Modify Building 917 Simulator Area and Vault to ICD 705 Standards

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
W912L120B6002
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Jbsa Lackland TX 78236 USA

Notice details come from SAM.gov. Updated .

About this opportunity

This notice provides advance information for an upcoming Invitation for Bid from the USPFO Texas to renovate the simulator area and operations vault in Building 917 to meet ICD 705 standards. The contractor will provide all labor, equipment, and materials to complete the 7,100 SF renovation across 17 rooms, connecting the two secure areas and upgrading security and building systems. The contract will be a firm-fixed price, 300-day contract awarded to a small business. The solicitation will be posted on SAM.gov with questions due by August 4, 2020.

The requirement is set aside 100% for small businesses under NAICS 238290, Construction of Foundation and Structure, with a size standard of $16.5M. The project magnitude is estimated between $1-5M. The pre-solicitation is for information purposes only and no contract will be awarded from this notice. All potential contractors must register in SAM.gov to be considered for award.

Notice text

The USPFO for Texas intends to issue an Invitation for Bid to award a single firm-fixed price contract for services, non-personal, to provide all plant, labor, transportation, materials, tools, equipment, appliances and supervision necessary for the construction of the renovation of the simulator area and operations vault space in building 917 to meet the standard of the Intelligence Community Directive (ICD) 705, version 1.3 in accordance with applicable codes and references, project specifications, drawings, and basis of design. The current 3,500 sf Simulator Area includes rooms 173 to 179 was built in 1983 and the current 3,600 sf Operations Vault Area includes rooms 103 to 117 and 157, was built in 2003. The main door entry to the Simulator Area is on the west-exterior side and there is currently no pathway between the Simulator Area and Operations Vault. Room 179 is used to house the F-16 Weapons System Trainers and contains a fire riser and power panels on the east exterior wall. Two alarm pads exist; a K99 system is protecting rooms 175-178, and a K91 alarm is protecting room 179. The contractor shall provide all necessary labor, supervision, equipment, supplies, and materialsto complete this project. This project will meet USGBC LEED Silver Certifiable level of construction.
The contract duration is 300 days after NTP. This project is set aside 100% for Small Business. The North American Industry Classification (NAICS) Code is 238290, with a size standard of $16,500,000.00. The magnitude is between $1,000,000 and $5,000,000.
This is not a request for proposal. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. This is not a solicitation announcement for proposals and no contract will be awarded from this synopsis. Reimbursement will not be made for any costs associated with providing information in response to this announcement and any follow-up information requests.
The award is contemplated as a 100% small business set aside. The NAICS code is 238290 with the size standard being $15M. All potential contractors must be registered in beta.sam.gov to be considered for award. Not being registered in the www.beta.sam.gov system will make your firm ineligible for consideration of award. Paper solicitations will not be available and the solicitation once posted can be found on the internet at the website 
(http://www.beta.sam.gov/). All documents related to this requirement will be posted on the Federal Business Opportunities Website. For all questions and concerns in regards to this please contact upcoming requirement please email MSgt Mardela Scott at mardela.scott.mil@mail.mil or via phone at 210- 925-7550.

Notice history

Notice Type Posted
Modify building 917 Simulator Area and Vault to ICD 705 Standards Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Design-Build Maintenance and Repair Army Reserve (MRAR) of Equipment Concentration Site (ECS), B-56767, at North Fort Hood, TX Bldg. 56767 Equipment Concentration Site (ECS) #6428th St. and Park Ave.North Fort Hood, TX Gatesville, Texas 76528, United States · NAICS 236220 ENDIST Louisville Total Small Business
Instrument Landing Structure (ILS) Fort Polk, Louisiana, United States · NAICS 238910 ENDIST Fort Worth Total Small Business
Solicitation: Construct Combat Rescue Helicopter Flight Simulator Facility at Moffett ANGB Moffett Angb, Santa Clara County, California Moffett Field, California 94035, United States · NAICS 236220 California National Guard Total Small Business
Sources Sought - Construction Repair Building 6413 Secure Space (511669 & 519580) Barksdale AFB Barksdale AFB, Louisiana 71110, United States · NAICS 236220 ENDIST Fort Worth No set-aside
Sources Sought- Sources Sought & Other Transaction Authority (OTA) Construction for Non-Destructive Testing Facility, Red River Army Depot, Texas Texas 75570, United States · NAICS 236220 ENDIST Fort Worth No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity