RECOVERY--N--PROJECT NUMBER 37148, Repair/Replace Undersized Central Plant Equipment Serving Smoke Bomb Hill

Award Notice Posted

Solicitation number
W912DY10N0217
Agency
Awarded
to Johnson Controls Building Automation Systems, LLC
Set-aside
No set-aside

Opportunity facts

Contract number
W912DY-09-D-0037-0054 Federal contract award
NAICS code
541512 Computer Systems Design Services
PSC
Not on record

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

This Task Order is to survey, analyze field data, prepare engineering design drawings and specifications, install equipment or complete repairs per the approved design. The Contractor shall furnish the materials and labor required for inspecting and upgrading HVAC equipment and Direct Digital Controls in Building H-3531 at Ft. Bragg, NC. Direct Digital Controls shall be inspected and upgraded on HVAC systems as specified in Attachment 4 and 5. The Contractor shall repair and replace controls and incidental electrical and structural elements as needed for a complete and useable system. The Contractor shall survey the hardware necessary for this project and validate the operational effectiveness of any equipment to be reused. All surveys will be coordinated with Ft. Bragg maintenance personnel. The HVAC equipment and LonWorks system shall be for a complete operational system as defined in Attachment No. 4 and 5 and per the specifications listed in Attachment No. 1. In addition, this project includes design and installation of addition direct digital control (DDC) system equipment in order to remotely control this equipment from the existing Ft. Bragg LCS server located in 3-1634.

Update #1 ·

RECOVERY - PER FAR 5.7 THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY; THEREFORE FAR 5.203 DOES NOT APPLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTOR(S) UNDER THE CURRENT CONTRACT NUMBER(S): W912DY-09-D-0035 through W912DY-09-D-0041

This Task Order is to survey, analyze field data, prepare engineering design drawings and specifications, install equipment or complete repairs per the approved design. The Contractor shall furnish the materials and labor required for inspecting and upgrading HVAC equipment and Direct Digital Controls in Building H-3531 at Ft. Bragg, NC. Direct Digital Controls shall be inspected and upgraded on HVAC systems as specified in Attachment 4 and 5. The Contractor shall repair and replace controls and incidental electrical and structural elements as needed for a complete and useable system. The Contractor shall survey the hardware necessary for this project and validate the operational effectiveness of any equipment to be reused. All surveys will be coordinated with Ft. Bragg maintenance personnel. The HVAC equipment and LonWorks system shall be for a complete operational system as defined in Attachment No. 4 and 5 and per the specifications listed in Attachment No. 1. In addition, this project includes design and installation of addition direct digital control (DDC) system equipment in order to remotely control this equipment from the existing Ft. Bragg LCS server located in 3-1634.