RECOVERY - QYZH060047 - Refurbish Hangar Door Tracks, B1330 & 1332

Award Notice Posted

Solicitation number
FA4897-06-D-3005
Agency
Awarded
to C-2 Construction Inc.
Set-aside
No set-aside

Opportunity facts

Contract number
FA4897-06-D-3005-0064 Federal contract award
NAICS code
236220 Commercial and Institutional Building Construction
PSC
Not on record
Place of performance
Mountain Home AFB Mountain Home, Idaho 83648, United States

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

TAS::57 3404::TAS -- In compliance with the transparency and accountability requirements associated with the supplemental appropriations provided by the American Recovery and Re-Investment Act of 2009, Pub.L. 111-5, the Government posts this award notice on the issuance of a task order under an established Simplified Acquisition of Base Engineer Requirement (SABER) contract FA4897-06-D-3005, CE project # QYZH 06-0047.  The contractor shall furnish all plant, labor, equipment, materials, personnel, and supervision necessary to refurbish the hangar doors on 1330 and 1332.  All work will be accomplished in accordance with the Statement of Work (SOW), dated 10 March 2009, and the terms and conditions of the existing SABER contract.

Update #1 ·

THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO THE CONTRACTOR UNDER THE CURRENT MOUNTAIN HOME AFB, ID SIMPLIFIED ACQUISITION OF BASE ENGINEERING REQUIREMENTS (SABER) INDEFINITE DELIVERY/INDEFINITE DELIVERY (IDIQ) CONTRACT. (FA4897-06-D-3005)

SABER 2009 STIMULUS PROJECT: The project calls for the removal of existing concrete, rails, and hardware 9" below hangar floor finish surface, 346' long by 4' wide. Install #4 vertical dowels 18" O.C., epoxy in to existing concrete. Install new #20 ASCE rails and hardware. Install PVC sleeves to accept hydronic heat lines along length of rails. Install continuous length PEX-AL-PEX tubing with O2 barrier in PVC sleeves and couple t manifolds at ends. Connect new rail heat tubing to existing heat lines at each end. Install traffic rated covers over manifolds. Install backer rod and urethane sealant where new concrete abuts existing concrete. Perform all necessary related work for a complete and usable system. The magnitude of this project is between $250,000 and $500,000. This notice of intent is not a request for competitive quotes.