Notice of Intent to Sole Source - Remote Monitoring Units - Cathodic Protection

Closed Special Notice Posted

Solicitation number
FA8903-24-R-0006
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
United States

Notice details come from SAM.gov. Updated .

About this opportunity

This Special Notice from the Department of the Air Force Materiel Command Installation and Mission Support Center Installation Contracting Agency (Air Force Installation Contracting Agency) announces the intent to solicit a sole source requirement for Prepaid Cellular/Satellite Data Services for Remote Monitoring Units (RMUs) installed on Cathodic Protection (CP) systems at U.S. Air Force Petroleum Oil Lubricants (POL) sites worldwide. The contract will cover services for 381 RMUs installed at multiple Air Force locations, with an estimated value of $163,000.

The purpose of this sole source requirement is to provide remote monitoring capabilities for the Air Force's CP systems that protect fuel tanks and pipelines from corrosion, as mandated by Unified Facilities Criteria (UFC) 3-570-01 and 3-570-06. ELECSYS Corporation, a commercial provider of RMU solutions, has been identified as the sole source for the required hardware, cellular/satellite communication services, and web-based data monitoring and reporting functionality as a bundled commercial service. The upcoming solicitation, number FA8903-24-R-0006, will be open only to ELECSYS, and no other sources will be considered.

Notice text

This is notice of intent to solicit to a sole source requirement for which justification has been approved. A sources sought was previously posted at FA8903-24-SS-0300

REQUIREMENT
Provide Prepaid Cellular/Satellite Data Services for Rectifier Remote Monitoring Unit (RMUs) Installed at US Air Force Petroleum Oil Lubricants (POL) Sites on Cathodic Protection (CP) Systems Protecting Fuel Tanks and Pipelines from Corrosion.

Number of units: 381

CODES:
• UFC 3-570-01, CP, 28 November 2016, Change 1, 14 January 2019, Par 4-5.1
• UFC 3-570-06, Operation and Maintenance: CP Systems, para. 4-6.1, 15 July 2019
Remote monitoring can be installed to instantly identify readings that are below or above set points. These remote monitoring systems can monitor rectifier AC input voltage, DC output voltage and current, structure potentials, and many other things such as structure bonds, resistance bonds, test station potentials, and galvanic anode currents. Immediate notification of these problems can greatly accelerate the time required to repair the cause of the alarm. These systems can accelerate the data collection and recordkeeping functions, as well as provide much needed data for effective troubleshooting.

SYNOPSIS:
ELECSYS is a commercial provider of Remote Monitoring Units (RMU) to Major Commercial Customers in the Oil, Gas, Water, and Electrical sectors. Figure 1 shows a typical Air Force CP fuel pipeline protection rectifier being monitored by an ELECSYS Watchdog RMU that uses commercial cellular and satellite communications to collect data and send to the ELECSYS server. The ELECSYS Connect application (Figure 2 Close up of Figure 1) provides the data collection, transfer, storage, analysis of data collected.
The “ELECSYS Connect” provides a Web-based Remote Monitoring and Analysis Application for data collection (through cellular and satellite communication networks) and Web-based analysis of data. The basic capabilities of ELECSY Connect (Appendix A) are:
• Access & Analyze Remote Monitor Data (through ELECSYS RMUs)
• Configure Alarms and Reporting Schedule of Collected Data
• Access through any Web-Enabled Device (Controlled Access by login and/or limited access to RMUs, user selection)
• File and Data Transfer Capabilities
• Graphical and Tabular Data Display Options
• GPS function for Pinpoint Location of RMU

The ELECYS Corporation provides Watchdog Web and Data Security (Appendix B). The “best practices” ELECSYS Corporation employs to assure data security and availability for customers are:
• Authentication and Authorization
• Backups
• Configuration Management
• Firewall/Router Security
• Cryptography
• Data Transmission
• Data Validation
• Error Handling
• File Uploads
• Session Management
• Physical Security
The ELECSYS services listed above are available when the ELECSYS Monthly Fee for each RMU is paid and fee covers both the cellular/satellite communication carrier charges and the ELECSYS server services described above. No additional hardware is required. This contract addresses the monthly fee for each RMU for an entire year of ELECSYS RMU commercial services.

Files

File Type Posted
RMU_single_source_justification_CO_signed.pdf PDF

Notice history

Notice Type Posted
This notice Latest special notice Special Notice
Remote Monitoring Units - Cathodic Protection Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Notice of Intent to Sole Source: Commercial Industrial and Liquid Gases and Cylinder Maintenance Pennsylvania 18466, United States · NAICS 325120 Department of the Army No set-aside
3.45 GHz Engineering Support for Enduring Coordination (3-ESEC) Notice of Intent to Sole Source Fort George G Meade, Maryland 20755, United States · NAICS 541511 Defense Information Systems Agency No set-aside
FY27 - Notice of Intent to Sole Source - Advantor Alarm System Holloman Air Force Base, New Mexico 88330, United States · NAICS 561621 Air Combat Command No set-aside
Notice of Intent to Sole Source - MNA Monitoring - Formerly Used Defense Sites (FUDS) – Nike CD-78 Launch Area, Oxford, OH. Oxford, Ohio, United States ENDIST Louisville No set-aside
Intent to Award Sole Source: Patran Software Wright Patterson AFB, Ohio 45433, United States · NAICS 513210 Air Force Research Laboratory No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors