0 HP, a vector-controlled frequency converter, a graphical display, an uninterrupted power supply, and configurable inputs and outputs. Work runs Monday through Friday, 0700-1630, excluding federal holidays. Contractor personnel must be U.S. citizens, follow Fairchild security regulations, and work under government escort in the secure work area. The government furnishes a qualified electrician for power disconnect and reconnect, site access, restrooms, and electrical power. Hazardous materials require material lists and Safety Data Sheets 14 days before work, secondary containment above 55 gallons, and removal upon completion.
Responses are limited to five pages and must include control unit specifications, feedback on which SOW areas the firm can and cannot complete, business name, address, CAGE code, and size and socioeconomic classification against the 600-employee size standard for NAICS 334519. Firms must be registered in SAM. The PSC is 6110, Electrical Control Equipment.
Notice text
PURPOSE: The purpose of the sources sought is to identify available authorized businesses to replace a Door Control Unit at Fairchild AFB.
This sources sought notice is for informational and planning purposes only. Pricing information is not being requested at this time. It does not constitute a solicitation and is not to be considered as a commitment by the government.
REQUIREMENT: This notice is issued by the U.S. Air Force, 92d Contracting Squadron, Fairchild AFB, WA. This sources sought is seeking to identify responsible potential sources to all necessary labor, tools, equipment and materials to purchase, remove/replace, program, and test the primary internal logic controller unit for the Albany UltraFast high-speed commercial roll-up door, to include the controls, hardware and electrical system connections at Building 1009 on Fairchild AFB, WA.. The replacement control unit must meet the specifications in accordance with the attached Statement of Work (DRAFT).
ANTICIPATED NAICS/SIZE STANDARD: This requirement falls under the NAICS Code of 334519, Other Measuring and Controlling Device Manufacturing, a size standard of 600 Employees.
SUBMISSION OF INFORMATION: All firms responding to this sources sought notice are advised that their response to this notice is not a request that will be considered for contract award. All interested parties will be required to respond to the resultant solicitation separately from their response to this sources sought notice. A responsible potential source shall have registered with the System for Award Management (SAM). The response should be no more than five pages providing the following information:
- Specifications of the Door Control Unit replacement services
- Provide feedback on what areas of the Statement of Work (DRAFT) your company can complete and areas your company cannot complete
- Business name, address, CAGE code
- Size and socioeconomic classification based on NAICS size standard
- If claiming a specific small business category, provide supporting documentation
- Point of contact including email and phone number
Please respond to this request by 20 November 2026 at 10:00 AM Pacific Time
Attachment 1: FA462027QC002 SOW (DRAFT)
Files
| File | Type | Posted |
|---|---|---|
| FA462027QC002 SOW (DRAFT).pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| FA27 Fall Arrest Inspection Services | Air Mobility Command | Total Small Business | |
| COMPUTER, FLIGHT CON_End_Item_KC-46_NSN_6615016536681KT_PN_822-1261-102 | Aviation | No set-aside | |
| PKA Relocatable Facility | Global Strike Command | Total Small Business | |
| GEARBOX, ACCESSORY D_End_Item_F108_NSN_2840011394075PN_PN_305-100-208-0 | Aviation | No set-aside | |
| Solicitation - Repair of the C-5 Automated Flight Control System Panel (AFCSP) and Communication/Navigation Panel (CNP) | Air Force Sustainment Center | No set-aside |