RECOVERY - FSPM051413 - Repair Roof Vehicle Maintenance, Building 3511 and RECOVERY - FSPM081215 - Repair Roof Fuel Facility, Building 2110
Award Notice Posted
- Solicitation number
- FA930107D0002-FSPM051413-FSPM081215
- Agency
-
Air Force Test Center
Air Force Materiel Command, Department of Defense
- Awarded
- to Vanguard Construction, Inc.
- Set-aside
- Competitive 8(a)
Opportunity facts
- Contract number
- FA9301-07-D-0002-0024 Federal contract award
- NAICS code
- 238160 Roofing Contractors
- PSC
- Not on record
- Place of performance
- 5 South Wolfe Avenue Edwards AFB, California 93524, United States
Notice details come from SAM.gov. Updated .
Notice text
Synopsis:
RECOVERY - THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER ROOF IDIQ CONTRACT NUMBER FA9301-07-D-0002. Contractor Vanguard Construction Inc. P.O. Box 239, Arroyo Grande, CA 93421-0239. It is the Contracting Squadron's intent to award a firm-fixed price task order to the above contractor. Davis-Bacon wages presently in effect for California, CA070031(Modification 12) 08/24/2007& CA070013 (Modification 9) 08/17/2007 will prevail. These acquisitions are subject to the North American Industry Classification Code 238320 and the annual size standard is $14.0 million.
RECOVERY - Repair Roof Vehicle Maintenance, Building 3511 - FSPM051413
THE PROJECT DESCRIPTION IS AS FOLLOWS:
The work to be accomplished is furnish all labor, materials, equipment, and supervision required to repair the built-up roof Bldg 3511. Remove gravel balast and elastomeric coating. Install ¼" dense deck and single ply roofing system. Install wood nailers. Replace metal flashingsand drip edges. Install walkpads to equipment from roof ladder. Paint exposed metal flashings and drip edges "Redwood" and Paint roof top equipment Marble Cream. Roof mastics around penetrations and flashings are positive for asbestos. For roofs with a slope of 2:12 or less- "Use roofing materials having a Solor Reflective Index (SRI) equal to or greater than 78." For roof with greater than 2:12- " Use roofing materials having a Solar Reflectance Index (SRI) equal to or greater than 29." The magnitude of the project is between $25,000 and $100,000.
RECOVERY - Repair Roof BX Gas Station, Building 2110 - FSPM081215
THE PROJECT DESCRIPTION IS AS FOLLOWS:
The work to be accomplished is furnish all labor, materials, equipment, and supervision required to repair the built-up roof Bldg 2110. Install ¼" dense deck and single ply roofing system. Install wood nailers. Replace parapet caps with prefinished metal (Redwood). Replace metal flashings, scuppers, and drip edges. Install pre-finished rain gutters, down spouts and splash blocks on backside of facility from access ladder. Paint rooftop equipmaent (Marble Cream). Roof mastics around penetrations and flashings, as well as base flashing along vertical edges are positive for asbestos. For roofs with a slope of 2:12 or less- "Use roofing materials having a Solor Reflective Index (SRI) equal to or greater than 78." For roof with greater than 2:12- " Use roofing materials having a Solar Reflectance Index (SRI) equal to or greater than 29." The magnitude of the project is between $25,000 and $100,000.
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity