The U.S. Army Corps of Engineers, Mobile District is seeking information from manufacturers for an alternate brand of spray-on rubber membrane coating and topcoat to replace the existing roofing system on Building 103 at the Michoud Assembly Facility located at Stennis Space Center, Alabama. The existing modified bitumen roof is nearing the end of its useful life. The new coating must be 100% waterproof, withstand standing water indefinitely, and meet specific physical characteristics and performance standards. Responses are due by November 25, 2022 and shall include product data, statements of compliance, warranty information, and references for similar projects.
There is no set-aside designated for this potential procurement. The primary NAICS code is 238160 and PSC code is R499. The incumbent product is Triton Incorporated Trito-flex 2k spray-on rubber membrane coating and topcoat. The Government intends to specify this as a brand name but is seeking alternate manufacturers to consider. No budget or value information was provided, but the scope involves replacement of an existing roofing system.
Notice text
2 versions
Update #2 · Latest ·
The U.S. Army Corps of Engineers, Mobile District (SAM) intends to place a brand name specification into solicitation W9127823R0003 in accordance with FAR 6.302. Interested persons may identify their capability to respond to the requirement. This notice is not a request for competitive proposals; however, all information received by the date indicated in this notice will be considered by the Government. A determination by the Government not to include this proposed brand name specification based upon responses to this notice is solely within the discretion of the Government. The U.S. Army Corps of Engineers, Directorate of Contracting, is conducting a market survey to identify alternate sources for Triton Incorporated Trito-flex 2k spray-on rubber membrane coating and topcoat to be applied on a modified bitumen roofing system.
The U.S. Army Corps of Engineers, Mobile District, anticipates a future procurement for the FY-23 Building 103 Roof Replacement project located at Michoud Assembly Facility (MAF) New Orleans, LA. The existing Building 103 modified bitumen roofing system was designed and installed in 2001. The existing system is a GAF Styrene-Butadiene-Styrene modified bitumen roof on tapered insulation and is nearing the end of its useable lifespan. Repairs on the roofing system for minor leaks, tornado damage, and punctures have been completed.
During various assessments it has been noted the roof must endure standing water for extended periods of time. The required solution must be 100% waterproof and not degrade in standing water. Any equal product must be an instant setting spray applied membrane that is rated to be waterproof and resist ultraviolet degradation while having been tested to adhere with the modified bitumen roofing system. An equal product should also meet the following physical characteristics:
- Roof system shall be UL Class A fire resistance rated
- Roof coating system shall be capable of withstanding indefinite periods of exposure to ponding water, without damaging the fluid-applied material or voiding the required manufacturer’s warranty.
- Coating must be instant setting and able to withstand exposure to atmospheric moisture immediately following application.
- Due to the location the coating must be able to withstand exposure to acids and salts.
- Material must provide severe hail resistance, when tested in accordance with ASTM 4470.
- Coating must have third-party test data showing FM 4474 wind uplift testing with a minimum of FM 1-150 rating, when tested over a modified bitumen membrane substrate.
- Material shall be considered to be vapor impermeable and measure 0.1 perms or less when tested in accordance with ASTM E96/E96M
This request is not a request to be placed on a solicitation mailing list. It is for information only and is not a request for proposal (RFP) or announcement of a solicitation. The purpose of this notice is to understand the market for alternative suppliers of roof membrane replacement systems meeting the requirements above. It is the Government’s intent to specify the Triton Incorporated Trito-flex 2k spray-on rubber membrane coating and topcoat Brand Name for use in the project solicitation described above. Firms shall provide:
- Manufacturer's name and Unique Entity Identifier (UEI) if applicable
- Product data and written statement of compliance with stated requirements. Examples may be Factory Mutual (FM) uplift testing for application of your product to a modified bitumen roofing system hybrid roof system verifying the adherence properties. In addition, the patch and repair process for making modifications or repairs to roof system.
- Previous joint letters of warranty for similar applications providing a 25-year (or greater) manufacturer’s No Dollar Limit (NDL) warranty.
- The written statement of compliance shall include necessary backup design information and supporting documentation. A list of projects in which the spray on membrane has met similar requirements for similar applications shall be provided. The list shall include the exact location of project(s) and a point of contact with phone numbers. The Government will not pay for any material provided in response to this notice nor return the data provided.
Responses should be sent to eric.j.hurtado@usace.army.mil and jennifer.h.suit@usace.army.mil no later than stated response time. No other forms of transmission are requested or will be accepted.
Update #1 ·
The U.S. Army Corps of Engineers, Mobile District (SAM) intends to place a brand name specification into solicitation W9127823R0003 in accordance with FAR 6.302. Interested persons may identify their capability to respond to the requirement. This notice is not a request for competitive proposals; however, all information received by the date indicated in this notice will be considered by the Government. A determination by the Government not to include this proposed brand name specification based upon responses to this notice is solely within the discretion of the Government. The U.S. Army Corps of Engineers, Directorate of Contracting, is conducting a market survey to identify alternate sources for Triton Incorporated Trito-flex 2k spray-on rubber membrane coating and topcoat to be applied on a modified bitumen roofing system.
The U.S. Army Corps of Engineers, Mobile District, anticipates a future procurement for the FY-23 Michoud Assembly Facility (MAF) Building 103 Roof Replacement project located at Stennis Space Center (SSC), AL. The existing Building 103 modified bitumen roofing system was designed and installed in 2001. The existing system is a GAF Styrene-Butadiene-Styrene modified bitumen roof on tapered insulation and is nearing the end of its useable lifespan. Repairs on the roofing system for minor leaks, tornado damage, and punctures have been completed.
During various assessments it has been noted the roof must endure standing water for extended periods of time. The required solution must be 100% waterproof and not degrade in standing water. Any equal product must be an instant setting spray applied membrane that is rated to be waterproof and resist ultraviolet degradation while having been tested to adhere with the modified bitumen roofing system. An equal product should also meet the following physical characteristics:
- 1,200% elongation
- Greater than 600 psi tensile strength (aged result)
- Class A Fire Rating
- Impermeable – withstands ponding water indefinitely
- Zero VOCs, Water-based and odor free
- Instantly rain resistant
- Chemical resistant to acids and salts
- Provides “severe hail resistance” (ASTM 4470)
- Able up to reach 990 psf uplift resistance (actual uplift is dependent on substrate that product is applied to)
- Water permeance 0.1 perms
This request is not a request to be placed on a solicitation mailing list. It is for information only and is not a request for proposal (RFP) or announcement of a solicitation. The purpose of this notice is to understand the market for alternative suppliers of roof membrane replacement systems meeting the requirements above. It is the Government’s intent to specify the Triton Incorporated Trito-flex 2k spray-on rubber membrane coating and topcoat Brand Name for use in the project solicitation described above. Firms shall provide:
- Manufacturer's name and Unique Entity Identifier (UEI) if applicable
- Product data and written statement of compliance with stated requirements. Examples may be Factory Mutual (FM) uplift testing for application of your product to a modified bitumen roofing system hybrid roof system verifying the adherence properties. In addition, the patch and repair process for making modifications or repairs to roof system.
- Previous joint letters of warranty for similar applications providing a 25-year (or greater) manufacturer’s No Dollar Limit (NDL) warranty.
- The written statement of compliance shall include necessary backup design information and supporting documentation. A list of projects in which the spray on membrane has met similar requirements for similar applications shall be provided. The list shall include the exact location of project(s) and a point of contact with phone numbers. The Government will not pay for any material provided in response to this notice nor return the data provided.
Responses should be sent to eric.j.hurtado@usace.army.mil and jennifer.h.suit@usace.army.mil no later than stated response time. No other forms of transmission are requested or will be accepted.
Notice history
| Notice | Type | Posted |
|---|---|---|
| NASA Michoud Assembly Facility (MAF) Building 103 Roof Replacement | Award Notice | |
| NASA Michoud Assembly Facility (MAF) Building 103 Roof Replacement | Solicitation | |
| NASA Michoud Assembly Facility Building 103 Roof Replacement, NASA Michoud, Louisiana (Orleans Parish) | Pre-Solicitation | |
| Sources Sought for NASA Michoud Assembly Facility Building, New Orleans, LA | Pre-Solicitation | |
| Notice of Potential Use of Project Labor Agreements (PLA) for NASA Michoud Assembly Facility Building, New Orleans, LA | Special Notice | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| N0017327Q5317- Roof Membrane Replacement and Waterproofing | Office of Naval Research | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity