RECOVERY - FTEV071041 - Repair 6 SOS Hangar/Doors, Bldg 90825

Award Notice Posted

Solicitation number
FA4417-09-R-0022
Agency
Awarded
to HCG SCC JV, LLC
Set-aside
No set-aside

Opportunity facts

Contract number
FA4417-09-C-0009 Federal contract award
NAICS code
236220 Commercial and Institutional Building Construction
PSC
Not on record
Place of performance
1 Socons Hurlburt Field, Florida 32544, United States

Notice details come from SAM.gov. Updated .

Notice text

3 versions

Update #3 · Latest ·

Contract FA4417-09-C-0009 awarded on 18 Jun 09 from solicitation FA4417-09-R-0022. Awardee: HCG-SCC JV, LLC Award Amount: $419,700.00 Description of work: Design/Build hangar doors. The doors shall be electrically powered and operate at a minimum speed of FPM. In the event of a power loss, personnel must be able to override the electrical system and move the doors manually. Provide brackets to allow attachment of straps and/or chains to allow manual movement of the doors. Provide braking system acceptable to and approved by the Contracting Officer. Provide all electrical support and design to connect to the existing electric system in the building. A warning hor and visual alarm that indicates the structure is moving or about to be moved shall be provided and shall differ from the existing horn and visual alarm used in the fire suppression system. A safety edge shall be provided to prevent the doors from closing in the event of an emergency. The prime contractor and the supplier shall provide a written warranty in a form acceptable to and approved by the Contracting Officer, that the doors and all components associated with the doors shall be free from defects in materials and workmanship for a period of two years from the date of acceptance by the government.

Update #2 ·

Contract FA4417-09-C-0009 awarded on 18 Jun 09 from solicitation FA4417-09-R-0022.



Awardee: HCG-SCC JV, LLC



Award Amount: $419,700.00



Description of work: Design/Build hangar doors. The doors shall be electrically powered and operate at a minimum speed of FPM. In the event of a power loss, personnel must be able to override the electrical system and move the doors manually. Provide brackets to allow attachment of straps and/or chains to allow manual movement of the doors. Provide braking system acceptable to and approved by the Contracting Officer. Provide all electrical support and design to connect to the existing electric system in the building. A warning hor and visual alarm that indicates the structure is moving or about to be moved shall be provided and shall differ from the existing horn and visual alarm used in the fire suppression system. A safety edge shall be provided to prevent the doors from closing in the event of an emergency. The prime contractor and the supplier shall provide a written warranty in a form acceptable to and approved by the Contracting Officer, that the doors and all components associated with the doors shall be free from defects in materials and workmanship for a period of two years from the date of acceptance by the government.

Update #1 ·

RECOVERY - THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY!


THIS OPPORTUNITY HAS BEEN MADE AVAILABLE TO A SELECTED AND APPROVED 8(A) SOLE SOURCE CONTRACTOR.  SOLICITATION NUMBER: FA4417-09-R-0022.

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors