Repair Fire Hydrants / Valves
Closed Solicitation Posted
- Solicitation number
- FA480326R0028
- Agency
-
Air Combat Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Shaw AFB, SC 29152
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Combat Command seeks repair of fire hydrants and valves at Shaw Air Force Base, South Carolina, with proposals due August 12, 2026. The procurement is a 100% Small Business set-aside for NAICS 236220, Commercial and Institutional Building Construction.
Place of performance is Shaw AFB, SC. The construction magnitude is between $250,000 and $500,000. Period of performance does not exceed 141 days after issuance of Notice to Proceed. Site visit attendance was mandatory and was held July 7, 2026 at 9:00 A.M.; no additional site visits will be held. All prospective bidders were required to submit the Base Access Request Form (Attachment 10) no later than June 30, 2026, close of business. Questions and clarifications were due no later than July 14, 2026, close of business, with responses provided as an amendment no later than July 31, 2026, close of business. Questions and answers have been posted as Attachment 11 on PIEE. The PSC code is Z2JZ, Repair Or Alteration Of Miscellaneous Buildings. All times are Eastern Daylight Time. Proposals must be submitted no later than August 12, 2026, at 9:00 A.M. via PIEE. Contact SSgt Justin Moechnig (justin.moechnig@us.af.mil) and SrA Tariq Ellis (tariq.ellis@us.af.mil).
Notice text
2 versions
Update #2 · Latest ·
Project Title: Repair Fire Hydrants / Valves Project
Location: Shaw AFB
Period of Performance: Not to Exceed 141 days after issuance of Notice to Proceed.
Competition: This is a 100% Small Business set aside acquisition for NAICS 236220.
Magnitude of Construction is between $250,000 and $500,000.
A Site Visit for this requirement was held on 7 July 2026 at 9:00 A.M. on Shaw AFB, SC. No other Site Visit will be held for this requirement.
***Site Visit Attendance is mandatory for proposal submission.***
Note: This posting is a notice to the solicitation posting on PIEE. Through PIEE you will find all attachments, bid submission system and solicitation information.
Questions and answers have been posted as "Attachment 11 - Questions and Answers" on PIEE
Time Zone: All times are Eastern Daylight Time (EDT)
All correspondence shall be emailed to the Contract Specialist and Contracting Officer. All proposals must be submitted NLT 12 August 2026 at 9:00 A.M. SSgt Justin Moechnig (justin.moechnig@us.af.mil) and SrA Tariq Ellis (tariq.ellis@us.af.mil)
Update #1 ·
Project Title: Repair Fire Hydrants / Valves Project Location: Shaw AFB Period of Performance: Not to Exceed 141 days after issuance of Notice to Proceed. Competition: This is a 100% Small Business set aside acquisition for NAICS 236220. Magnitude of Construction is between $250,000 and $500,000. A Site Visit for this requirement will be held on 7 July 2026 at 9:00 A.M. on Shaw AFB, SC. All attendees must complete and submit Attachment 10 - Base Access Request Form, NLT COB30 June 2026. ***Site Visit Attendance is mandatory for proposal submission.*** Questions or request for Clarifications shall be submitted in writing to the Contracting Officer NLT COB 14 July 2026 and responses will be provided in the form of an Amendment as an additional attachment NLT COB 31 July 2026 Time Zone: All times are Eastern Daylight Time (EDT) All correspondence shall be emailed to the Contract Specialist and Contracting Officer. All proposals must be submitted NLT 12 August 2026 at 9:00 A.M. SSgt Braulio Ramirez Galvan (braulio.ramirez_galvan@us.af.mil) and SrA Tariq Ellis (tariq.ellis@us.af.mil)
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| FY27 MACC | Air Combat Command | Total Small Business | |
| Repair Naval Reserve Training Facility B3370 | Air Mobility Command | Total Small Business | |
| 2-STEP SEALED BID - TINKER AFB WWYK250019 Remove and Replace Fire Sprinkler in Plasma Booth Dust Collectors and Replace the Building F/A System, B3221 | Air Force Sustainment Center | Total Small Business | |
| WWYK260004 - repair structural integrity, B1134, post 34 & north wall | Air Force Sustainment Center | Total Small Business | |
| AMENDMENT-05 FD203026007725_FA811826R0047- REMAN SOLICITATION F-15 Fuel Tank Safety Relief Valve | Air Force Sustainment Center | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity