Recovery-- repair fire detection system lodging 1020, NKAK9610141

Award Notice Posted

Solicitation number
F2S3CZ9036A002
Agency
Awarded
to Arnold Electric Company, Inc.
Set-aside
No set-aside

Opportunity facts

Contract number
FA4460-07-D-0014-5005 Federal contract award
NAICS code
238210 Electrical Contractors and Other Wiring Installation Contractors
PSC
Not on record
Place of performance
642 Thomas Ave Lrafb, Arkansas 72099, United States

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

"RECOVERY -- ""In compliance with the transparency and accountability requirements associated with the supplemental appropriations provided by the American Recovery and Re-Investment Act of 2009, Pub.L. 111-5."" ""THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THE GOVERNMENT POSTS THIS AWARD NOTICE TO ISSUE DELIVERY ORDERS UNDER ESTABLISHED IDIQ CONTRACT # FA4460-07-D-0014 WITH ARNOLD-BLEVINS ELECTRIC CO, INC.""
THE DELIVERY ORDER ISSUED AGAINST SAID CONTRACT IS AS FOLLOWS:
FA4460-07-D-0014-5005 NKAK 96-1014-1 - INSTALL AUTO FIRE DETECTION SYSTEM B1020 - ($115,270.39)

Update #1 ·

RECOVERY - THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS ONLY AVAILABLE TO THE CONTRACTOR UNDER THE LITTLE ROCK AFB, ARKANSAS FIRE DETECTION, INDEFINITE DELIVERY/INDEFINITE QUANTITY CONTRACT FA4460-07-D-0014 AWARDED TO ARNOLD AND BLEVINS ELECTIC COMPANY.

THIS PROJECT CALLS FOR THE INSTALLATION OF AUTOMATIC FIRE DETECTION SYTEM IN BULDING 1020, LITTLE ROCK AFB, AR. TO INCLUDE, BUT NOT LIMITED TO: AN ADDRESSABLE FIRE ALARM WITH NEW BT-XF TRANSCEIVER TO CORRECT DEFICIENCIES. EACH 120VAC DETECTOR IN BUILDING 1020 WILL BE REPLACED WITH 24VDC ADDRESSABLE UNITS WITH SOUNDING BASE UNITS. EXISTING ATTIC HEAT DETCTOR ZONE SHALL BE MONITORED WITH A MODULE IN THE AIR CONDITIONED SPACE BETWEEN THE DROP IN THE CEILING AND THE ATTIC DECK. EXISTINGS ZONES WILL BE REWIRED SO THAT NO MORE THAN SIX ATTIC HEAT DETECTORS ARE MONITORED BY EACH MODULE. EXISTING HEAT DETECTORS IN STAIRWELLS, COMMON AREAS AND ABOVE CEILING IN HALLWAYS SHALL BE MONITORED WITH AN ADDRESSABLE MONITOR MODULE. NO MORE THAN SIX CONVENTIONAL HEAT DETECTORS SHALL BE MONITORED BY ONE UNIT. STROBES SHALL BE ADDED TO THE FIRST FLOOR PUBLIC RESTROOM AND LOUNGE, SECOND FLOOR PUBLIC RESTROOM AND THE SECOND FLOOR FITNESS ROOM. VANDAL GUARDS WILL BE ADDED TO ALL PULL STATIONS.