Remediation Services - SPCC Tank Testing

Awarded Award Notice Posted

Solicitation number
W911RP-14-R-0004
Agency
Joint Munitions Command Army Materiel Command, Department of Defense
Awarded
to Pollution Management Inc.
Set-aside
No set-aside

Opportunity facts

Contract number
W911RP-14-C-0004 Federal contract award
NAICS code
562910 Remediation Services
PSC
Not on record

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

Added: Jan 09, 2014 3:25 pm Modified: Sep 03, 2014 3:31 pmTrack Changes Furnish required services for Non-destructive integrity testing of specific in service above ground storage tank testing, and removal of other out of service and underground storage tanks.

Update #1 ·

Added: Jan 09, 2014 3:25 pm NOTICE - The Previous ASFI synopsis was W911RP-13-R-0011, change to W911RP-14-R-0004 - The Contracting Division, Pine Bluff Arsenal (PBA), Pine Bluff, Arkansas 71602-9500, has a requirement for a contractor to provide all labor, equipment and supplies to perform all aspects of CAT-I tank testing and CAT-II tank residue removal/disposal of tank binding and removal. The contractor must be certified in Steel Tank Institute (STI) standard SP001 to perform non-destructive integrity testing of in-service (CAT-1) above ground storage tanks (ASTs) to include the cleaning, blinding and removal of specific out-of-service (CAT-II) ASTs and underground storage tanks (USTs) at PBA. Without draining the tanks and without significant disruption of PBA's operation, the contractor will test and evaluate each AST and their respective valves and piping, in accordance with applicable Steel Tank Institute (STI) or American Petroleum Institute (API) standards with one of the following external, non-destructive integrity testing technique as stated within the Federal regulations 40 CFR 112.8 (6): (1) Hydrostatic testing (2) Radiographic Testing Ultrasonic testing (d) Acoustic testing or (e) another system of noon-destructive shell testing. After such testing completed, the contractor will replace or reinstall any tank insulation or out shell material that was removed during testing. The contractor shall develop a report of all findings; recommendations regarding the continued use of the tank and test results and will, at the completion of the project, submit the report, in electronic (compact disk) and hard copy format to PBA Environmental. All work shall be performed in accordance with Pine Bluff Arsenal's Scope of Work. The North American Industry Classification System NAICS code 562910 (19.0 M). This is a One-Hundred (100%) Small Business Set-Aside. All contractors must be registered in SAM's. Solicitation will be posted on the www.fbo.gov website. Solicitation W911RP-14-R-0004 will be issued o/a 14 February 2014 with a closing date of o/a 20 Mar 2014. Solicitation may be obtained via email request to retha.j.sprinkle.civ@mail.mil . Point of contact is also Retha Sprinkle, Contract Specialist, 870-540-3054, Fax No: 870-540-3730.

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity