Power Conditioner being installed at the Transonic Dynamics Tunnel

Closed Special Notice Posted

Solicitation number
80NSSC25903919Q
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Hampton, Virginia 23681, United States

Notice details come from SAM.gov. Updated .

About this opportunity

NASA's National Spaceflight Support Center (NSSC) has issued a Special Notice for the installation of a Power Conditioner at the Transonic Dynamics Tunnel located at NASA Langley Research Center. The opportunity is structured as a small business set-aside contract for electrical construction services involving complex power system modifications. The Special Notice indicates NASA intends to potentially award the contract directly to Saunders Contracting LLC under Federal Acquisition Regulation (FAR) 13.106-1(b)(1)(i) provisions. The contract falls under the NAICS category 811210 for Electronic and Precision Equipment Repair and Maintenance. The procurement will involve detailed electrical system upgrades in Building 648, Room 111.

Contractors interested in this opportunity must submit their capabilities and qualifications in writing by 4:00 p.m. Central Standard Time on May 26, 2025. The government will evaluate submissions to determine whether to conduct the procurement on a competitive basis, with final discretion remaining with NASA. Eligible contractors must be small businesses capable of performing comprehensive electrical system modifications, including demolishing existing infrastructure, extending conduits and feeder cables, and installing new electrical components. The project requires a 365-day performance period and involves replacing an outdated power conditioning system with a new 55kVA Power Conditioner and two 225A panelboards. Key deliverables will include a detailed proposal, site visit documentation, progress meeting minutes, acceptance testing, as-built drawings, equipment manuals, and a commissioning report. Oral communications are not acceptable, and the NASA Clause 1852.215-84 Ombudsman provision is applicable to this procurement.

Notice text

NASA/NSSC has a requirement for the installation of a Power Conditioner being installed at the Transonic
Dynamics Tunnel. See the attached SOW and capability statement for full details.

Files

File Type Posted
Tab 07 Capability Statement SAM.pdf PDF
Tab 04 SOW.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
Repair and replacement of existing MTS lab Equipment Hampton, Virginia 23681, United States · NAICS 334519 Shared Services Center No set-aside
Pre-Solicitation Notice for a Model Support Replacement of the Unitary Plan Wind Tunnel Moffett Field, California 94035, United States · NAICS 332710 Ames Research Center Total Small Business
NCOM 27-003 FY 27 Trane Chiller Replacement (F2, G2 & G1) Stennis Space Center, Mississippi, United States · NAICS 333415 Shared Services Center No set-aside
Fluke Electronic Equipment NAICS 541519 Shared Services Center No set-aside
Removal, refurbishment, and reinstallation of two (2) 200 HP General Electric (GE) induction motor at the Unitary Plan Wind Tunnel facility United States · NAICS 811310 Shared Services Center Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors