Portable Aerosol Particle Counter
Closed Solicitation Posted
- Solicitation number
- FDA-RFQ-135363
- Agency
-
FDA Office of Acquisition and Grant Services
Food and Drug Administration, Department of Health and Human Services
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 334516 Analytical Laboratory Instrument Manufacturing
- PSC
- 6640 Laboratory Equipment And Supplies
- Place of performance
- Winchester, Massachusetts 01890, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Food and Drug Administration seeks one newly manufactured Portable Aerosol Particle Counter to support regulatory testing, with quotes due August 17, 2026 and delivery required within 60 days of contract award. Award will be made to a GSA Federal Supply Schedules contractor on a firm fixed-price basis, with no small business set-aside.
Place of performance is Winchester, MA. The equipment must measure particles within 0.3 to 25.0 micrometers, operate at a flow rate of at least 1 CFM (28.3 LPM ±5%), and include an isokinetic probe, tripod adapter, minimum 8 feet of tubing, zero count filter, and wireless capability. The unit must feature a touchscreen interface, onboard memory, and USB storage; support Windows 11; comply with ISO 17025:2015, ISO 14644-1:2015, and CFR 21 Part 11; and include a printer and manufacturer warranty of at least one year beginning upon formal government acceptance. The supplier must provide an IQ/OQ validation manual, software with validation manual, and supporting documentation.
All shipping and handling costs are included in the quoted price with FOB Destination delivery. Quotes must be submitted by email to Roosevelt Walker (roosevelt.walker@fda.hhs.gov) and held firm through September 30, 2026. Invoices are submitted electronically through the Department of Treasury's Invoice Processing Platform within Net 30 days of government acceptance. Award will be made to the lowest-priced technically acceptable and responsible offeror. The NAICS code is 334516, Analytical Laboratory Instrument Manufacturing; PSC is 6640, Laboratory Equipment and Supplies.
Notice text
The Food and Drug Administration (FDA) requires a new Portable Aerosol Particle Counter to support regulatory testing.
Files
| File | Type | Posted |
|---|---|---|
| RFQ_135363_Portable Aerosol Particle Counter.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Air sampler | Naval Supply Systems Command | Total Small Business | |
| Low Background Smear Counter | Office of Science | No set-aside | |
| Purifier unit, air | Construction and Equipment | HUBZone |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity