Piping installation in the Wind Tunnel Laboratory

Closed Pre-Solicitation Posted

Solicitation number
W15QKN25RA051
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Wind Tunnel Facility Fcdd-ACM-Faattn: TBD Picatinny Arsenal, NJ 07806 07849

Notice details come from SAM.gov. Updated .

About this opportunity

The United States Army Contracting Command - New Jersey is seeking a sole-source procurement for piping installation services in the Wind Tunnel Laboratory at Picatinny Arsenal. The contract, identified as W15QKN-25-R-A039, is specifically targeted to Comairco Equipment, Inc. of Cheektowaga, NY, for upgrading the laboratory's piping infrastructure. The procurement will involve installing new piping configurations for air compressors, storage tanks, safety relief valves, electronic drains, desiccant air dryers, oil water separators, and flanges to support hypersonic research and testing capabilities. Potential offerors should direct any questions in writing to Howard Kane, Zach Smith, or Gloria Thoguluva via their .civ@army.mil email addresses before the May 27, 2025 deadline. The contract will be processed under Federal Acquisition Regulation (FAR) 13.501(a)(1)(ii) for simplified acquisition of commercial items.

The pre-solicitation notice indicates no specific set-aside designations for this procurement. Comairco Equipment, Inc. has been selected as the sole source contractor due to their unique qualifications as the original equipment manufacturer with 30 years of experience in Wind Tunnel activities at Picatinny Arsenal. While the exact contract value is not explicitly stated, the procurement is classified under NAICS Code 238220 for Plumbing, Heating, and Air-Conditioning Contractors. Market research conducted through a sources sought notice confirmed Comairco as the only qualified vendor capable of performing the work without risking existing equipment warranties or potential system damage. The unclassified effort will be performed directly at Picatinny Arsenal, with performance details and specific timelines to be further specified in the full solicitation documents.

Notice text

2 versions

Update #2 · Latest ·

Pre-solicitation Synopsis for the piping installation in the Wind Tunnel Laboratory W15QKN-25-R-A039The United States Army Contracting Command ? New Jersey on behalf of the United States Army Combat Capabilities Development Command ? Armament Center. The Justification and Approval is attached.

Update #1 ·

Pre-solicitation Synopsis for the piping installation in the Wind Tunnel Laboratory W15QKN-25-R-A039The United States Army Contracting Command ? New Jersey on behalf of the United States Army Combat Capabilities Development Command ? Armament Center.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Repair / Replacement of Mission and Industrial HVAC and Refrigeration Systems 07806 · NAICS 238220 ACC Picatinny No set-aside
Cryogenic Regulator Manifold Installation Place of Performance:DoDAAC: W911PTCountryCode: USAW6QK Acc Wvaacc Watervliet Arsenal, 1 Buffington St Watervliet, NY 12189UNITED States 12189 · NAICS 811310 ACC Warren No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors