RECOVERY - XUMU061189B - Replace HVAC Units & Controls, Military Clothing Sales Fac

Award Notice Posted

Solicitation number
SABER_XUMU06-1189B
Agency
Awarded
to ACE Engineering Inc.
Set-aside
No set-aside

Opportunity facts

Contract number
FA4610-04-D-0014-0097 Federal contract award
NAICS code
236220 Commercial and Institutional Building Construction
PSC
Not on record
Place of performance
1515 Iceland Ave, Room 150 Building 8500 Vandenberg, California 93437, United States

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

TAS::57 3404::TAS ARRA XUMU 06-1189B, Replace HVAC Units & Controls at AAFES BX, fully funded by Recovery Act.

The scope of work for this project to replace HVAC Units & Controls at AAFESS BX in building 10400, VAFB, CA includes: Removing existing pneumatic controls system/components.; Provide and install a new HVAC control system per the attached design; Removing and replacing AHU-1 to include the chilled/hot water coils, actuators, valves, dampers and associated equipment; Removing and replacing AHU-2 to include the chilled/hot water coils, actuators, valves, dampers and associated equipment; Removing and replacing AHU-3 to include the chilled/hot water coils, actuators, valves, dampers and associated equipment; Removing and replacing RF-1 to include all associated equipment; Removing and replacing AHU-4 to include DX A/C coil, Hot water coil, actuators, valves, dampers and associated equipment; Removing and replacing AHU-5 to include Hot water coil, actuators, valves, dampers and associated equipment. Contractor will Install a new A/C coil and condensing unit sized appropriately; Installing additional controls; Removing and replacing AHU-6 to include DX A/C coil, Hot water coil, actuators, valves, dampers, condensing unit and associated equipment; Removing and replacing AHU-7 to include DX A/C coil, Hot water coil, actuators, valves, dampers and associated equipment; Removing and replacing AHU-8 to include Hot water coil, actuators, valves, dampers and associated equipment; Removing and replacing all variable frequency drives; Removing and replacing all pumps; Removing and replacing all dampers; Existing chiller, boiler and ducts to remain; Installing fire detection devices as required. To include dampers and unit shutdown; Installing Block wall that matches the existing wall at facility, around the chiller with wooden gates; Air Balance all air handlers, and Balance all water lines.


Update #1 ·

RECOVERY - THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER THE SABER PROGRAM, AT VANDENBERG AFB, CA.

RECOVERY - XUMU 06-1189B, REPLACE HVAC UNITS & CONTROLS AT AAFES BX


TASK ORDER MAGNITUDE: $500,000 - $1,000,000