Repair stairway concrete at handrails
Award Notice Posted
- Solicitation number
- SP3100-08-Q-0064
- Agency
-
Distribution
Defense Logistics Agency, Department of Defense
- Set-aside
- Total Small Business
Opportunity facts
- Contract number
- SP3100-08-P-0845 Federal contract award
- NAICS code
- 238110 Poured Concrete Foundation and Structure Contractors
- PSC
- Not on record
- Place of performance
- Defense Distribution Depot Susquehanna New Cumberland, Pennsylvania 17070, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
AWARDED
Update #1 ·
The following summary is for the purpose of general information and is not intended to include and describe every feature or item or to define the scope of work.. It is expected the contractor will attend the site visit and thoroughly familiarize himself with the project.
Specifications and drawings will be provided when the Request for Quotation is issued.
Project Description: Repair stairway concrete at the handrail attachments to concrete stringers at parking lots 626 and 640, Bldgs.54 and 1.
This project is to provide the necessary material and labor as required by the plan and specifications to repair the stairway concrete at the handrail attachments to concrete stringers leading from S Avenue to parking lot 640 and from M Avenue to parking lot 626. Remove cracked grout and provide flexible sealant only at locations specified on the Plan. Also, repair concrete spall and handrail at locations specified on the Plan. All work to be performed in accordance with approved drawings and specifications.
Period of Performance:
Contractor shall commence work upon receipt of the Notice to Proceed (NTP) and shall complete the project to repair the stairway concrete at the handrail attachments and be ready for use within 45 days after receipt of Notice to Proceed.
Working Hours:
Normal hours of work shall be between 0730 and 1630, Monday through Friday excluding any Government holidays.
A pre-construction conference will be held within one week after NTP. The Contractor shall provide all initial submittal items indicated on the Technical Submittal Registers at the pre-construction meeting. Exceptions to this Submittal delivery requirement may be for materials that have a long-lead time.
NOTE: SD-01 Project Submittal Schedule This schedule must be provided at the preconstruction meeting for all initial submittal register items not provided at the Preconstruction meeting.
Contractor must provide Non-Technical submittals as outlined in Section 01330 as well as SD-60 Safety Plan & SD-62 Work Plan..
This acquisition is solicited as a Small Business Set-aside.
The NAICS Code for this procurement is 238110. The small business size standard is $13,000,000.
The magnitude of this construction effort is between $25,000 and $100,000.
The tentative timeframe for issuance of the Request for Quotation (RFQ) SP3100-08-Q-0064 for this requirement will be the week of 02 June 2008. A site visit will be conducted. The exact date and time for the site visit will be stated in the Request for Quotation.
Access to the Request for Quotation to include the specifications and drawings will only be made available to prospective offerors via the Federal Business Opportunities (FedBizOpps) website at http: www.fbo.gov. Hard copies of the solicitation will not be distributed.
Any questions concerning this project should be directed to the Contract Specialist Vonda DeBolt at Vonda.debolt@dla.mil All questions should be submitted in writing via email to the above.
Prospective offerors are cautioned concerning their responsibility to access the website for any amendments that may be issued under the Request for Quotation. There will be no advance notification of amendment issuance. Prospective offerors are advised to consult the website frequently to check for any amendments. Amendments may be issued up until the proposal due date. Failure to acknowledge amendments may render your proposal ineligible for award.
To receive awards resulting from solicitations issued after May 31, 1998, your company must be registered in the Central Contractor Registration (CCR) database. Contractor may obtain information on registration and annual confirmation requirements by calling 1-888-227-2423 or via the Internet at http:// www.ccr.gov. Prospective contractors shall also complete electronic annual representations and certifications at http://orca.bpn.gov in conjunction with required registration the CCR database.
All responsible offerors may submit a bid which shall be considered by this agency. The Government intends to award one contract as a result of this RFQ. Award will be made to the lowest responsive, responsible bidder. An offeror must be determined responsible according to the standards of FAR Subpart 9 to be eligible for award.
Files
| File | Type | Posted |
|---|---|---|
| STAIRWAY GROUT.pdf | ||
| STAIRWAY SAFETY REQUIREMENTS.pdf | ||
| STAIRWAY SPECIFICATIONS.pdf | ||
| STAIRWAY FORMWORK REINFORCEMENT.pdf | ||
| STAIRWAY PROJECT CLOSEOUT.pdf | ||
| RFQ 08Q0064.pdf | ||
| STAIRWAY CONCRETE.pdf | ||
| STAIRWAY SUBMITTAL PROCEDURES.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity