PM Medical Equipment Cooling System
Awarded Award Notice Posted
- Solicitation number
- 36C24418Q0082
- Agency
- Veterans Integrated Service Network 4 Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to Site Support Services, Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- 36C24418C0081 Federal contract award
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- Not on record
Notice details come from SAM.gov. Updated .
Notice text
Added: Nov 02, 2017 9:43 am
Sources Sought Note:
This notice is published in accordance with Federal Acquisition Part (FAR) Part 10, Market Research and FAR Part 15, Exchanges with Industry before Receipt of Proposal. This notice serves as a Sources Sought in support of market research and/or planning purposes only and does not constitute a solicitation. This notice is not a confirmation that the Government will contract for the items or services contained in the sources sought, nor is any commitment on the part of the Government to award a contract implied. This notice does NOT constitute an Invitation to Bid, a Request for Proposal, or a Request for Quote. The Government shall not pay and/or reimburse respondents and/or associates for any costs incurred to submit the requested information. All information received in response to this sources sought that is marked Proprietary will be handled accordingly. In accordance with FAR 15.201(c), response to this sources sought is not offers and cannot be accepted by the Government to form a binding contract.
The purpose of this is to seek capable and responsible sources interested in performing this service. Responses will assist the Government with developing its acquisition strategy to include socio-economic set-asides. If you believe there are ambiguities in the draft SOW, please identify them. Note that the Government will not answer questions about this requirement at this time. Please answer the questions below, send your brief capability narrative and draft SOW feedback, if ambiguities exist, to me at Donald.Butler3@va.gov not later than 1100 AM E.S.T. 11/09/17.Â
If you are interested, please e-mail:
Company Name.
Person of Contact (including telephone number and email address).
Socio-economic status (SDVOSB, VOSB, Woman-Owned, Other etc.).
Do you currently hold a government contract?
Contract Number?
Type of contract?
With whom (GSA, SEWP, etc )?
If GSA what Schedule and SIN?
Can your company provide the service listed at the Philadelphia PA VAMC locations?
What NAIC and PSC code do you use for this service?
How do you invoice for this service including rates?
What Certifications, State and Federal, if any must you have to perform this service?
Please submit any other information you may feel important or relevant to Donald Butler at donald.butler3@va.gov by 11:00 AM EST 11/09/2017.
CORPORAL MICHAEL J. CRESCENZ
DEPARTMENT OF VETERANS AFFAIRS MEDICAL CENTER
PHILADELPHIA, PA 19104
Medical Equipment cooling system PM
Work Statement
Provide Labor and material necessary for :
Conducting four (4) preventive maintenance inspections on the equipment listed below quarterly.
Coordinate work and visits with A/C foreman.
Submit to the A/C foreman detailed service reports on equipment inspected and maintained to establish individual unit case history of PM.
Provide Emergency fast response 2-hours emergency service for VA equipment.
Provide Service work, emergency service, repairs and parts other than the preventive main tenance inspections and included maintenance materials within two hours from VA request for service.
The contractor shall provide the service on a time and shall possess the material /parts required for repair.
PM requirements:
The contractor shall respond no later than 24-hours after none emergency service calls.
Two (2) Hour Emergency Service Response on computer room, and medical equipment Environmental control units.
The contractor shall possess 24/7 emergency call service.
The contractor shall possess Liebert united certified technicians.
The contractor shall possess parts and materials necessary to service and maintain the PVAMC equipment.
The contractor shall conduct Preventive maintenance inspections during normal working hours
Quarterly PM to include
Inspect air filters and change as needed.
Inspect fan belts and change or adjust as needed.
Lubricate fan shafts & motor bearings at required intervals per manufacturer s specifications.
Inspect humidifier
Quartz lamps replace if necessary
Clean pan if necessary
Inspect water level and adjust as required
Inspect water flow and adjust as needed
Change humidifier water filter as applicable
Monitor oil levels and adjust level as needed.
Monitor and test all coolant (water, glycol, etc.) levels
Monitor air intake and return temperatures
Inspect and repair as needed, all compressors
Inspect gas exchanger and adjust as required
Check and adjust, as applicable, hot gas bypass.
Check and adjust as required, all unit controllers
Inspect and confirm proper compressor operation.
Temperatures
Pressures (as needed)
Amperage (as needed)
D. Voltage (Power)
E. Voltage (Control)
F. Sound Levels and for unusual noise
Inspect refrigerant sight glass.
Low charge
Moisture indication
Leak check and charge (as applicable to selected plan) if required by inspections 7 and 8 listed above.
Inspect evaporator coil and clean if necessary.
Inspect evaporator fans and motor for proper operation.
Check supply and return air temperatures.
Check condenser water leaving and entering temperatures (as applicable).
Check all control set points and adjust as required.
Inspect all electrical controls for:
Visual damage
Chattering
Loose connections
Pitting & heat damage
Tighten all electrical connections (as needed).
Check condensate line, drain pan, pump, drain and coils. Clean or replace these items as needed. Tighten bolts and other parts as appropriate, if leak is detected.
Clean condensate pans and pump basins as required by visual inspection.
Clean condensate drains as needed.
Inspect air-cooled condenser/drycooler fans.
Inspect condenser/drycooler coils and clean as needed (not to exceed once per year)
Inspect pump packages and expansion tanks (as applicable).
Change system sequence switches to equalize run times (as applicable).
Check and adjust, as applicable, hot gas bypass.
Test glycol freeze protection & clarity (as applicable once per year).
Inspect water/glycol cooled condenser end bells for leaks, re-torque bolts once per year (as applicable).
Inspect water regulating valve bellows for leaks, correct as needed (as applicable).
Leave a copy of detailed service reports for all maintenance activities with A/C foreman and discuss any necessary follow-ups or recommendations.
PVAMC EQUIPMENT LIST
LOCATION
MAKE
MODEL#
SERIAL#
DESC.
AREA SERVICING
Room 4B102
Filtrine
SMS-500G-70AR-RED
3279-1`/08
Chiller
CT Gantry
4th Floor Roof
Witt
WCS020VG
E08E42869601001
Condenser
CT Gantry
Room 4B102
Filtrine
PCP-2000G-230AR-RED-HX
6718-1/09
Chiller
MRI
4th Floor Roof
Witt
WCS016VG
E09H47902701002
Condenser
MRI
Room 4B102
Filtrine
PCP-2000S-230AR-RED-HX
6718-2/09
Chiller
MRI
4th Floor Roof
Witt
WCS016VG
E09H47902701001
Condenser
MRI
Room 4B102
Filtrine
PCP-2000S-230AR-RED-HX
6718-3/09
Chiller
MRI
4th Floor Roof
Witt
WCS016VG
E09H47902701003
Condenser
MRI
Room 4B102
Liebert
PS036A-AB2
845297
Chiller
Serves York AHU
Room 4B102
Liebert
MMD24E-PHEBO
0552N119589
Mini Mate
Room 3A192A
Room 4B102
Liebert
PFH027A-PH3
0552N119446
Condenser
N/A
Room 4B102
Liebert
CT327A-AS7432
927432-001
Chiller
MRI
4th Floor Roof
Liebert
DCDS205-A
0729C01631
Condenser
MRI
4th Floor Roof
Liebert
DCDS205-A
0729C01635
Condenser
MRI
4th Floor Roof
Liebert
DCDS205-A
0729C01641
Condenser
MRI
Room 4B102
Liebert
MMD96K7AHEHO
0932N187835
Mini Mate
Closet inside of
Room 4B102
Liebert
MCD96W3AH7
0932N187841
Condenser
Room 3A177
4th Floor Roof
Liebert
DD0310AS1549
0935C22959
Drycooler
N/A
Room 4B102
Liebert
MMD36K7AHEBO
0932N187988
Mini Mate
Room 3A177
Room 4B102
Liebert
MCD38W3AH7
0933N188045
Condenser
N/A
4th Floor Roof
Liebert
DD0310AS1549
0935C22959
Drycooler
N/A
Room 3A151N
Liebert
DME020E-PH3
0714N145867
Data Mate
Room 3A151N
Room 4B102
Liebert
PFH020A-PL3
0713N145510
Condenser
Room 3A151N
Room 3A151
Liebert
DME020E-PH3
0936N188978
Data Mate
Room 3A151
Room 4B102
Liebert
PFH020A-PL7
0936N188946
Condenser
N/A
Room 4B102
Liebert
WLC00W-K00
45620
RCM4
N/A
Mech. Rm. B2B106
Liebert
MMD36E-AHEBD598
0904N179763
Mini Mate
CT Simulator Rm.
Mech. Rm. B2B106
Liebert
MCD36ALAH3S2061
0904N179755
Condenser
CT Gantry
N/A
Liebert
DS077KSA0EI950S
C12K8H0017
CRAC
N/A
N/A
Liebert
DS077KSA0EI950S
C12K8H0018
CRAC
N/A
N/A
Liebert
DS077KSA0EI950S
C12K8H0019
CRAC
N/A
N/A
Liebert
DS077KSA0EI950S
C12K8H0020
CRAC
N/A
N/A
Liebert
DDNT700A
C12DT20411
Dry Cooler
N/A
N/A
Liebert
DDNT700A
C12DT20413
Dry Cooler
N/A
N/A
Liebert
N/A
N/A
Pump Package
N/A
N/A
Liebert
N/A
N/A
Pump Package
N/A
N/A
Carrier
39LB06AABFAMNB9
4604F69253
AHU
N/A
N/A
Carrier
39LA03AABBAMJB9
4604F69263
AHU
N/A
N/A
Carrier
39LD03AABTBNJA9
4604F69264
AHU
N/A
N/A
Carrier
38ARZ008---501CA
4204G40064
Condenser
N/A
N/A
Trane
TTA073D300AA
10112K8RAD
Condenser
N/A
N/A
Carrier
24ABS360A500
2108E01567
Condenser
N/A
Notice history
| Notice | Type | Posted |
|---|---|---|
| PM Medical Equipment Cooling System | Award Notice | |
| PM Medical Equipment Cooling System | Award Notice |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity