Lock and Dam 12, Maintenace Building Roof Replacement, Bellevue, Iowa

Update #2 ·

The work shall consist of replacing the existing single sloped roof on the maintenance building at Lock & Dam 12. The building is approximately 2,016 sq ft. The existing roof is a 3 Ply built-up with a ballast topping. The contractor shall remove all ballast, 3 ply roof membrane, and insulation and dispose of properly in accordance with all applicable federal, state, and local laws. The contractor shall replace all plywood on the West side of the building. The replacement roof shall be an EPDM Rubber Membrane Roof with a minimum thickness of 60mils. The perimeter flashing is considered Asbestos Containing Material (ACM). The contractor shall submit an Asbestos Removal Plan for the removal and disposal of perimeter flashing.


It is anticipated that the solicitation and specifications will be available on www.fbo.gov on or about July 31, 2009.


All prospective offerors must have a Commercial and Government Entity (CAGE) Code and be actively registered in the Central Contractor Registion at www.ccr.gov.


Fascimilie quotes will not be accepted.  Contractors are encouraged to submit quotes through Army Single Face to Industry at https://acquisition.army.mil/asfi/


 


 

Update #1 ·

The work shall consist of replacing the existing single sloped roof on the maintenance building at Lock & Dam 12. The building is approximately 2,016 sq ft. The existing roof is a 3 Ply built-up with a ballast topping. The contractor shall remove all ballast, 3 ply roof membrane, and insulation and dispose of properly in accordance with all applicable federal, state, and local laws. The contractor shall replace all plywood on the West side of the building. The replacement roof shall be an EPDM Rubber Membrane Roof with a minimum thickness of 60mils. The perimeter flashing is considered Asbestos Containing Material (ACM). The contractor shall submit an Asbestos Removal Plan for the removal and disposal of perimeter flashing.