Added: May 21, 2009 5:44 pm
This firm fixed price award is against a previously existing mulitiple award SABER IDIQ contract competed under the 8(a) set-a-side program. The contractor shall perform all services necessary to accomplish complete and functional installation of the proposed project. The work shall be in accordance with the SABER contract specifications, associated drawings and additional requirements of the task order statement of work.
REQUIREMENT: The Contractor shall provide all labor, material, equipment and incidentals necessary to install sump pumps with high level alarms in the crawl spaces of homes located in Jupiter Village. Major items of work shall consist of:
01 - EXCAVATION: Dirt in the crawl spaces of homes is sloped to a low point. Contractor is to excavate enough soil to allow installation of a sump basin with gravel. Care will need to be taken while hauling excavated soil through the housing units for disposal off base.
02 - Sump Pump: Contractor is to line the excavation with filter fabric. Place an 18" X 24" deep perforated sump basin with at least 4" of washed drainage gavel around all sides and below. Place a 1/3 HP brass sump pump with auto float and pipe discharge to connect into sanitary sewer line stack located in the crawl space. Discharge Pipe will require a check valve.
03 - ELECTRICAL: Contractor will be required to run conduit, wire and associated hardware to install an outlet for the sump pump and a light with switch in the crawl space. Also need to install a high level alarm on sump basin with alarm panel located in the mechanical room. Alarm panel will have both audible and lights signals.