Repairs to the HVAC system at Coast Guard Air Station Atlantic City.
Closed Solicitation Posted
- Solicitation number
- 20121PR230000056
- Agency
-
Coast Guard
Department of Homeland Security
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- 4120 Air Conditioning Equipment
- Place of performance
- Egg Harbor Township, New Jersey 08234, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Solicitation has been updated.
Repairs to the HVAC system at Coast Guard Air Station Atlantic City located at Coast Guard Air Station Atlantic City, Atlantic City Intl. Airport, FAA Technical Center Building 350/351, Egg Harbor Township, NJ 08234-9393.
SCOPE of WORK:
- Inspect refrigerant lines and repair refrigerant leaks on Chiller Circuit 1.
- Conduct appropriate leak testing to ensure no refrigerant leaks on Chiller Circuit 1.
- Recharge Chiller Circuit 1 with required refrigerant (approx. 100lbs) and service unit as per manufactures guidance.
- Conduct visual inspection of glycol lines and repair leaks in glycol loops on heating and cooling side of the system throughout building. Remove and replace damaged insulation as necessary. Prior to commencing repairs, contractor shall provide the Coast Guard POCs with their plan to deal with the glycol in the HVAC system. There is approximately 1000 gallons of glycol pre side the cold and hot side of HVAC system totaling approximately 2000 gallons
- Repair or replace recirculation pump shaft seals (2 pumps)
- Replace 2 metering valves. These two valves are government furnished equipment. Contractor will need to provide required gaskets and hardware for installation.
- Upon completion of work, conduct inspection of glycol system and conduct appropriate leak and operational testing.
Wage rates apply.
This will be Firm Fixed Price Contract.
Lower Price Technical Acceptable (LPTA)
NAICS: 238220
Please see attached SOW, Wage determination, FAR clauses and SF18 Request for quote (RFQ).
Thank you
Update #1 ·
Repairs to the HVAC system at Coast Guard Air Station Atlantic City located at Coast Guard Air Station Atlantic City, Atlantic City Intl. Airport, FAA Technical Center Building 350/351, Egg Harbor Township, NJ 08234-9393.
SCOPE of WORK:
- Inspect refrigerant lines and repair refrigerant leaks on Chiller Circuit 1.
- Conduct appropriate leak testing to ensure no refrigerant leaks on Chiller Circuit 1.
- Recharge Chiller Circuit 1 with required refrigerant (approx. 100lbs) and service unit as per manufactures guidance.
- Conduct visual inspection of glycol lines and repair leaks in glycol loops on heating and cooling side of the system throughout building. Remove and replace damaged insulation as necessary. Prior to commencing repairs, contractor shall provide the Coast Guard POCs with their plan to deal with the glycol in the HVAC system. There is approximately 1000 gallons of glycol pre side the cold and hot side of HVAC system totaling approximately 2000 gallons
- Repair or replace recirculation pump shaft seals (2 pumps)
- Replace 2 metering valves. These two valves are government furnished equipment. Contractor will need to provide required gaskets and hardware for installation.
- Upon completion of work, conduct inspection of glycol system and conduct appropriate leak and operational testing.
Please see attached SOW and Wage determination.
Thank you
Files
| File | Type | Posted |
|---|---|---|
| SF18.pdf | ||
| Commercial Supplies Services Clauses Provisions FAC 2022-08.pdf | ||
| SOW Chiller 2023.pdf | ||
| Wage determinitation 15-4189.txt.pdf |