McNary Dam Turbine Draft Tube Slot Filler
Closed Pre-Solicitation Posted
- Solicitation number
- W912EF25RSS07
- Agency
-
ENDIST Walla Walla
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 332312 Fabricated Structural Metal Manufacturing
- Place of performance
- Umatilla, Oregon, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The US Army Corps of Engineers, Walla Walla District is seeking sources to fabricate and deliver 12 structural steel turbine draft tube slot fillers for the McNary Dam project. The procurement involves manufacturing 6 sets of slot fillers, with each set containing a north and south draft tube component, measuring approximately 35 feet wide, 20 feet tall, and 3 feet deep. Key contract requirements include AISC (American Institute of Steel Construction) Quality Certification for the fabricating plant, with specific certifications such as HYD: Certified Metal Hydraulic Fabricator, and demonstrated experience completing two similar projects within the past ten years. Potential contractors must have the capability to fabricate structures weighing at least 15 tons, with member thicknesses of 1/2-inch or greater, and meet precise dimensional tolerances. The sources-sought announcement is open from January 7, 2025, to January 22, 2025, with interested firms required to submit detailed information about their technical experience, project references, business size, bonding capacity, and intent to bid.
The contract is not set aside for any specific small business designation, and the North American Industry Classification System (NAICS) code is 332312 with a small business size standard of 500 employees. Each slot filler will weigh approximately 35,000 pounds, primarily composed of steel, and will be fabricated using ASTM A572 grade 50 structural steel plates and ASTM A1085 Hollow Structural Sections. The painting requirements include an Epoxy Polysiloxane paint system for the first set and a 5-E-Z vinyl paint for the remaining five sets, with the painting contractor required to hold an SSPC QP 3 certification from the Association for Materials Protection and Performance. A test slot filler set will be delivered first, installed, and inspected, with potential design modifications made before the contractor proceeds with fabricating and delivering the remaining five sets. The project involves precise manufacturing specifications, including specific paint systems, steel grades, and dimensional requirements, suggesting a complex and technically demanding procurement process.
Notice text
The US Army Corps of Engineers, Walla Walla District is seeking sources to provide personnel, materials, supplies, equipment, transportation, supervision and other items and services for the following: McNary Powerhouse Turbine Draft Tube Slot Filler.
The North American Industry Classification System (NAICS) code for this project is 332312 (Fabricated Structural Metal Manufacturing) and the associated small business size standard is 500 employees.
This sources-sought announcement is a tool to identify businesses with the capability to accomplish the work. THIS IS NOT A SOLICITATION. Only those firms who respond to this announcement by submitting the following information will be used in determining whether to set aside this requirement.
a. A list of current or past projects demonstrating technical experience with work of a similar nature to that listed in the Bidder Requirements. For each project submitted, provide a brief narrative statement of the work involved, your firm’s role in the project, performance period, the dollar value and the completion date. Include a statement detailing any special qualifications and certifications, applicable to the scope of this project, held by your firm and/or in-house personnel.
b. A reference list for each of the projects submitted in a) above. Include the name, title, phone number and email address for each reference.
c. Provide a statement of your firm’s business size (HUBZone, Service Disabled Veteran Owned, 8(a), small disadvantaged, or woman-owned) with regards to the NAICS code listed above.
d. Provide a statement that your firm intends to submit an offer on the project when it is advertised.
e. Provide a statement of your firm’s bonding capacity. A statement from your surety is NOT required.
f. Cage Code and SAM Unique ID number.
Submit this information to Alan Inglis, Contract Specialist, via email to: Alan.n.Inglis@usace.army.mil
Summary of Scope of Work:
This project will include fabrication and delivery of 12 structural steel turbine draft tube slot fillers. This includes 6 sets, with each set containing one north and one south draft tube slot filler. The sets are mirrors of each other and are very similar structurally. Each draft tube slot filler uses welded ASTM A572 grade 50 structural steel plates, ASTM A1085 Hollow Structural Sections (HSS) steel, and has small UHMW components. Each slot filler is a picture frame shape approximately 35 ft wide, 20 feet tall, and 3 ft deep. There are 20 ft tall legs made from rectangular HSS as the sides to the picture frame shape. Each slot filler will weigh approximately 35,000 pounds, mostly consisting of steel. The first slot filler set requires an Epoxy Polysiloxane paint system and the remaining 5 sets require 5-E-Z vinyl paint. One test slot filler set will be delivered first. The test set will be installed, inspected, and tested by McNary project personal. If any design changes are needed, they will take place at this time. Once the test set is tested and any design changes are completed, the Contractor will be released to fabricate and deliver the remaining 5 sets.
Bidder Requirements:
1. The fabricating plant and fabricator is required to be certified under the AISC (American Institute of Steel Construction) Quality Certification Program with one of the following certifications:
- ABR: Certified Bridge Fabricator – Advance
- IBR: Certified Bridge Fabricator – Intermediate
- HYD: Certified Metal Hydraulic Fabricator
- BU: Certified Building Fabricator
The contractor must be certified prior to award of this contract and must remain certified for the duration of this contract. Submit copies of the AISC certificate(s) indicating that the fabrication plant meets the specified structural steelwork category.
1.1 In addition, the fabricator is required to have completed two projects of similar scope in the past ten years. Submit documentation for experience indicating that the fabrication plant has completed projects of similar scope as identified below.
Projects of similar scope consists of having fabricated structures with the following minimum requirements:
- Weight of 15-Tons or greater.
- Member thicknesses of 1/2-inch or greater.
- Length, width, or height of structure of at least 20-ft.
- Minimum tolerances of +/- 1/8-inch out of parallel over mat least 20-ft.
- Adequate crane capacity capable of picking and maneuvering the structures within fabrication building. Maneuvering the individual component includes any rotating about any axis of the structure that may be required for fabrication and weld distortion control.
2. The painting contractor must be certified by Association for Materials Protection and Performance (AAMP) with an SSPC QP 3 certification for all surface preparation and coating application. Submit a copy of the applicable certificates/endorsements. The contractor must be certified/endorsed prior to award of this contract and must remain certified/endorsed for the duration of this contract.
2.1 In addition, the painting contractor is required to have completed two projects of similar scope in the past ten years. Submit documentation for experience indicating that the painting contractor has completed projects of similar scope as identified below.
Projects of similar scope consists of having painted steel structures with the following minimum requirements:
- Application of USACE vinyl paint System No. 5-E-Z
- Surface preparation of SSPC SP 5.
Dimensions: See attached file (Draft Tube Slot Filler Dimension Drawing.pdf).
Files
| File | Type | Posted |
|---|---|---|
| Draft Tube Slot Filler Dimension Drawing.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Lower Monumental Diffuser Grating | ENDIST Walla Walla | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity