PES Transformer #7 Root Cause Analysis (RCA)

Cancelled Solicitation Posted

Solicitation number
FA910123RB010
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
541330 Engineering Services
PSC
B513 Special Studies/Analysis- Feasibility (Non-Construction)

Notice details come from SAM.gov. Updated .

Notice text

4 versions

Update #4 · Latest ·

The purpose of the subject amendment is to extend the RFP response time from 3:00 PM CST on 22 Feb 23 to 1:00 PM CST on 28 Feb 23.

The purpose of this solicitation is for the Government to obtain a Root Cause Analysis report that details the root cause for failure of a 161- kV, 192.258 MVA for 5 minutes, Brand-name Tamini transformer, (with 33-position on-load tap changer) Serial Number 66826, in accordance with Attachment 1 – Statement of Work (SOW). There are four tasks associated with the required service: 1. Develop and deliver a Fault Data Report; 2. Develop and deliver a Preliminary On-site Inspection and Testing Report; 3. Conduct an Internal Inspection; and 4. Develop and deliver an Inspection, Analysis and Comprehensive Report. 

Update #3 ·

The purpose of the subject amendment is to extend the RFP response time from 1:00 PM CST on 21 Feb 23 to 3:00 PM CST on 22 Feb 23.

The purpose of this solicitation is for the Government to obtain a Root Cause Analysis report that details the root cause for failure of a 161- kV, 192.258 MVA for 5 minutes, Brand-name Tamini transformer, (with 33-position on-load tap changer) Serial Number 66826, in accordance with Attachment 1 – Statement of Work (SOW). There are four tasks associated with the required service: 1. Develop and deliver a Fault Data Report; 2. Develop and deliver a Preliminary On-site Inspection and Testing Report; 3. Conduct an Internal Inspection; and 4. Develop and deliver an Inspection, Analysis and Comprehensive Report. The anticipated Period of Performance (PoP) is 01 March 2023 – 30 April 2023.

Update #2 ·

The purpose of the subject amendment is to provide the revised RFP Attachment 2 - Pricing Worksheet, in which the following CLIN was added: CLIN x005 "Supplies - Temporary Shelter IAW Proposed Temporary Shelter Plan". Please reference and utilize this version of the Pricing Worksheet going forward.

The purpose of this solicitation is for the Government to obtain a Root Cause Analysis report that details the root cause for failure of a 161- kV, 192.258 MVA for 5 minutes, Brand-name Tamini transformer, (with 33-position on-load tap changer) Serial Number 66826, in accordance with Attachment 1 – Statement of Work (SOW). There are four tasks associated with the required service: 1. Develop and deliver a Fault Data Report; 2. Develop and deliver a Preliminary On-site Inspection and Testing Report; 3. Conduct an Internal Inspection; and 4. Develop and deliver an Inspection, Analysis and Comprehensive Report. The anticipated Period of Performance (PoP) is 01 March 2023 – 30 April 2023.

Update #1 ·

The purpose of this solicitation is for the Government to obtain a Root Cause Analysis report that details the root cause for failure of a 161- kV, 192.258 MVA for 5 minutes, Brand-name Tamini transformer, (with 33-position on-load tap changer) Serial Number 66826, in accordance with Attachment 1 – Statement of Work (SOW). There are four tasks associated with the required service: 1. Develop and deliver a Fault Data Report; 2. Develop and deliver a Preliminary On-site Inspection and Testing Report; 3. Conduct an Internal Inspection; and 4. Develop and deliver an Inspection, Analysis and Comprehensive Report. The anticipated Period of Performance (PoP) is 01 March 2023 – 30 April 2023.