RECOVERY Z--Communication Closet A/C Upgrades
Award Notice Posted
- Solicitation number
- VA-263-10-RA-0098
- Agency
-
Veterans Integrated Service Network 23
Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to Pa Construction Group
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- Contract number
- VA263RA0950 Federal contract award
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Not on record
- Place of performance
- One Veterans Drive Minneapolis, MN 55417 USA
Notice details come from SAM.gov. Updated .
Notice text
RECOVERY ACT PROJECT
RFP VA263-09-RA-0098
NIACS 236220
Z - CONSTRUCTION PROJECT - COMMUNICATION CLOSETS A/C UPGRADE - DESIGN-BUILD
A. Base Item: Base Bid: Base Bid: Supply and return piping and cooling to multiple communication closets.
1. Provide design and construction of 2 " supply and return piping for the existing high temperature condenser water system to accommodate heat rejection from some of the closets. See concept drawing.
2. Provide cooling for the following closets: 1N102-70, 1T102-70, 2J132A-70, 3H123-70, 3Q118F-70, 4T104-70, BD101A-70, and BT105-70. See spreadsheet in Solicitation Documents that lists recommended cooling solution.
3. Provide new gypsum board ceilings as indicated in this scope of work for 2J132A-70, 3Q118F-70, and BD101A-70. Provide other architectural, mechanical, electrical, and structural features as indicated in this scope of work.
4. Provide fire sprinklers in 2J132A-70, 3Q118F-70, and BD101A-70.
B. Option #1: Cooling for communication closet, BD101D-70 using water-cooled DX unit.
1. Provide new cooling system for communication closet BD101D-70 using DX water-cooled unit that provides 3520 BTUH of sensible cooling at the entering air and condenser water conditions indicated above.
2. Provide new gypsum board ceiling as indicated in this scope of work.
3. Provide other architectural, mechanical, electrical, and structural features as indicated in this scope of work.
4. Provide fire sprinkler in BD101D-70.
C. Option #2: Cooling for communication closet, BD101E-70 using water-cooled DX unit.
1. Provide new cooling system for communication closet BD101E-70 using DX water-cooled unit that provides 3520 BTUH of sensible cooling at the entering air and condenser water conditions indicated above.
2. Provide new gypsum board ceiling as indicated in this scope of work.
3. Provide other architectural, mechanical, electrical, and structural features as indicated in this scope of work.
4. Provide fire sprinkler in BD101E-70.
D. Option #3: Cooling for communication closet, 1D120C-70 using water-cooled DX unit.
1. Provide new cooling system for communication closet 1D120C-70 using DX water-cooled unit that provides 5100 BTUH of sensible cooling at the entering air and condenser water conditions indicated above.
2. Provide new gypsum board ceiling as indicated in this scope of work.
5. Provide other architectural, mechanical, electrical, and structural features as indicated in this scope of work.
E. Option #4: Cooling for communication closet BT102-70 using water-cooled DX unit.
1. Provide new cooling system for communication closet BT102-70 using DX water cooled unit that provides 7100 BTUH of sensible cooling at the entering air and condenser water conditions indicated above. This unit shall serve BT102-70 and the electrical room it is located in, BT101-70.
2. Unit air shall be ducted from the electrical room to the communication closet and registers and grilles shall be installed to cool both the closet and the electrical room.
3. Provide other architectural, mechanical, electrical, and structural features as indicated in this scope of work.
F. Option #5: Cooling for communication closet, BH105-70 using water-cooled DX unit.
1. Provide new cooling system for communication closet BH105-70 using DX air cooled cooling unit that provides 5100 BTUH of sensible cooling at the entering air and condenser water conditions indicated above. This unit shall serve BH105-70 and the electrical room it is located in, BH106-70.
2. Unit air shall be ducted from the electrical room to the communication closet and registers and grilles shall be installed to cool both the closet and the electrical room.
3. Provide other architectural, mechanical, electrical, and structural features as indicated in this scope of work.
G. Option #6: Cooling for communication closet, BT104-70 using new VAV terminal.
1. Provide new cooling system for communication closet BT104-70 using a VAV terminal that is sized for 300 CFM.
2. Provide other architectural, mechanical, electrical, and structural features as indicated in this scope of work.
3. Connect to ductwork served by AHU-37 and return-exhaust fan RF-30.
The VA has scheduled a site visit for this project on February 18, 2010 at 9:00 am at the VA Medical Center, Facility Engineering Service, Project Section, Room BR-145. Solicitation and scope of work documents are expected to be available at www.fbo.gov on or about February 5, 2010.
Tentative Schedule:
Request for proposal issued 2-8-10
Site walks 2-18-10
Proposal submitted 3-8-10
Board review and recommendation 3-15-10
Contract award 3-16-10
Notice to proceed (NTP) - Design 3-29-10
35% Design package submitted 5-28-10
35% VA design review complete 6-18-10
35% Design review meeting 6-21-10
95% Design package submitted 7-20-10
95% VA design review complete 8-3-10
95% Design review meeting 8-9-10
100% Design complete 8-23-10
100% Backcheck complete 8-30-10
Notice to proceed (NTP) - Construction 9-6-10
Construction start 9-16-10
Construction complete 12-16-11
Note: A construction notice to proceed (NTP) will not be issued until the 100% back check is complete and the COTR has notified the Contracting Officer that the second NTP can be issued.
Schedule Objectives - The anticipated completion of this project is 262 calendar days after "Notice to Proceed (NTP) - Design."
In accordance with the VA Acquisition Regulations (VAAR 836.204) Disclosure of the Magnitude of Construction Projects, the range for this project is between $250,000 and $500,000. Liquidated Damages: $200.00 per calendar day, including holidays and weekends. NAICS 236220 - $31.0M applies.
In accordance with PL 109-461 this project is 100% set-aside for Service disabled veteran-owned small business (SDVOSB) concerns.
All responsible and interested offerors should submit a proposal in accordance with RFP VA263-09-RA-0098. Offerors are to complete and submit their proposals (original and one copy required) not later than Monday, March 8, 2010 at 4:30 p.m. CT.
POC: Michael Owen, Contracting Officer, E-mail: michael.owen@va.gov Facsimile or other electronic methods WILL NOT be acceptable for the purposes of submitting a proposal. If proposal is to be mailed or delivered by third party courier the address is: Department of Veterans Affairs, Minneapolis Contracting and Purchasing Office, 708 South Third Street, Suite 200E, Minneapolis, MN 55415 ATTN: M. Owen.
If proposal is to be hand delivered the delivery address is the same as above.
Files
| File | Type | Posted |
|---|---|---|
| VA-263-10-RA-0098-0004000.DOC | DOC document | |
| VA-263-10-RA-0098-0003001.DOC | DOC document | |
| VA-263-10-RA-0098-0003002.DOC | DOC document | |
| VA-263-10-RA-0098-0003000.DOC | DOC document | |
| VA-263-10-RA-0098-0002000.DOC | DOC document | |
| VA-263-10-RA-0098-0001000.DOC | DOC document | |
| VA-263-10-RA-0098-002.ZIP | ZIP file | |
| VA-263-10-RA-0098-001.ZIP | ZIP file | |
| VA-263-10-RA-0098-000.DOC | DOC document |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity