RECOVERY- KWRD020015- Repair Cast Iron Pipe Main Base
Award Notice Posted
- Solicitation number
- HOLL-09-S-2841(KWRD020015)
- Agency
-
Air Education and Training Command
Air Force, Department of Defense
- Awarded
- to Ch2M Hill Constructors Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- FA3002-08-D-0005-0008 Federal contract award
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- Not on record
- Place of performance
- Holloman AFB, NM, New Mexico, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
Competitive award under existing SATOC ID/IQ contract.
Update #1 ·
RECOVERY - "In compliance with the transparency and accountability requirements associated with the supplemental appropriations provided by the American Recovery and Re-Investment Act of 2009, Pub.L. 111-5, the Government posts this presolicitation notice of intent to issue a task order under an established Indefinite Delivery Indefinite Quantity (IDIQ) type contract with the Prime Contractors presently assigned to the Sustainment, Restoration & Modernization Acquisition Task Order Contract (SATOC) which is operated by HQ AETC CONS LGCT office, c/o HQ AFCESA CONS CEKC at Tyndall AFB, FL. This notice is provided for INFORMATION PURPOSES ONLY.
This project calls for Repair of cast iron water lines base, phase 1, Holloman AFB, NM, as stated in the presolicitation title. The Government intends to issue a task order to one of the SATOC Prime Contractors under the SATOC IDIQ. The SATOC Prime Contractors main points of contact are listed on the attached SATOC Prime Spreadsheet (see attachment). Companies interested in subcontracting opportunities should contact the companies listed on this form.
The purpose of this project is to replace existing pipeline at Holloman AFB. The contractor shall complete development of plans and specifications in accordance with defined levels of effort necessary to construct the project. Project requirements include: installation of 10 diameter PVC piping, with a pressure rating of 125 psi; installation of air relief valves, gate valves, and thrust blocks, all of which shall be resilient seated and of steel construction; and cathodic protection, including test ports, shall be provided.
Attachment (1): SATOC Contractors List