Market Intelligence Notice – Pre-Engineered Metal Buildings (PEMB)
Open Pre-Solicitation Posted
- Solicitation number
- W912HN26MIPEMB
- Agency
-
ENDIST Savannah
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- Not on record
- PSC
- Not on record
- Place of performance
- Savannah, Georgia 31401, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army Corps of Engineers, Savannah District is seeking market intelligence on industry capabilities for Pre-Engineered Metal Building construction on military installations, with responses due December 18, 2026 at 4:00 PM EST. No set-aside is used. This request for information is issued solely for information and planning purposes, does not constitute a solicitation or a commitment to issue one, and the Government will not pay response costs. Seven forecasted projects totaling approximately $323.2 million are identified as candidates for industrialized construction: Auto Multi-Purpose Machine Gun Range at Fort Bragg ($28 million); Guardian Angel Squadron Ops at Moody Air Force Base ($145 million); F-35A Flight Simulator ($67 million); F-35A Precision Guided Munitions ($35 million); F-35A Consolidated AGE Support Facility ($32 million); F-35A Egress Trainer ($8 million); and Live Fire Exercise Shoothouse at Fort Bragg ($8.2 million). Several projects include Secure and Special Access Program spaces requiring compliance with Intelligence Community Directive 705. Respondents must state whether each proposed feature is fully compatible with their standard commercial or industrialized building system, achievable with modifications, or better addressed through an alternative solution, and explain how alternatives serve the Government's schedule, cost, capacity/readiness, quality and durability, energy, repeatability/scalability, site impact, and compliance/turnover outcomes. Submissions require a completed online survey and a PDF capability statement covering corporate overview, commercial best practices, supply chain and logistics, and survey questions 12-16 (industrialized construction methods, collaborative delivery experience, design integration, and comparable SCIF/SAPF experience). Submit via the OSI survey link and by email to Jennifer.L.Murphy@usace.army.mil with copy to Sabrina.Bastine@usace.army.mil. Mark proprietary information clearly. The Government may use responses to assess potential use of 10 U.S.C. 2808a, Facility Construction or Repair: Transactions Other Than Contracts and Grants.
Notice text
Market Intelligence Notice – Pre-Engineered Metal Buildings (PEMB)
Disclaimer: This RFI is issued solely for information and planning purposes. It does not constitute a solicitation or a commitment to issue a solicitation in the future. The Government will not pay for any information or administrative costs incurred in response to this RFI.
1.0 Objective
The U.S. Army Corps of Engineers (USACE), Savannah District (SAS) is seeking market intelligence to identify and assess industry capabilities relevant to the construction of various facilities on military installations utilizing the Pre-Engineered Metal Building construction methodology. The Government is pursuing modern industrialized construction approaches intended to improve schedule, cost, and lifecycle outcomes for this facility type.
For purposes of this RFI, respondents should clearly identify whether they view these features as:
- Fully compatible with their standard commercial or industrialized building system;
- Achievable with modifications; or
- Better addressed through an alternative technical solution that provides equal or better performance.
Where respondents recommend alternatives, the response should explain how the proposed approach would satisfy or improve upon the Government's desired performance outcomes for schedule; cost; capacity/readiness; quality and durability; energy consumption; repeatability/scalability; site and installation impact; and compliance/turnover.
Information provided by respondents will be used to help the Government understand available market participants, solution types, and industry interest, and will inform future industry engagements, acquisition planning, and assessment of potential use of 10 U.S.C. § 2808a, Facility Construction or Repair: Transactions Other Than Contracts and Grants.
2.0 Forecasted Project(s) Overview
The projects identified below represent current candidates for industrialized construction methodologies across multiple military installations. This listing is non-exhaustive and subject to change. Solutions deployed under this initiative may be adapted and scaled across additional facilities as future requirements are defined. Note: Projects may include secure spaces.
Auto Multi-Purpose Machine Gun Range
Construct a modified standard design Multipurpose Machine Gun (MPMG) Range at Fort Bragg, North Carolina. Primary facilities include the MPMG Range, Range Control Tower, Range Operations and Storage Building, Range Classroom Building, Covered Mess, Ammunition Breakdown Building, Covered Bleacher, and building information systems. Supporting facilities include site improvements, paving, erosion control measures, electric service, and information systems. Facilities will be designed to a minimum life span of 40 years in accordance with Department of War’s (DoW) Unified Facilities Criteria (UFC 1-200-02), including energy efficiencies, building envelope and integrated building systems performance. Demolish 2 buildings at Fort Bragg, NC (459 Total ft2)
LFSHX - Live Fire Exercise Shoothouse
Construct standard design Live Fire Exercise Shoothouse. Primary facilities include the shoothouse, range operations control area, after action review building (small), operations/storage building (small), ammunition breakdown building, and latrine (aerated vault type). Supporting facilities include electric service, site improvements, and information systems. Access for persons with disabilities will be provided in the control and maintenance buildings. Air conditioning/heating: 4 tons. Supporting facilities cost is high due to the distance to the nearest utility hookups. Facilities will be designed to a minimum life span of 40 years in accordance with DoW's Unified Facilities Criteria (UFC 1-200- 02) including energy efficiencies, building envelope and integrated building systems performance.
38RQS Guardian Angel Squadron Ops
Construction of two new rescue squadron operations facilities, aircrew flight equipment facility, rescue maritime facility, open sided covered storage facility and an addition to the existing rescue squadron facility, building 663. Supporting facilities will include site preparations, site improvement, utilities, parking and walkways, landscaping, communications, allied support for modular buildings and all other work necessary for complete and usable facilities. Facility renovation of buildings 606 and 607 will include realignment of existing space, including work to interior walls, all utility/support systems including heating and cooling systems and fire detection and suppression systems. This Project also includes allied support construction for relocatable modular buildings to be used as swing space for the duration of construction, modular buildings include command and control, communication building, medical office, and portable armory unit.
F35A Flight Simulator
Construct a six-bay flight simulator facility for F-35A aircraft on Moody AFB. Facility will include space for 6 aircraft flight simulator bays, administration, records, classrooms, brief/debrief rooms, classified server room, and storage space for F-35A pilot flight simulator training. This facility will include Secure and Special Access Program spaces which must comply with the Intelligence Community Directive 705 criteria and standards. Supporting facilities will include demolition, site improvements, utilities, parking, and communications.
F35A Precision Guided Munitions
Construct Precision Guided Munition and Igloo Facilities at Moody AFB. Two Igloo facilities will be constructed with concrete headwall and precast, reinforced slabs on the top. Igloos are earth covered with earth fill surrounding the three closed sides with a 2:1 slide slope. The Igloo facilities will include motorized blast-proof steel doors, conduit infrastructure of Intrusion Detection System (IDS), lightning protection and grounding systems. Passive ventilation and floor drains are included for moisture. Sensitive and/or Special Access Program spaces shall comply with the Intelligence Community Directive 705 criteria and standards. Supporting facilities include utilities, access roads, pavement, parking, site improvements, communications infrastructure, signage, lighting, and unexploded ordnance clearance.
F35A Consolidated AGE Support Facility
Construct a new Aerospace Ground Equipment (AGE) consolidated facility to include administrative offices, parts storage, shop space, covered storage and open storage. This facility will include Secure and Special Access Program spaces which must comply with the Intelligence Community Directive 705 criteria and standards. Supporting facilities will include demolition, site improvements, landscaping, utilities, parking, and communications.
F35A Egress Trainer
Alter and renovate the internal space for the existing Field Training facility and construct an egress trainer. Alteration and renovation will include the addition of a bathroom and locker room, new carpet and paint, selective floor and ceiling replacement, and selective partition demolition. The addition will construct an attached egress trainer with a 21 feet ceiling height and a crane. Supporting facilities will include site improvements, utilities, and communications.
3.0 Requested Information & Market Intelligence Questionnaire
Section - General Information
Provide responses to the survey linked herein.
https://forms.osi.apps.mil/r/NX8GA8QFN5
Section - Capabilities
Respondents are asked to structure Capability Statements to include the following elements:
- Corporate Overview - A brief summary of your firm's core capabilities, relevant experience, and capacity to perform the type of work contemplated under this RFI.
- Commercial Best Practices. To the extent available, provide information regarding commercial best practices applicable to the contemplated construction delivery method, including:
- Typical pricing/payment structures
- Geographic coverage
- Typical project schedule timelines, long lead items, and key decision points
- Key considerations and risk associated with permitting, logistics, staffing/labor availability, and construction execution.
- Supply Chain and Logistics: Describe your supply chain for long lead items such as HVAC and electrical components; chillers, air handling units, computer room air conditioning (CRAC) units, transformers, etc. What are your typical lead times for material and fabrication?
- Survey Responses – Please provide detailed responses to Survey Questions 12 through 16 (listed below and on the survey form). Respondents are asked to integrate these responses directly into their capability statements; separate or stand-alone survey responses are not required. Additional Information – Respondents may include other information that demonstrates their relevant capabilities, experience, and capacity.
Survey Questions 12-16
12. How does your firm leverage industrialized construction (e.g., preassembly, modular cladding, or off-site fabrication) to accelerate on-site erection schedules and control quality?
13. Describe your firm’s practical experience with collaborative delivery models, such as Design-Build, Progressive Design-Build or Construction Manager at Risk (CMAR), where your team was integrated into the design phase. What specific pre-construction services did you provide?
14. For the projects listed in response to Q13, identify the major subcontractor(s) used and describe their qualifications. Detail the teaming relationship and contract structure between the construction contractor, the owner, and the Designer of Record. Explain how your team's involvement improved the final design quality, accelerated the delivery schedule, and reduced overall project cost.
15. How does your team fully coordinate and integrate structural, envelop, and utility designs between different interfacing construction types (such as stacked volumetric modules and traditional stick-built or foundation systems)? What engineering models do you utilize to analyze structural settlement or consolidation across these interfaces?
16. Describe up to three comparable Sensitive Compartmented Information Facility (SCIF) or Special Access Program Facility (SAPF) projects your proposed team has delivered. For each, identify—at an unclassified, releasable level—the facility type, scope, your contractual responsibilities, and which proposed personnel performed the work. What issues delayed design completion and construction completion, and what did you have to modify during construction?
4.0 Response Submission Instructions
- Format: Responses to the survey must be submitted via the link provided. The capability statement must be submitted in PDF format, single-spaced, using 11-point font or larger.
- Submission Deadline: December 18, 2026, 4:00 PM EST
- Submission Channel: Complete the survey at https://forms.osi.apps.mil/r/NX8GA8QFN5
- Submit capability statement via email to the Agreement Officer (AO) at Jennifer.L.Murphy@usace.army.mil and copy Sabrina.Bastine@usace.army.mil with the subject line: "USACE OTA Market Intelligence Response PEMB - [Company Name]".
- Proprietary Information: Any proprietary, sensitive, or business-confidential information must be clearly marked as such on each page to ensure proper handling by USACE SAS.
Files
| File | Type | Posted |
|---|---|---|
| Market Intelligence Notice PEMB.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Barracks Delivery Program | ENDIST Charleston | No set-aside | |
| Market Intelligence Notice - Ft. Belvoir, VA Bldg 1809 PDB | ENDIST Louisville | No set-aside | |
| FLW Renovate 3 SPRC Buildings | — | No set-aside | |
| Market Intelligence Notice: Fort Hood Bldg 410 General Stilwell Army Reserve Center (ARC) | ENDIST Louisville | No set-aside | |
| PKA Relocatable Facility | Global Strike Command | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity