Proof Pressure Testing Diesel Fuel Conduit-- SMALL BUSINESS SET ASIDE--

Closed Solicitation Posted

Solicitation number
N61331-22-T-NS06
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
541380 Testing Laboratories and Services
PSC
H247 Equipment And Materials Testing- Pipe, Tubing, Hose, And Fittings
Place of performance
Keyport, Washington 98345, United States

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

AMENDMENT #1 TO EXTEND THE CLOSING DATE TO 8/24/22

Diesel Fuel Conduit Proof Pressure Testing Service--Small Business Set Aside--

Description of Work Requirements as follows:

SCOPE:

The following solicitation is for proof pressure testing to 21,000 PSI of the Diesel Fuel Conduit, PESK-9787.  The scope is for the baseline testing of one OEM Diesel Fuel Conduit (P432959N) produced by Fairbanks Morse, and 32 First Article Diesel Fuel Conduits (PESK-9787) produced at the Naval Undersea Warfare Center, Division Keyport (eg. 33 proof tests total).

TEST DETAILS:

3.1 Test Item Material:  The items to be tested (PESK-9787 and P432959N) will be manufactured from 4340 steel hardened to 33-38 HRC.

3.2  Test Connections:  The pressure interface connection from the GFE Diesel Conduit Pressure Testing Fixture, SA7145592, to the vendor’s test equipment shall be a port that will accommodate a commercial Parker Hannefin High Pressure Fitting, connection type F250C (1/4 HP).

3.3  Proof Pressure Test Medium:  The medium to be used for proof pressure testing shall be Diesel Fuel Calibration Fluid per ISO 4113.

3.4  Test Gauge/Transducer:  The testing gauge/transducer used for measuring the test pressure shall have a full scale range such that the proof test pressure (21,000 psi) falls within 25%-75% of the full scale value for the gauge/transducer.  Gauge/Transducer accuracy shall be +/-.1% of the full-scale value for the gauge/transducer.

3.5  Test Pressure:  The required proof pressure for all units under test shall be 21,000 +/-200 psi.

3.6  Test Temperature:  Ambient temperature during testing shall be from 60°F-80°F

**For Full details see attached Statement of Work**

Email quotes to nicole.stevens3.civ@us.navy.mil on or before the closing date and time

  • The Government will not accept late quotes.
  • The Government will not accept quotes that are partial or incomplete
  • Provide CAGE code and Lead time on your quote.
  • Be able to invoice through Wide Area Workflow (WAWF).
  • If shipping is not included in the price include a line item for shipping.

**Review all Attachments Posted Prior to Submission of Quote**

Update #1 ·

Diesel Fuel Conduit Proof Pressure Testing Service--Small Business Set Aside--

Description of Work Requirements as follows:

SCOPE:

The following solicitation is for proof pressure testing to 21,000 PSI of the Diesel Fuel Conduit, PESK-9787.  The scope is for the baseline testing of one OEM Diesel Fuel Conduit (P432959N) produced by Fairbanks Morse, and 32 First Article Diesel Fuel Conduits (PESK-9787) produced at the Naval Undersea Warfare Center, Division Keyport (eg. 33 proof tests total).

TEST DETAILS:

3.1 Test Item Material:  The items to be tested (PESK-9787 and P432959N) will be manufactured from 4340 steel hardened to 33-38 HRC.

3.2  Test Connections:  The pressure interface connection from the GFE Diesel Conduit Pressure Testing Fixture, SA7145592, to the vendor’s test equipment shall be a port that will accommodate a commercial Parker Hannefin High Pressure Fitting, connection type F250C (1/4 HP).

3.3  Proof Pressure Test Medium:  The medium to be used for proof pressure testing shall be Diesel Fuel Calibration Fluid per ISO 4113.

3.4  Test Gauge/Transducer:  The testing gauge/transducer used for measuring the test pressure shall have a full scale range such that the proof test pressure (21,000 psi) falls within 25%-75% of the full scale value for the gauge/transducer.  Gauge/Transducer accuracy shall be +/-.1% of the full-scale value for the gauge/transducer.

3.5  Test Pressure:  The required proof pressure for all units under test shall be 21,000 +/-200 psi.

3.6  Test Temperature:  Ambient temperature during testing shall be from 60°F-80°F

**For Full details see attached Statement of Work**

Email quotes to nicole.stevens3.civ@us.navy.mil on or before the closing date and time of 12 August 2022, 1200 pm Central Time.

  • The Government will not accept late quotes.
  • The Government will not accept quotes that are partial or incomplete
  • Provide CAGE code and Lead time on your quote.
  • Be able to invoice through Wide Area Workflow (WAWF).
  • If shipping is not included in the price include a line item for shipping.