Powerhouse and Dam Pump Room Roof Replacement, Russel Dam, Elberton, Georgia

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
W912HN21S5008
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
Not on record
PSC
Not on record

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers, Savannah District is seeking information from contractors interested in replacing the roofs of the Powerhouse, Visitor Center, and Dam Pump Room buildings at Russel Dam in Elberton, Georgia. The contractor will remove the existing two-ply modified bitumen and built-up roof systems, replacing them with new single-ply ethylene propylene diene monomer roofs including flashings, insulation, walkways, and other accessories to provide watertight roof systems with a minimum R-value of R-30 that drain naturally without standing water. Interested parties are requested to provide information on their company, bonding, and experience in industrial or commercial roof replacement by June 3, 2021 to be considered for the future solicitation of this project.

There is no set-aside designated for this procurement. The NAICS code is 238160 for Roofing Contractors and the PSC code was not provided. No current or incumbent contractors were named. Interested parties are requested to submit details on their business size, including designation as small, HUBZone, 8(a), veteran-owned, woman-owned, or large business. The notice did not include potential award values or timelines for completion of the roof replacement services.

Notice text

This is a Sources Sought/Request for Information only. This is not a Solicitation Announcement, nor is it a Request for Proposal. This request does not obligate the Government in any contract award. The U.S. Army Corps of Engineers, Savannah District is issuing the sources sought synopsis as a means of conducting market research to identify parties having an interest in and
the resources to support the requirement for civil works construction. The result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 238160 – Roofing Contractors.

The contractor will complete the removal and replacement of the entire existing two-ply Granule surfaced modified bitumen roof system and walking pads on all roof areas of the Powerhouse/Visitor Center Building. The contractor will replace the roof with a new 90-mil 1-ply EPDM roof system complete with associated flashings, insulation, sheet metal components and accessories necessary for a watertight roof system. EPDM shall be white in color to reflect solar radiation. New roof shall provide a minimum R value of R-30. New roof system shall drain naturally into existing drains and not hold standing water. Remove existing roof wall and
curb flashings. Remove existing EPDM on all parapet walls. Install new ½” heavy duty cover board on both the horizontal and vertical surfaces of all parapet walls of Powerhouse Roof. New 60-mil white EPDM will be installed over the cover boards with bonding adhesive. Walkboards/Walkpads shall be included and will match existing powerhouse layouts around HVAC units, exhaust fans, upstream and downstream parapet wall, ladder crossovers, and roof access hatch. EPDM walkway pads or equivalent shall be used. Walkboards/walkpads shall also be white in color if available.

The contractor shall remove and replace the entire existing insulated tar and gravel built-up roof systems on concrete deck on dam pump room. Remove existing pump room roof wall and curb flashings. Remove existing roofing of all parapet walls. Install new ½” HD cover board on both the horizontal and vertical surfaces of the parapet walls of Dam Pump Roof area. New 60-mil white EPDM will be installed over the cover boards with bonding adhesive. Replacement with a new 90-mil 1-ply  EPDM  complete  with  associated flashings, insulation, sheet metal components and accessories necessary for a watertight roof system. EPDM shall be white in color to reflect solar radiation. New roof shall provide a minimum R value of R-30. New roof system shall drain naturally into existing drains and not hold standing water. Walkboards/walkpads shall be installed on Dam Pump Roof from the East side of the roof around exhaust fan. White EPDM walkway pads or equivalent shall be used.  Walkboards/walkpads shall also be white in color if available.


A Minimum 20-year, no dollar limit, labor & material warranty from the manufacturer shall be provided. All demolished roofing material shall be removed and properly disposed of by the contractor.

Power plant work hours are 06:00 to 16:30 M-Thurs. Contractor may be allowed to work on roof outside of plant staff work hours if accessing from outside powerhouse with temporary exterior stairs or approved lift. Contractor should work from South Carolina side to the Georgia side. Staging and access will be from the Georgia side, downstream of the Visitor Center.

Safety is in accordance with the latest edition of the EM 385-1-1. A fall protection plan and qualified Site Safety and Health Officers (SSHO) will be required. Airborne irritants and high Volatile Organic Compound (VOC) products will only be used when coordinated with the plant staff to prevent intrusion into the powerhouse HVAC system.

If you are interested in this project and/or your organization has the potential capacity to perform these services, please submit the following to the Point of Contact (POCs) information listed below:
1. Name and Address of your firm
2. Point of Contact (name/phone/email)
3. Company website
4. Data Universal Numbering System (DUNS) number (http://www.dnb.com)
5. Commercial and Government Entity (CAGE) code https://cage.dla/mil
6. Business Size, to include designation as HUBZone, 8(a), Service Disabled Veteran Owned Small Business, Small Disadvantaged Business, Woman-Owned Business, and Large Business. The Government must be able to verify SBA certification of HUBZone, 8(a), and SDB via the System for Award Management (SAM) (https://www.beta.sam.gov).
7. Bonding capability for your firm in terms of single and aggregated bonding.
8. Capability statement addressing the particulars of this effort, with appropriate documentation supporting claims of organizational and staff capability. Please state if you have experience in industrial or commercial roof replacement or construction. If significant subcontracting (self-performance is less than 15%) or teaming is anticipated in order to deliver technical capability

Attachments:  RBR Powerhouse Roof Scope Pic 1

                        RBR Powerhouse Roof Scope Pic 2 

Files

File Type Posted
RBR Powerhouse Roof Scope Pic 2.pdf PDF
RBR Powerhouse Roof Scope Pic 1.pdf PDF

Notice history

Notice Type Posted
Powerhouse and Dam Pump Room Roof Replacement, Russel Dam, Elberton, Georgia Award Award Notice
Powerhouse and Dam Pump Room Roof Replacement, Russel Dam, Elberton, Georgia Latest solicitation Solicitation
Powerhouse and Dam Pump Room Roof Replacement, Russel Dam, Elberton, Georgia Pre-Solicitation
Powerhouse and Dam Pump Room Roof Replacement, Russel Dam, Elberton, Georgia Pre-Solicitation
This notice Original Pre-Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors