Proof Pressure Testing Diesel Fuel Conduit-- SMALL BUSINESS SET ASIDE--
Closed Solicitation Posted
- Solicitation number
- N61331-22-T-NS06
- Agency
-
Naval Sea Systems Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 541380 Testing Laboratories and Services
- Place of performance
- Keyport, Washington 98345, United States
Notice details come from SAM.gov. Updated .
Notice text
2 versions
Update #2 · Latest ·
AMENDMENT #1 TO EXTEND THE CLOSING DATE TO 8/24/22
Diesel Fuel Conduit Proof Pressure Testing Service--Small Business Set Aside--
Description of Work Requirements as follows:
SCOPE:
The following solicitation is for proof pressure testing to 21,000 PSI of the Diesel Fuel Conduit, PESK-9787. The scope is for the baseline testing of one OEM Diesel Fuel Conduit (P432959N) produced by Fairbanks Morse, and 32 First Article Diesel Fuel Conduits (PESK-9787) produced at the Naval Undersea Warfare Center, Division Keyport (eg. 33 proof tests total).
TEST DETAILS:
3.1 Test Item Material: The items to be tested (PESK-9787 and P432959N) will be manufactured from 4340 steel hardened to 33-38 HRC.
3.2 Test Connections: The pressure interface connection from the GFE Diesel Conduit Pressure Testing Fixture, SA7145592, to the vendor’s test equipment shall be a port that will accommodate a commercial Parker Hannefin High Pressure Fitting, connection type F250C (1/4 HP).
3.3 Proof Pressure Test Medium: The medium to be used for proof pressure testing shall be Diesel Fuel Calibration Fluid per ISO 4113.
3.4 Test Gauge/Transducer: The testing gauge/transducer used for measuring the test pressure shall have a full scale range such that the proof test pressure (21,000 psi) falls within 25%-75% of the full scale value for the gauge/transducer. Gauge/Transducer accuracy shall be +/-.1% of the full-scale value for the gauge/transducer.
3.5 Test Pressure: The required proof pressure for all units under test shall be 21,000 +/-200 psi.
3.6 Test Temperature: Ambient temperature during testing shall be from 60°F-80°F
**For Full details see attached Statement of Work**
Email quotes to nicole.stevens3.civ@us.navy.mil on or before the closing date and time
- The Government will not accept late quotes.
- The Government will not accept quotes that are partial or incomplete
- Provide CAGE code and Lead time on your quote.
- Be able to invoice through Wide Area Workflow (WAWF).
- If shipping is not included in the price include a line item for shipping.
**Review all Attachments Posted Prior to Submission of Quote**
Update #1 ·
Diesel Fuel Conduit Proof Pressure Testing Service--Small Business Set Aside--
Description of Work Requirements as follows:
SCOPE:
The following solicitation is for proof pressure testing to 21,000 PSI of the Diesel Fuel Conduit, PESK-9787. The scope is for the baseline testing of one OEM Diesel Fuel Conduit (P432959N) produced by Fairbanks Morse, and 32 First Article Diesel Fuel Conduits (PESK-9787) produced at the Naval Undersea Warfare Center, Division Keyport (eg. 33 proof tests total).
TEST DETAILS:
3.1 Test Item Material: The items to be tested (PESK-9787 and P432959N) will be manufactured from 4340 steel hardened to 33-38 HRC.
3.2 Test Connections: The pressure interface connection from the GFE Diesel Conduit Pressure Testing Fixture, SA7145592, to the vendor’s test equipment shall be a port that will accommodate a commercial Parker Hannefin High Pressure Fitting, connection type F250C (1/4 HP).
3.3 Proof Pressure Test Medium: The medium to be used for proof pressure testing shall be Diesel Fuel Calibration Fluid per ISO 4113.
3.4 Test Gauge/Transducer: The testing gauge/transducer used for measuring the test pressure shall have a full scale range such that the proof test pressure (21,000 psi) falls within 25%-75% of the full scale value for the gauge/transducer. Gauge/Transducer accuracy shall be +/-.1% of the full-scale value for the gauge/transducer.
3.5 Test Pressure: The required proof pressure for all units under test shall be 21,000 +/-200 psi.
3.6 Test Temperature: Ambient temperature during testing shall be from 60°F-80°F
**For Full details see attached Statement of Work**
Email quotes to nicole.stevens3.civ@us.navy.mil on or before the closing date and time of 12 August 2022, 1200 pm Central Time.
- The Government will not accept late quotes.
- The Government will not accept quotes that are partial or incomplete
- Provide CAGE code and Lead time on your quote.
- Be able to invoice through Wide Area Workflow (WAWF).
- If shipping is not included in the price include a line item for shipping.