Maintain and Repair Airfield Light Control System at Illesheim and Katterbach Airfields

Award Notice Posted

Solicitation number
W912PB15T3059
Agency
Awarded
to ADB Safegate Germany GMBH
Set-aside
No set-aside

Opportunity facts

Contract number
W912PB15P3090 Federal contract award
NAICS code
488119 Other Airport Operations
PSC
Not on record

Notice details come from SAM.gov. Updated .

Notice text

2 versions

Update #2 · Latest ·

The contractor shall provide services for maintenance and repair of Airfield Light Control system.
Katterbach Airfield
0001-Deliver & install new Minitower Computer for Visualization and Control of the Airfield Lighting (PI-Visualization) ready for use
0002-Deliver & install Power Supply unit for wiring isolation control device ready for use.
0003-Repair UCS300 Controller and ready to use reinstallation due to detected failure of blower fan.
0004-Deliver & install new UPS System ready to use as replacement for defective device.
0005-Maintenance of all CCR control Devices and PLS Systems to include all for the entire service related cost.

Illesheim Airfield
0006-Deliver & install new UPS System ready to use as replacement for defective device.
0007-Maintenance of all CCR control Devices and PLS Systems to include all for the entire service related cost.
0008-Deliver & install new Minitower Computer for Visualization and Control of the Airfield Lighting (PI-Visualization) ready for use.

For further information please see Performance Work Statement (PWS)

NOTE:

Solicitation has been amended to extend the solicitation closing date to 5:00 PM 27 APR 2015.

Update #1 ·

The contractor shall provide services for maintenance and repair of Airfield Light Control system.
Katterbach Airfield
0001-Deliver & install new Minitower Computer for Visualization and Control of the Airfield Lighting (PI-Visualization) ready for use
0002-Deliver & install Power Supply unit for wiring isolation control device ready for use.
0003-Repair UCS300 Controller and ready to use reinstallation due to detected failure of blower fan.
0004-Deliver & install new UPS System ready to use as replacement for defective device.
0005-Maintenance of all CCR control Devices and PLS Systems to include all for the entire service related cost.

Illesheim Airfield
0006-Deliver & install new UPS System ready to use as replacement for defective device.
0007-Maintenance of all CCR control Devices and PLS Systems to include all for the entire service related cost.
0008-Deliver & install new Minitower Computer for Visualization and Control of the Airfield Lighting (PI-Visualization) ready for use.

For further information please see Performance Work Statement (PWS)