Repair Fire Hydrants and Valves
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- FA480325RO002
- Agency
-
Air Combat Command
Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Not on record
- Place of performance
- South Carolina 29152, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Combat Command is seeking a small business contractor to replace twenty-nine fire hydrants and perform associated plumbing work at Shaw Air Force Base in South Carolina. The project falls under NAICS code 236220 for Commercial and Institutional Building Construction and requires comprehensive water infrastructure replacement. Contractors must be prepared to submit a detailed capability statement including socioeconomic status, company contact information, CAGE code, DUNS number, and facility location. The market research notice indicates that electronic submissions are due by January 6, 2025, at 2:00 p.m. EST, with responses to be sent directly to SrA Margret Ogbuozobe or SSgt Shaun Gann. While this is currently a sources sought notice for market research, potential solicitation details will be posted on www.sam.gov if the procurement moves forward.
The opportunity is designated as a total small business set-aside with a small business size standard of $45 million. The project scope involves installing new left-turn open style and three-way style fire hydrants, complete with isolation valves, thrust blocks, and metal water bridge loaded valve boxes with concrete collars. Contractors will be required to paint hydrant bonnets in specific colors based on location and perform flow tests on new installations. The total project timeline is 111 calendar days, broken down into 30 days of preparation, 60 days of construction, and 21 days for closeout. Specific technical requirements include compliance with multiple standards such as UFC, UFGS, IBC, IPC, SCDHEC, NEC, NESC, NFPA, and Shaw AFB Design and Construction Standards, with a minimum one-year warranty required for all work performed.
Notice text
The purpose of this requirement is for the contractor to replace twenty-nine (29) fire hydrants, to include applicable plumbing work for the hydrants, IAW Statement of Work, dated5 Dec 24.
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Repair Valves/Hydrants Base Wide | Solicitation | |
| Replace Fire Hydrants | Pre-Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| FY27 MACC | Air Combat Command | Total Small Business | |
| Fire Alarm/Suppression Inspection, Testing, and Maintenance | Air Force Research Laboratory | No set-aside | |
| 2-STEP SEALED BID - TINKER AFB WWYK250019 Remove and Replace Fire Sprinkler in Plasma Booth Dust Collectors and Replace the Building F/A System, B3221 | Air Force Sustainment Center | Total Small Business | |
| Repair Naval Reserve Training Facility B3370 | Air Mobility Command | Total Small Business | |
| Inspection of Fire Extinguishers and Suppression Systems for AMXG at Hill AFB, Utah | Air Force Sustainment Center | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity