RECOVERY - XUMU061189B - Replace HVAC Units & Controls, Military Clothing Sales Fac
Award Notice Posted
- Solicitation number
- SABER_XUMU06-1189B
- Agency
-
Air Force Space Command
Air Force, Department of Defense
- Awarded
- to ACE Engineering Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- FA4610-04-D-0014-0097 Federal contract award
- NAICS code
- 236220 Commercial and Institutional Building Construction
- PSC
- Not on record
- Place of performance
- 1515 Iceland Ave, Room 150 Building 8500 Vandenberg, California 93437, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
TAS::57 3404::TAS ARRA XUMU 06-1189B, Replace HVAC Units & Controls at AAFES BX, fully funded by Recovery Act.
The scope of work for this project to replace HVAC Units & Controls at AAFESS BX in building 10400, VAFB, CA includes: Removing existing pneumatic controls system/components.; Provide and install a new HVAC control system per the attached design; Removing and replacing AHU-1 to include the chilled/hot water coils, actuators, valves, dampers and associated equipment; Removing and replacing AHU-2 to include the chilled/hot water coils, actuators, valves, dampers and associated equipment; Removing and replacing AHU-3 to include the chilled/hot water coils, actuators, valves, dampers and associated equipment; Removing and replacing RF-1 to include all associated equipment; Removing and replacing AHU-4 to include DX A/C coil, Hot water coil, actuators, valves, dampers and associated equipment; Removing and replacing AHU-5 to include Hot water coil, actuators, valves, dampers and associated equipment. Contractor will Install a new A/C coil and condensing unit sized appropriately; Installing additional controls; Removing and replacing AHU-6 to include DX A/C coil, Hot water coil, actuators, valves, dampers, condensing unit and associated equipment; Removing and replacing AHU-7 to include DX A/C coil, Hot water coil, actuators, valves, dampers and associated equipment; Removing and replacing AHU-8 to include Hot water coil, actuators, valves, dampers and associated equipment; Removing and replacing all variable frequency drives; Removing and replacing all pumps; Removing and replacing all dampers; Existing chiller, boiler and ducts to remain; Installing fire detection devices as required. To include dampers and unit shutdown; Installing Block wall that matches the existing wall at facility, around the chiller with wooden gates; Air Balance all air handlers, and Balance all water lines.
Update #1 ·
RECOVERY - THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER THE SABER PROGRAM, AT VANDENBERG AFB, CA.
RECOVERY - XUMU 06-1189B, REPLACE HVAC UNITS & CONTROLS AT AAFES BX
TASK ORDER MAGNITUDE: $500,000 - $1,000,000