Preventive maintenance for breathing air equipment services
Award Notice Posted
- Solicitation number
- W911RQ16T0004
- Agency
-
ACC Warren
Army Contracting Command, Department of Defense
- Awarded
- to Hoyt Enterprises, Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- W911RQ-16-P-0042 Federal contract award
- NAICS code
- 333912 Air and Gas Compressor Manufacturing
- PSC
- Not on record
- Place of performance
- Red River Army Depot Texarkana, Texas 75507, United States
Notice details come from SAM.gov. Updated .
Notice text
3 versions
Update #3 · Latest ·
Awarded Vendors: HOYT ENTERPRISES, INC. Contract Award Dollar Amount: $91,612.00. Contract Award Date: 2016-03-09.
Update #2 ·
The requirements for service of the Breathing Air Compressor in Fire Station #2 (compressor) and the Self-Contained Breathing Apparatus (SCBA) on Red River Army Depot for one 12 month period. The service contract shall include an option to extend the service for up to an additional four 12 month periods. Option years shall begin after the expiration of the previous contract period to maintain the quarterly testing schedule. The purpose of this service contract is to regularly certify that the air from the compressor meets all applicable breathing air standards, to perform preventive maintenance on the compressor to ensure proper operation and reliable service, and to inspect and certify the SCBA in accordance with all applicable regulations. RRAD shall provide the contractor a list of SCBA..
Update #1 ·
The requirements for service of the Breathing Air Compressor in Fire Station #2 (compressor) and the Self-Contained Breathing Apparatus (SCBA) on Red River Army Depot for one 12 month period. The service contract shall include an option to extend the service for up to an additional four 12 month periods. Option years shall begin after the expiration of the previous contract period to maintain the quarterly testing schedule. The purpose of this service contract is to regularly certify that the air from the compressor meets all applicable breathing air standards, to perform preventive maintenance on the compressor to ensure proper operation and reliable service, and to inspect and certify the SCBA in accordance with all applicable regulations. RRAD shall provide the contractor a list of SCBA.
Files
| File | Type | Posted |
|---|---|---|
| W911RQ-16-T-0004-P0001.pdf | ||
| W911RQ-16-T-0004.pdf |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity